Item 63401 63402 
        

Specifications

63401

63402

Electrical Rating

120 VAC / 60 Hz / 1.3 A 120 VAC / 60 Hz / 2.45 A

Power Cord Length

16'

16'

Maximum Flow @ 0'

2500 GPH

4500 GPH

Maximum Head lift @ 0 Flow

19'

23'

Discharge Port

1/2" NPT Thread

2" NPT Thread

Installation

The submersible motor pump must be installed in a stationary position with either:

a.  A fixed pipeline or
b.  A flexible hose pipe.

6 FT. minimum

6 IN. minimum

1.  Submerge the pump under water to 

prevent the pump from taking in air.

2.  The pond must be at least 6 feet 

away from the receptacle.

3.  To reduce wear on the pump, place the 

pump on a platform above mud, sand, 
small rocks, and other debris.

4.  If running with fountain jets, the pump must be 

mounted firmly and horizontally on a platform.

5.  Connect a discharge hose (not included) 

to the Hose Adapter (3).

6.  Connect the free end of the discharge hose to a 

waterfall basin, or similar device (none included).

Please note!

1.  Do not install the pump by suspending it 

unsupported from its delivery pipe or power cord.  
The pump must be suspended from the handle 
or be placed on the bottom of the basin.  
To ensure that the pump works properly, keep the 
bottom free from sludge and dirt of all kinds.

2.  If the water level sinks too low, any sludge in the 

basin will dry out and stop the pump from starting.  
To help ensure the pump will start as required, 
check the pump regularly with start-up tests. 

Power Supply

1.  The Pump is equipped with a shock-

proof plug according to regulations.  The 
Pump is designed to be connected to a 

120 VAC, 60 Hz GFCI protected socket.

2.  Make sure that the socket is sufficiently 

secured and is in excellent condition.

3.  When the plug is inserted into the socket, 

the pump will be on standby.

4. 

WARNING: To prevent death from electric 
shock, pump must be connected only to 
a GFCI protected outlet.

WARNING!

 If the power cord or plug is damaged, 

do not use the pump.  The power cord or plug 
may only be repaired by a certified electrician.

WARNING!

 Pump must be positioned with a 

drip loop, as discussed under WARNING.

Areas of use

1.  This pump is designed to pump fresh water only.

2.  This pump is designed to be used for:

An area not used for swimming.

Содержание creekstone 63402

Страница 1: ...eference 17j When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2016 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this ma...

Страница 2: ...lf contained fountains 10 POSITION OF PUMP To avoid the possibility of the pump plug or receptacle getting wet position pump to one side of a wall mounted receptacle to prevent water from dripping onto the receptacle or plug The user should arrange a drip loop in the cord connecting the pump to a receptacle Pump The drip loop is that part of the cord below the level of the receptacle or the connec...

Страница 3: ...ding it unsupported from its delivery pipe or power cord The pump must be suspended from the handle or be placed on the bottom of the basin To ensure that the pump works properly keep the bottom free from sludge and dirt of all kinds 2 If the water level sinks too low any sludge in the basin will dry out and stop the pump from starting To help ensure the pump will start as required check the pump ...

Страница 4: ...spended by the handle 2 Verify that the discharge pipe is properly connected 3 Verify that the electrical connection is 120VAC 60Hz 4 Verify that the electrical socket is GFCI protected and in good condition Test GFCI protected outlet before use 5 Verify that water and moisture cannot get near the power supply socket 6 Verify that the pump is installed so as to prevent running dry The inlet or top...

Страница 5: ...t Screen 2 For proper operation after startup Pump must remain completely submerged at all times 3 Consult an electrician 4 Remove and examine check valve Pump won t start or run 1 Check power connections and circuits fuses 2 Water level too low 3 Filter Inlet Screen and or impeller clogged 4 Defective motor 5 Cord not connected 6 Pump discharge or hose kinked or obstructed 7 Impeller broken or ja...

Страница 6: ...CENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Parts List Part Description Qty 1 Front Cover 1 2 Connector 1 3 Pump House 1 4 Sealing Ring 1 5 Impeller 1 6 Rotor 1 7 Screws 4 8 Pump Holder 1 9 Pump Body 1 Par...

Страница 7: ...Page 7 For technical questions please call 1 888 866 5797 Item 63401 63402 Assembly Diagram 3 4 5 8 9 15 2 7 1 10 11 12 14 6 17 13 16 ...

Страница 8: ...so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If o...

Отзывы: