29
Door opening angle (0°
–
180°)
Door
closin
g angle (180°
–
10°)
Adjust the closing speed (valve 1) and locking force (valve 2) with the supplied hex key. Turn the nut
clockwise to reduce the closing speed. Do not turn the valves more than two turns anticlockwise from the
factory setting, this will cause leakage.
Adjusting the opening/closing force
Adjust the opening/closing force with the supplied hex key.
Increase/reduce the force
by turning the
set screw in the direction
shown in the diagram.