problem

possible Causes

probable Solutions

Engine stops when 

under heavy load

1.  Dirty air filter.
2.  Engine running cold.

1.  Clean or replace element.
2.  Allow engine to warm up prior 

to operating equipment.

Engine misfires

1.  Spark plug cap loose.
2.  Incorrect spark plug gap or 

damaged spark plug.

3.  Defective spark plug cap.
4.  Old or low quality gasoline. 

 

 

5.  Incorrect compression.

1.  Check wire connections.
2.  Re-gap or replace spark plug. 

3.  Replace spark plug cap.
4.  Use only fresh 87+ octane stabilizer treated 

unleaded gasoline.

 

Do not use gasoline with more than 

10% ethanol (E15, E20, E85, etc.).

5.  Diagnose and repair compression. 

(Use 

Engine will not start: 

COMpRESSION RELATED

 section.)

Engine stops 

suddenly

1.  Carbon Monoxide level high.  Red light on 

Carbon Monoxide Sensor illuminates. 

2.  CO Sensor Alarm flashes yellow continually 

shortly after starting.  

 

3.  CO Sensor Alarm flashes yellow continually 

after longer period of operation.  

4.  Low oil shutdown. 

5.  Fuel tank empty or full of impure or low quality 

gasoline. 

 

6.  Defective fuel tank cap creating 

vacuum, preventing proper fuel flow.

7.  Faulty magneto.
8.  Disconnected or improperly 

connected spark plug cap.

1.  Leave area immediately and 

allow area to ventilate thoroughly.  

Only operate generator outside.

2.  Carbon monoxide sensor malfunction. 

Sensor needs service.  Call 1-888-866-5797 as 

soon as possible.  Do not use the Generator 

until the sensor is working properly.

3.  Make sure to operate generator within 

rated ambient temperature; maintain 

minimum 5 ft. clearance from all sides.

4.  Fill engine oil to proper level.  Check 

engine oil before EVERY use.

5.  Fill fuel tank with fresh 87+ octane stabilizer 

treated unleaded gasoline.

 

Do not use gasoline with more than 

10% ethanol (E15, E20, E85, etc.).

6.  Test/replace fuel tank cap. 

7.  Have qualified technician service magneto.
8.  Secure spark plug cap.

Engine knocks

1.  Old or low quality gasoline. 

 

 

2.  Engine overloaded.
3.  Incorrect spark timing, deposit buildup, worn 

engine, or other mechanical problems.

1.  Fill fuel tank with fresh 87+ octane stabilizer 

treated unleaded gasoline. 

  

Do not use gasoline with more than 

10% ethanol (E15, E20, E85, etc.).

2.  Do not exceed equipment’s load rating.
3.  Have qualified technician diagnose 

and service engine.

Engine backfires

1.  Impure or low quality gasoline. 

 

 

2.  Engine too cold. 

3.  Intake valve stuck or overheated engine. 

4.  Incorrect timing.

1.  Fill fuel tank with fresh 87+ octane stabilizer 

treated unleaded gasoline. 

  

Do not use gasoline with more than 

10% ethanol (E15, E20, E85, etc.).

2.  Use cold weather fuel and oil 

additives to prevent backfiring.

3.  Have qualified technician diagnose 

and service engine.

4.  Check engine timing.

Follow all safety precautions whenever diagnosing or servicing the equipment or engine.

Troubleshooting (continued)

Содержание PREDATOR 59134

Страница 1: ...nce 22g Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and window...

Страница 2: ...ken Access shall be through the use of a special tool or lock and key or other means of security and shall be controlled by the authority responsible for the location 2 Gasoline fuel and fumes are fla...

Страница 3: ...llow carbon monoxide to accumulate FLASHING RED LIGHT Dangerous levels of carbon monoxide gas have built up and generator will shutoff Leave immediately until area has aired out Move Generator to well...

Страница 4: ...placed f Press Reset button in for use The Generator must be grounded before use An ungrounded Generator has an increased risk of electric shock Refer to Grounding on page 9 19 Insulate all connection...

Страница 5: ...moving parts breakage of parts and any other condition that may affect the Generator s operation If damaged have the Generator serviced before using Many accidents are caused by poorly maintained equ...

Страница 6: ...rrectly 9 Store equipment out of the reach of children 10 Follow scheduled engine and equipment maintenance GFCI Protection This Generator is equipped with two 3 Prong duplex 120V ground fault circuit...

Страница 7: ...line Capacity 7 79 Gallon 29 50 Liter Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 Quart Spark Plug Type NHSP Torch F6TC Gap 0 028 0 031 Valve Clearance Intake 0 004 0 006 E...

Страница 8: ...ptacle 120 volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used ON OFF 3 Circuit Breakers The circuit breaker protects the...

Страница 9: ...intended to power sensitive electronic equipment without the addition of an appropriate line conditioner and surge protector both not included Sensitive electronic equipment includes but is not limite...

Страница 10: ...ns are as follows Use one of the following as the grounding electrode Pipe or conduit minimum in diameter minimum 8 ft long If steel it must have anti corrosion coating Rod stainless steel or copper o...

Страница 11: ...wl under the fuel cup to catch any spilled fuel 5 Unthread the screws holding the solenoid in place CAUTION Carburetor bowl may have gas in it which will leak upon removing the solenoid bolt 6 Disconn...

Страница 12: ...out threading it in and remove it to check the oil level The oil level should be up to the full level as shown above 5 If the oil level is at or below the low mark add the appropriate type of oil unti...

Страница 13: ...If above test fails do not use receptacle until it is repaired or replaced d Press Reset button in for use RESET TEST RESET TEST Reset Button Test Button 120 Volt GFCI Receptacle 4 Plug in products 5...

Страница 14: ...t the engine can stabilize For MANUAL START A Turn the Engine Switch to ON B Grip the Starter Handle of the Engine loosely and pull it slowly several times to allow the gasoline to flow into the Engin...

Страница 15: ...rated capacity for this Generator as serious damage to the Generator and or appliances tools and equipment could result from an overload Starting and running wattage requirements should always be cal...

Страница 16: ...r that only supplies the exact watts needed To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed...

Страница 17: ...gine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the Generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before turning off th...

Страница 18: ...qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment o...

Страница 19: ...Remove the drain plug and if possible tilt the crankcase slightly to help drain the oil out Recycle used oil 5 Replace the drain plug and tighten it 6 Clean the top of the Dipstick and the area around...

Страница 20: ...r back in place immediately after cleaning and before further operation Long Term Storage When the equipment is to remain idle for longer than 20 days prepare the Engine for storage as follows 1 CLEAN...

Страница 21: ...xposure to rain and sunlight NOTICE During extended storage periods the Engine must be started every 3 months and allowed to run for 15 20 minutes or the Warranty is VOID 6 AFTER STORAGE Before starti...

Страница 22: ...ilter IGNITION SPARK RELATED 1 Power Switch at OFF position 2 Spark plug cap not connected securely 3 Spark plug electrode wet or dirty 4 Incorrect spark plug gap 5 Spark plug cap broken 6 Circuit bre...

Страница 23: ...y operate generator outside 2 Carbon monoxide sensor malfunction Sensor needs service Call 1 888 866 5797 as soon as possible Do not use the Generator until the sensor is working properly 3 Make sure...

Страница 24: ...er Plug in product and turn on 3 Turn off and unplug product Test GFCI receptacle If functioning properly reset GFCI plug in product and turn on 4 Have product repaired Product begins to operate abnor...

Страница 25: ...TS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED T...

Страница 26: ...52 Muffler Vent Shield 1 53 Muffler Gasket 1 54 Flanged Hex Bolt 2 55 Tank Vibration Dampeners 4 56 Bushing 4 57 Flat Washer 4 Part Description Qty 58 Flanged Hex Bolt 4 59 Fuel Level Gauge 1 60 Phil...

Страница 27: ...ng Rod 1 137 Steel Cable Baffle Ring 2 138 Piston 1 139 Piston Pin 1 140 Piston Ring Assembly 1 141 Camshaft Assembly 1 142 Valve Lifter 2 Part Description Qty 143 Push Rod 2 144 Crankcase Body 1 145...

Страница 28: ...Page 28 For technical questions please call 1 888 866 5797 ITEM 59134 Safety Setup Operation Maintenance Assembly Diagram 1...

Страница 29: ...Page 29 For technical questions please call 1 888 866 5797 ITEM 59134 Safety Setup Operation Maintenance Assembly Diagram 2...

Страница 30: ...f Road Engine In California new equipment that uses small off road engines must be designed built and equipped to meet the State s stringent anti smog standards HFT must warrant that the emissions con...

Страница 31: ...shipping the product for repair 5 Notwithstanding the provisions herein warranty services or repairs will be provided at all retail stores or by contacting HFT product support at 1 888 866 5797 or pr...

Страница 32: ...26677 Agoura Road Calabasas CA 91302 1 888 866 5797...

Отзывы: