5. Set MIG Gun down on nonconductive,
nonflammable surface away from any grounded
objects. Turn the Power Switch ON.
6.
Settings -
Refer to Label on the
inside of the Welder door.
a. Auto (Synergic) Settings
–
Synergic
Indicator will light:
• Set Process
• Set Wire Diameter
Note:
If using 0.045" flux-cored wire, set Wire
Diameter to MANUAL. In this case, Synergic welding
will be turned off. Refer to Manual Settings below.
• Set Material Thickness
–
If Synergic
Indicator flashes, Material Thickness
setting is incorrect
–
refer to Settings
Chart for proper weld settings
b. Manual Settings:
• Set Process
• Set Wire Diameter to MANUAL
• Set Wire Feed Speed according
to Settings Chart
• Set Voltage according to Settings Chart
Note:
The initial settings may need to be
adjusted after stopping and carefully inspecting
the weld. Proper welding takes experience.
DANGER! TO PREVENT DEATH
FROM ASPHYXIATION:
Do not open gas without proper ventilation. Fix
gas leaks immediately.
Shielding gas can displace air and cause rapid loss of
consciousness and death.
Shielding gas without carbon dioxide can be even
more hazardous because asphyxiation can start
without feeling shortness of breath.
7.
Gas shielded, solid-core wire only:
a. Open gas cylinder valve all the way.
b. Set Flow Gauge to SCFH value
indicated on Settings Chart.
Power