18
GB
Malfunctions
Possible causes
Remedy
Compressor becomes too hot
Oil level incorrect
Check oil level, top up oil if
necessary
Wrong oil type
Drain oil and replace with com-
pressor oil
Air filter dirty
Change air filter
Room temperature too high
Ensure that air supply is
or air supply is
adequate
inadequate
Compressor excessively
Check whether compressor is
overloaded
suitable for load
Note:
No claim is made to the completeness of the possible malfunctions listed here.
Technical data
The following is a table of performance values of individual compressor types (according to manufac-
turer specifications).
Model
Voltage
Power
Suction
Pressure
Tank
Noise
Weight
capacity
capacity
level
net
Volt
Watt
litre
bar
litre
dB (A) 1m
kg
20A
230/50
135
17
6
1,5
38
18
25A
230/50
135
17
6
3,5
38
16
HTC 30A
230/50
200
25
8
9
40
19
30A
230/50
200
25
8
4
40
19
HTC 50A
230/50
340
50
8
15
43
26
50A
230/50
340
50
8
24
43
29
100A
230/50
680
100
8
24
43
48
Subject to change and correction.