GENERAL INFORMATION



HARD Manufacturing cribs and youth beds are intended for use by patients up to 150lbs. 

It is strongly recommended to discourage parents or caregivers from getting into the crib or 
bed with the patient as it may cause premature wear or damage to various components.



The expected service life of all cribs and beds made by Hard Manufacturing is 9 years 

when preventative maintenance guidelines are followed.



HARD Manufacturing recommends the preventative maintenance checklist found at the 

end of this manual be performed at least once per year on each crib or bed in your facility. 
Cribs not meeting the criteria listed on the preventative maintenance checklist should be 
removed from service until they can be repaired as per the recommended guidelines.



HARD Manufacturing will support parts on our cribs and beds for up to 12 years from the 

date of manufacture as long as we still make the part or can obtain it from our vendors.



Cleaning instructions for all HARD Manufacturing cribs and beds can be found at the end 

of this manual. 

Failure to follow the proper cleaning instructions can result in 

premature rust and corrosion of the parts on your cribs.

To request a quote on replacement parts- please have either the serial # from the silver 
sticker located on the mattress platform, or the crib or bed model # and date of manufacture 
from the sticker on the bottom left side of the foot end available. Contact info is as follows:

Parts Manager
800-873-4273 x216
[email protected]

Please email or fax all parts orders to 716-896-2579 or [email protected]. If you do not 
receive an order con

fi

 rmation within one (1) business day, please resend the order until a 

con

fi

 rmation is received.

Con

fi

 dential document- for customer/end user only.

3

Содержание HI-LO 1813

Страница 1: ...Revised 2022 1 4 22 2022 MODELS 1813 1831 1842 1852 1873 STANDARD CRIB MANUAL HI LO SERVICE MANUAL The nations 1 manufacturer of hospital cribs 1 800 873 4273 parts hardmfg com...

Страница 2: ...acement Instructions Trigger Assembly for Rails or Johns Hopkins Handle Replacement Crank Handle Assembly Replacement 1904 IV Pole Assembly Diagram 1904 IV Pole Parts List IV Pole Installation Shelf B...

Страница 3: ...ARD Manufacturing will support parts on our cribs and beds for up to 12 years from the date of manufacture as long as we still make the part or can obtain it from our vendors Cleaning instructions for...

Страница 4: ...l is in place firmly and properly If the trigger mechanism for the side rail fails to lock into place properly remove the crib from service until the mechanism can be replaced SIDE RAIL OPERATION SAFE...

Страница 5: ...put stress on the crank handle components and eventually cause them to break THE HEAD CRANK HANDLE THE FOOT CRANK HANDLE The foot crank handle is located on the far right of the foot end of the crib...

Страница 6: ...of the Mattress Platform Assembly and cause a large amount of costly damage to that component The Hi Lo feature on Hard Manufacturing cribs will allow the height of the mattress platform to be raised...

Страница 7: ...17 Foot End Head End 1 2 3 4 5 6 11 12 13 18 Part Description Part Notes 1 Mattress Platform Assembly 1813 91160 Complete mattress platform Mattress Platform Assembly 1831 91599 Mattress Platform Asse...

Страница 8: ...rame Assembly 1842 89677 Bottom Frame Assembly 1852 89738 Bottom Frame Assembly 1873 89742 7 Tilt Indicator 63237 8 Corner Cover 11558 9 Hex Nut 10 32 63402 For Corner Covers 10 Screw 10 32x3 4 62048...

Страница 9: ...SIDE RAIL ASSEMBLY DIAGRAM 1 3 4 5 6 7 8 10 11 12 13 9 3 4 3 3 2 14 15 9...

Страница 10: ...TB 3 Glide Slide Bushing 11571 Nylon bushing with cutout 4 Bushing 11518 Solid nylon bushing 5 Johns Hopkins Handle Assembly 72115 Complete Handle Assembly Does not include Shield Plate 6 Screw 10 32...

Страница 11: ...n Part Notes 1 Head Assembly 30 wide crib 90278 Head Assembly 36 wide crib 90280 2 Foot Assembly 30 wide crib 90581 Foot Assembly 36 wide crib 90582 Teething Bars 1813 1913 TB Set of 4 not shown Prote...

Страница 12: ...For top of slide rod 5 Nylon Washer 11531 6 Slide Rod Inserts 11567 7 Slide Rod Adaptor 11576 Parts also available in hardware bag 72078 Parts for one slide rod 8 Plastic Washer 1 x 545 x1 8 11545 9 B...

Страница 13: ...ze the Johns Hopkins handle or the Fingertip Release mechanisms on the rail to disengage the trigger mechanisms while lifting the slide rod s up and out of the rail Disassembly is now complete SLIDE R...

Страница 14: ...ins handle or Fingertip Release to lock the rail in place 2 At the bottom of both of the slide rods put the spacer back on first then a washer the bumper spring and the other washer as shown on the pr...

Страница 15: ...trigger bracket inside the rail tube If only the Johns Hopkins Handle assembly is being replaced skip to Step 9 next It is necessary to remove the rail from the crib prior to the steps listed below P...

Страница 16: ...should be in the upright position as shown to the left SIDE TRIGGER ASSEMBLY OR JOHNS HOPKINS HANDLE REPLACEMENT CONTINUED Reassembly is now complete Tab 7 Take the black plastic center trigger brack...

Страница 17: ...l only put stress on the crank handle components and eventually cause them to break THE HEAD CRANK HANDLE THE FOOT CRANK HANDLE The foot crank handle is located on the far right of the foot end of the...

Страница 18: ...t of costly damage to that component The Hi Lo feature on the Springfield Cribs will allow the height of the mattress platform to be raised approximtely 10 to help prevent caregiver fatigue NOTE The M...

Страница 19: ...1904 IV POLE COMPONENT DIAGRAMS 15 1 2 3 4 5 6 4 5 7 8 9 10 11 12 13 14 Corresponding parts list is on the following page IV Pole Tube 19...

Страница 20: ...asher 2 11555 6 Plastic Spacer 1 62083 7 Release Pin 1 11852 8 Compression Spring 1 63006 9 Plastic Washer 1 11531 Used as release knob 10 Retaining Ring 1 63034 11 Plastic Bracket 2 11553 Available a...

Страница 21: ...l they lock together 5 Align the holes in the bracket and connector then tap in the two connector nuts 14 into the holes in both the top and bottom brackets connectors 6 Insert the two screws 13 into...

Страница 22: ...rib Shelf with O2 cut outs 1873 88166 1 2 Screw 1 4 20x5 8 63392 4 Used to attach shelf to bumper 3 Jam Nylon Locknut 1 4 20 63413 4 4 Washer 1 4 63443 4 5 Bumper Assembly 1813 1831 1842 84128 2 Assem...

Страница 23: ...di erent manner Please contact us for instructions in that situation Suggested Tools 60242 x 6 1 4 20 x 7 8 button socket cap screw 60245 x 6 1 4 20 connector nut 63413 x 4 Jam Nylon Locknut 63443 x 4...

Страница 24: ...the 4 screws 63392 4 locknuts 63413 and washers 63443 located in the 4 corners of the shelf as shown 2 Slide the shelf out of the crib through one of the ends as shown Remove Remove Remove Remove REP...

Страница 25: ...hich crib rests on and are bolted to Assembly is complete REPLACING OR INSTALLING AN UNDER CRIB SHELF OR BUMPER SYSTEM 4 Install the new bumper plate s by aligning the holes in the plate with the hole...

Страница 26: ...4 Bolt 8 8x10mm 61007 2 per caster 5 Casters Full set includes 1 Steer 2 Brake 1 Swivel 3 Caster Sockets BC 40 See Below This set of casters is on all hospital cribs manufactured prior to 2015 Steer...

Страница 27: ...s of these beds place them in the following categories To avoid overheating the motor after raising and lowering the bed three full times in successions HARD Manufacturing Company requires a fifteen m...

Страница 28: ...ressure washers of any kind Do not allow the crib or bed to air dry as pools of water left on the mattress pan surface or near bolt holes may eventually lead to premature corrosion CRIBS OR BEDS Mattr...

Страница 29: ...2020 2 0 Crib Safety Audit 2 1 Filler Bar Spacing Examine the spacing between bars of all cribs in service If a crib has railing spaces that exceed 2 3 8 remove it from service 2 2 Entrapment in cribs...

Страница 30: ...vers present on the top of the side rails 3 10 If the crib has Portland or Dialysis Gates in the side rails do the trigger assemblies retract and release Do the gates remain securely closed when tugge...

Страница 31: ...other damage 3 26 Is the under crib shelf securely fastened to the bumper system 3 27 Inspect the bumpers on both ends of the crib Are the grey corner bumpers present Are the other portions of the bum...

Страница 32: ...ould lead to premature corrosion and require replacement of the mattress Expected Service Life of HARD Manufacturing Cribs or Beds is 9 years Terms and Conditions of the Warranty Period The warranty c...