background image

11

Connect all GROUND (GREEN) wires from fan 

(on downrod (A), if applicable, mounting 

bracket (C)) and remote control receiver (Q) to 

BARE/GREEN supply wire from ceiling.

Connect BLACK wire (labeled AC IN L) from remote 

control receiver (Q) to BLACK supply wire from 

ceiling.

Connect WHITE wire (labeled AC IN N) from remote 

control receiver (Q) to WHITE supply wire from 

ceiling.

Connect RED wire (labeled TO MOTOR) from 

remote control receiver (Q) to RED wire from motor 

housing (D).

Connect GRAY wire (labeled TO MOTOR) from 

remote control receiver (Q) to GRAY wire from motor 

housing (D).

Connect PINK wire (labeled FOR MOTOR) from 

remote control receiver (Q) to PINK wire from motor 

housing (D).

Connect BLUE wire (labeled FOR LIGHT L) from 

remote control receiver (Q) to BLUE wire from motor 

housing (D).

Connect WHITE wire (labeled FOR LIGHT N) from 

remote control receiver (Q) to WHITE wire from motor 

housing (D).

 1.

WIRING

Q

1

WHITE SUPPLY WIRE

BLACK SUPPLY WIRE

PINK

RED

RED

GRAY

GRAY

PINK

WHITE

BLUE

BLUE

WHITE

BLACK

AC IN L

WHITE

AC IN N

WHITE

GROUND (GREEN OR BARE)

GROUND 

(GREEN OR BARE)

BLACK

FROM

RECEIVER

FROM 

FAN

FROM

RECEIVER

FROM

CEILING

A

C

GREEN/

GROUND

       

WARNING:

 To reduce the risk of fire, electrical shock or personal injury, wire connectors provided 

with this fan are designed to accept only one 12-gauge house wire and two lead wires from the fan. If 
your house wire is larger than 12-gauge or there is more than one house wire to connect to the 
corresponding fan lead wires, consult an electrician for the proper size wire connectors to use.

       

CAUTION:

 Be sure outlet box is properly grounded and that a ground (green or bare) wire is present.

       

WARNING:

 If house wires are different colors than referred to in the following steps, stop immediately. 

A professional electrician is recommended to determine wiring.

       

WARNING:

 Using a full range dimmer switch (not included) to control fan speed will cause a loud 

humming noise from fan. To reduce the risk of fire or electrical shock, do NOT use a full range dimmer switch 
to control fan speed.

IMPORTANT

: Make the necessary wiring connections for 

remote control operation as detailed on next page. For each 
wire connection, use one of the wire connectors from the 
remote pack (R), making sure to screw wire connector on in 
a clockwise direction.

Wire 

Connectors

R

Содержание TALAMORE TAL60BNK8LR

Страница 1: ...Espa ol p 20 MODEL TAL60BNK8LR ATTACH YOUR RECEIPT HERE Purchase Date 1 4007498 Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 527 129...

Страница 2: ...ent The equipment refers to the remote control transmittor and or LED light kit This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device ma...

Страница 3: ...reduce the risk of fire electrical shock or personal injury wire connectors provided with this fan are designed to accept only one 12 gauge house wire and two lead wires from the fan If your house wi...

Страница 4: ...1 G Canopy Mounting Screw 4 preassembled H Fitter Plate 1 I Fitter Plate Screw 3 preassembled J Blade 8 DESCRIPTION PART QUANTITY DESCRIPTION PART QUANTITY K Motor Plate Screw 3 preassembled L Blade A...

Страница 5: ...quired for Assembly not included Electrical Tape Phillips Screwdriver Pliers Safety Glasses Stepladder and Wire Strippers Helpful Tools not included AC Tester Light Tape Measure Do It Yourself Wiring...

Страница 6: ...ecessary to ensure proper blade clearance Closemount mounting is more suitable for ceilings lower than 8 ft high Check to make sure blades J will be at least 30 in from any obstruction and at least 7...

Страница 7: ...tor Block S Remove motor screw washers S from underside of motor housing D and save for blade arm attachment later on If there are plastic motor blocks installed with the motor screws washers S discar...

Страница 8: ...8 in of lead wire and then cut the excess wire off with wire cutters not included NOTE If you do not cut back the lead wires Steps 4 and 5 are not necessary and you may proceed to Step 6 instead E Sli...

Страница 9: ...to WIRING on page 11 C Tab 6 A Slot 2 D Screw Lock Washer Remove every other preassembled screw and lock washer from top of motor housing D Remove preassembled canopy cover P from bottom of canopy C N...

Страница 10: ...ounting bracket C using one of the non slotted holes in the canopy B 3 3 Non Slotted Tab C 3 B Pull wires up through hole in the middle of the canopy B and attach canopy B to motor housing D using the...

Страница 11: ...UND GREEN OR BARE BLACK FROM RECEIVER FROM FAN FROM RECEIVER FROM CEILING A C GREEN GROUND WARNING To reduce the risk of fire electrical shock or personal injury wire connectors provided with this fan...

Страница 12: ...wire WARNING Make sure no bare wire or wire strands are visible after making connections Place GREEN and WHITE connections on opposite side of the outlet box from the BLACK and BLUE if applicable con...

Страница 13: ...usly removed Step 5 page 7 Insert two motor screws washers S through one blade arm L to attach blade arm L to motor housing D Tighten motor screws washers S securely Repeat with remaining blade arms L...

Страница 14: ...t F to BLUE or BLACK wire from motor housing D Make sure molex connections are secure F 6 WHITE BLUE or BLACK WHITE BLUE D H 7 Carefully arrange wiring within the fitter plate H to ensure wires do not...

Страница 15: ...drill two pilot holes in drywall at marked locations Position plastic anchor in each pilot hole Gently tap plastic anchors with a hammer not included until flush with wall surface Screw bracket screws...

Страница 16: ...arty responsible for compliance could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this...

Страница 17: ...e light kit for 5 minutes every 2 hours Color mode change select light color warm white bright warm white natural white bright white daylight 3 1 2 4 5 6 7 8 OPERATING INSTRUCTIONS Tap button quickly...

Страница 18: ...securely mounted 4 Fan too close to vaulted ceiling 5 Set screw on motor housing yoke is not tightened properly 6 Set screw on hanging ball is not tightened properly 1 Tighten all blade screws 2 Swit...

Страница 19: ...fans maintain their beauty when protected from varying weather conditions Any glass provided with this fan is not covered by the warranty Any replacement of defective parts for the ceiling fan must be...

Отзывы: