Harbor Breeze TG52BNK3D1RC Скачать руководство пользователя страница 19

19

                    

A

B

C

Printed in China

REPLACEMENT PARTS LIST

For replacement parts, call our customer service department at 

1-800-643-0067

, 8 a.m. - 6 p.m., EST, 

Monday - Thursday,  8 a.m. - 5 p.m., EST, Friday.

PWLI1807

The distributor warrants this fan to be free from defects in workmanship and materials present at time 
of shipment from the factory for Lifetime limited from the date of purchase.  This warranty applies only 
to the original purchaser. The distributor agrees to correct any defect at no charge or, at our option, 
replace the ceiling fan with a comparable or superior model.

To obtain warranty service, present a copy of your sales receipt as proof of purchase.  All cost of 
removal and reinstallation are the express responsibility of the purchaser.  Any damage to the ceiling 
fan by accident, misuse or improper installation, or by using parts not produced by the manufacturer 
of this fan or affixing accessories not produced by the manufacturer of this fan, are the purchaser's 
own responsibility.  The distributor assumes no responsibility whatsoever for fan installation during 
the limited lifetime warranty.  Any service performed by an unauthorized person will render the 
warranty invalid.

Due to varying climatic conditions, this warranty does not cover changes in brass finish, rusting, 
pitting, tarnishing, corroding or peeling.  Brass finish fans maintain their beauty when protected from 
varying weather conditions.  Any glass provided with this fan is not covered by the warranty.

Any replacement of defective parts for the ceiling fan must be reported within the first year from the 
date of purchase.  For the balance of the warranty, call our customer service department (

at 

1-800-643-0067

)

 for return authorization and shipping instructions so that we may repair or replace 

the ceiling fan.  Any fan or parts returned improperly packaged is/are the sole responsibility of the 
purchaser.  There is no further express warranty.  The distributor disclaims any and all implied 
warranties.  The duration of any implied warranty which cannot be disclaimed is limited to the limited 
lifetime period as specified in our warranty.  The distributor shall not be liable for incidental, 
consequential or special damages arising at or in connection with product use or performance except 
as may otherwise be accorded by law.  This warranty gives you specific legal rights and you may also 
have other rights which vary from state to state.  This warranty supersedes all prior warranties.

LIMITED LIFETIME WARRANTY

J

    PART         DESCRIPTION 

       

A      Downrod

       

B      Canopy

       

C      Mounting Bracket

       J      Blade

0883810-A
0883810-B
0883810-C
0883810-J

#

0883810

    #

0883809

PART #          PART #         

0883809

-A

0883809

-B

0883809

-C

0883809

-J

Содержание TG52BNK3D1RC

Страница 1: ...ATTACH YOUR RECEIPT HERE Purchase Date Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday 1 Harbor Breeze is a registered trademark of LF LLC All Rights Reserved PH18481 ...

Страница 2: ...it must be shipped in its original packaging to ensure proper protection against damage that might exceed the initial cause for return Make sure all electrical connections comply with local codes ordinances the National Electrical Code and ANSI NFPA 70 1999 Hire a qualified electrician or consult a do it yourself wiring handbook if you are unfamiliar with installing electrical wiring Make sure the...

Страница 3: ...sponding fan lead wires consult an electrician for the proper size wire connectors to use To reduce the risk of fire or electrical shock do not use the fan with any solid state speed control device or control fan speed with a full range dimmer switch To reduce the risk of fire electrical shock or personal injury do not bend the blades when installing or balancing them or cleaning the fan Do not in...

Страница 4: ...nting Screw 4 preassembled H Motor Screw 6 preassembled I Lock Washer preassembled 6 J Blade 3 DESCRIPTION PART QUANTITY DESCRIPTION PART QUANTITY K Glass Shade 1 L Pin preassembled 1 M Clip preassembled 1 N Balancing Kit 1 O Remote Control Receiver 1 P Remote Pack 1 IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety N P ...

Страница 5: ...ols Required for Assembly not included Electrical Tape Phillips Screwdriver Pliers Safety Glasses Stepladder and Wire Strippers Helpful Tools not included AC Tester Light Tape Measure Do It Yourself Wiring Handbook and Wire Cutters PREPARATION Fiber Blade Washer Qty 9 1 extra CC Blade Screw Qty 9 1 extra Wire Connector Qty 4 AA BB CC INITIAL INSTALLATION ON OFF ON OFF 1 Turn off circuit breakers a...

Страница 6: ...cluded Angle style mounting is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensure proper blade clearance Closemount mounting is more suitable for ceilings lower than 8 ft high Check to make sure blades J will be at least 30 in from any obstruction and at least 7 ft above the floor 3 4 Temporarily raise canopy B to mounting bracket C and determine which 2 c...

Страница 7: ...h holes in blade arm located inside of motor Attach blade J with 3 blade screws AA and fiber washers BB Repeat for remaining blades J Note Make sure to completely secure each blade J before proceeding to the next 6 7 Reattach top plate and yoke plate to motor housing D with lock washers I and motor screws H previously removed in Step 5 Hardware Used Blade Screw x 9 AA Fiber Blade Washer x 9 BB 5 t...

Страница 8: ...TANT If using the angle mount make sure open end of mounting bracket C is installed facing the higher point of the ceiling and ensure the ceiling angle is not steeper than 19 8 For DOWNROD STYLE FAN MOUNTING proceed to step 1 below For CLOSEMOUNT STYLE FAN MOUNTING skip to page 10 Remove pin L and clip M from downrod A Partially loosen preassembled set screws and nuts in yoke at top of motor housi...

Страница 9: ...manner Take the lead wires and make sure you have pulled them all the way through the top of the downrod Start at the TOP of the hanging ball on the downrod and measure 8 in of lead wire and then cut the excess wire off with wire cutters not included NOTE If you do not cut back the lead wires Steps 4 and 5 are not necessary and you may proceed to Step 6 instead E Slip downrod A into yoke align hol...

Страница 10: ...s in Step 4 strip 1 2 in of insulation from end of each wire WHITE BLACK GREEN and BLUE Twist stripped ends of each strand of wire within the insulation with pliers not included Install hanging ball of downrod A into opening of mounting bracket C Align one of the slots in hanging ball with the tab in mounting bracket C DANGER Failure to align slot in hanging ball with the tab in mounting bracket C...

Страница 11: ...B D Remove every other motor screw H and lock washer I from top of motor housing D 2 Pull wires up through hole in the middle of the canopy B Align larger holes in canopy B with 3 screws in top of motor housing D Attach canopy B to motor housing D using the three motor screws H and lock washers I previously removed H I 2 D D H I Tab C 4 B Non Slotted ...

Страница 12: ...nections for remote control operation as detailed below and in the figure For each wire connection use one of the wire connectors CC making sure to screw wire connector CC on in a clockwise direction CAUTION Assistance from another person is recommended for this step Connect all GROUND GREEN wires from fan on downrod A if applicable and mounting bracket C to BARE GREEN supply wire from ceiling Con...

Страница 13: ...or x 4 CC 3 Gently slide remote control receiver O flat side up into mounting bracket C Turn spliced taped wires upward and gently push wires and wire connectors CC into outlet box Let antenna from remote control receiver O hang to the side NOTE The remote control included with this fan meets the following requirements a Not for use with solid state fans b Electrical rating 120V 60 Hz motor amps 1...

Страница 14: ...ion Closemount Option 2 Align slots on glass shade K with protrusions on underside of motor housing D Turn glass shade K clockwise until it no longer turns NOTE Pull down gently on the glass shade K to make sure it is secured completely 3 Remote Control Bracket Wall 3 If you wish to use the remote control bracket from remote pack P install screws from remote pack P through bracket and into the des...

Страница 15: ...ined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technic...

Страница 16: ...r fan MEDIUM speed 1 button for fan LOW speed 0 button to turn fan OFF button to turn light ON or OFF Tap button quickly to turn lights off or on Hold button down to increase or decrease lights If you press button in excess of 0 7 seconds it becomes a dimmer The lights vary cyclically in 8 seconds The light button has an auto resume function which keeps the light at the same brightness as the last...

Страница 17: ...ng the reverse switch in the RIGHT position will result in upward airflow that can help move stagnant hot air off the ceiling area At least twice each year lower canopy B to check downrod A assembly and then tighten all screws on fan Clean motor housing D with only a soft brush or lint free cloth to avoid scratching the finish Clean blades J with a lint free cloth You may occasionally apply a ligh...

Страница 18: ...d speed control device 4 Allow fan a break in period of a few days especially when running the fan at Medium and High speeds Excessive wobbling 1 Blades are loose 2 Unbalanced blades 3 Fan not securely mounted 4 Fan too close to vaulted ceiling 5 Set screw s on motor housing yoke is are not tightened properly 1 Tighten all blade screws 2 Switch one blade with a blade from the opposite side or use ...

Страница 19: ...nty does not cover changes in brass finish rusting pitting tarnishing corroding or peeling Brass finish fans maintain their beauty when protected from varying weather conditions Any glass provided with this fan is not covered by the warranty Any replacement of defective parts for the ceiling fan must be reported within the first year from the date of purchase For the balance of the warranty call o...

Отзывы: