background image

Page 7

SKU 97728

For technical questions, please call 1-800-444-3353.

UnpAckIng

When unpacking, check to make sure 

that the item is intact and undamaged.  If 

any parts are missing or broken, please 

call Harbor Freight Tools at the number 

shown throughout the manual as soon as 

possible.

This air tool may be shipped with a 

• 

protective plug covering the air inlet.  

Remove this plug before set up.

TOOl SET Up & ASSEMblY

Read the EnTIRE IMpORTAnT 

SAFETY InFORMATIOn 

section at the beginning of this 

manual including all text under 

subheadings therein before set 

up or use of this product.

note:

  For additional information regarding 

the parts listed in the following pages, 

refer to the Assembly Diagram near 

the end of this manual.

components and controls

Assembly

A male Quick Connector (not 

1. 

included) must be installed prior to 

operating the Air Router.  To do so:

Wrap about three inches of pipe 

• 

thread sealer tape (not included) 

around the threads of the Quick 

Connector.  Then screw the Quick 

Connector firmly into the Air Inlet 

(14) of the tool.  

(See Figure A.)

To install a 1/4” Router Bit (not 

2. 

included) into the Air Router:

Firmly grasp the Housing (1) and 

• 

the Housing Cap (30), turning them 

in opposite directions.  Completely 

unwind and separate the two items.
Use the 3/4” Spanner Wrench (34) 

• 

and 9/16” Spanner Wrench (35) to 

loosen the Collet Nut (29).
Insert the Router Bit fully into the 

• 

Collet (28).
Firmly tighten the Collet Nut, 

• 

using the Spanner Wrenches. 

(See Figure b.)

 

RETAInER (26)

cOllET (28)

cOllET nUT (29)

3/4”

SpAnnER

WREncH

(34)

9/16””

SpAnnER

WREncH

(35)

FIgURE b

Содержание Central Pneumatic 97728

Страница 1: ...ssion Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury Save this manual Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight...

Страница 2: ...avoided could result in death or serious injury CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address practices not related to personal injury IMPORTANT SAFETY INSTRUCTIONS Instructions Pertai...

Страница 3: ... at all times Proper footing and balance enables better control of the tool in unexpected situations f Use safety equipment A dust mask non skid safety shoes and a hard hat must be used for the applicable conditions Wear heavy duty work gloves during use g Always wear eye protection Wear ANSI approved safety goggles h Always wear hearing protection when using the tool Prolonged exposure to high in...

Страница 4: ...tool s operation If dam aged have the tool serviced before using Many accidents are caused by poorly maintained tools There is a risk of bursting if the tool is damaged Use only accessories that are j identified by the manufacturer for the specific tool model Use of an accessory not intended for use with the specific tool model increases the risk of injury to people Service Tool service must be pe...

Страница 5: ...or WARNING 2 Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Some examples of these chemicals are Lead from lead based paints Crystalline silica from bricks and cement or other masonry products Arsenic and chromium from chemically treated lumber...

Страница 6: ...to the hand past hand injuries nervous system disorders diabetes or Raynaud s Disease should not use this tool If you feel any medical or physical symptoms related to vibration such as tingling numbness and white or blue fingers seek medical advice as soon as possible Do not smoke during use Nicotine 2 reduces the blood supply to the hands and fingers increasing the risk of vibration related injur...

Страница 7: ...r to the Assembly Diagram near the end of this manual Components and Controls Assembly A male Quick Connector not 1 included must be installed prior to operating the Air Router To do so Wrap about three inches of pipe thread sealer tape not included around the threads of the Quick Connector Then screw the Quick Connector firmly into the Air Inlet 14 of the tool See Figure A To install a 1 4 Router...

Страница 8: ...of Pneumatic Tool Oil DAILY into the tool s male Quick Coupler before operation See Figure A Attach an air hose to the 2 compressor s air outlet Connect the air hose to the air inlet of the tool Other components such as a connector and quick coupler will make operation more efficient but are not mandatory WARNING To prevent serious injury from accidental operation Do not install a female quick cou...

Страница 9: ...et Up Designate a work area that is clean 1 and well lit The work area must not allow access by children or pets to prevent injury and distraction Route the air hose along a safe 2 route to reach the work area without creating a tripping hazard or exposing the air hose to possible damage The air hose must be long enough to reach the work area with enough extra length to allow free movement while w...

Страница 10: ...t maximum pressure and sufficient airflow then a larger tool will be required When finished routing remove Air 9 Router away from work piece and release pressure on the Trigger 3 to stop the Air Router Wait until the Router Bit stops rotating then set the tool down See Figure A To prevent accidents detach the air 10 supply safely discharge any residual air pressure in the tool and release the Trig...

Страница 11: ...operation of the air operated tool Daily Air Supply Maintenance 1 Everyday perform maintenance on the air supply according to the component manufacturers instructions The lubricator s oil level needs to be maintained and the moisture filter must be regularly drained Performing routine maintenance on the air supply will allow the tool to operate more safely and will also reduce wear on the tool Dai...

Страница 12: ...re air leakage Slight air leakage is normal especially on older tools Cross threaded housing 1 components Loose housing 2 Damaged valve or housing 3 Dirty worn or damaged valve 4 Check for incorrect alignment and uneven 1 gaps If cross threaded disassemble and replace damaged parts before use Tighten housing assembly If housing cannot 2 be tightened properly internal parts may be misaligned Replac...

Страница 13: ...gulator 1 10 O Ring 1 11 O Ring 1 12 Valve Plug 1 13 Muffle Cover 1 14 Air Inlet with screen 1 15 Bearing 1 16 End Plate 1 17 Steel Ball 2 18 Rotor 1 19 Rotor Blade 4 20 Cylinder 1 21 Bushing 1 22 Front Plate 1 23 Pin 1 24 Bearing 1 25 Collet Holder 1 26 Retainer 1 27 Housing Cap 1 28 Collet 1 29 Collet Nut 1 30 Housing Cap 1 31 Lock Nut 1 32 Router Base 1 33 Router Guide 1 34 3 4 Spanner Wrench 1...

Страница 14: ...ranty is expressly in lieu of all other warranties express or implied including the warranties of merchantability and fitness To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If our inspection verifies the defect we will either repair or replace...

Отзывы: