background image

SAFETY INFORMATION

3

WARNING

           

To reduce the risk of fire, electrical shock or personal injury, mount fan to outlet box

            marked "ACCEPTABLE FOR FAN SUPPORT OF 35 LBS. OR LESS" and use
            mounting screws provided with the outlet box. Most outlet boxes commonly used for the 
support of lighting fixtures are not acceptable for fan support and may need to be replaced. 
Consult a qualified electrician if in doubt. 
 
When mounting fan to a ceiling outlet box, use a METAL octagonal outlet box; do NOT use a 
plastic outlet box. Secure the outlet box directly to the building structure. The outlet box and its 
support must be able to support the moving weight of the fan (at least 35 lbs.). 
 
To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp 
edges.
 
To reduce the risk of fire, electrical shock or personal injury, wire connectors provided with this 
fan are designed to accept only one 12-gauge house wire and two lead wires from the fan. If 
your house wire is larger than 12-gauge or there is more than one house wire to connect to the  
corresponding fan lead wires, consult an electrician for the proper size wire connectors to use.
 
To reduce the risk of fire or electrical shock, do not use the fan with any solid state speed control 
device or control fan speed with a full range dimmer switch.
 
To reduce the risk of fire, electrical shock or personal injury, do not bend the blades when 
installing or balancing them, or cleaning the fan. Do not insert objects between the rotating fan 
blades.
 

To reduce the risk of personal injury, use 

only

 parts provided with this fan. The use of parts 

OTHER 

than those provided with this fan will void the warranty.

 

Before proceeding, be sure to shut off electricity at main switch or circuit breaker in order to 
avoid electrical shock.

WARNING

  

Be sure outlet box is properly grounded and that a ground wire (green or bare) is present.
 

Before beginning installation, carefully check all screws, bolts and nuts on fan motor assembly to 
ensure that they are secured.

 

Do NOT tamper with or attempt to repair LED component. The light source is designed for this 
specific application and should not be serviced by untrained personnel. If any servicing is 
required, call our customer service department.

CAUTION

Содержание FAIRWIND

Страница 1: ...LW3LRS Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 527 1292 8 30 a m 5 p m CST Monday Friday ATTACH YOUR RECEIPT HERE Serial Number...

Страница 2: ...30 in from the end of the blades to any obstruction After you install the fan make sure all connections are secure to prevent the fan from falling The net weight of this fan including the light kit is...

Страница 3: ...ne house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use To reduce the risk of fire or electrical shock do not use the fan with an...

Страница 4: ...Cover 1 F Light Kit Fitter 1 G Blade 3 H Canopy Cover 1 I Glass Shade 1 J Blade Plate 3 DESCRIPTION PART QUANTITY PACKAGE CONTENTS 4 E N O DESCRIPTION PART QUANTITY K Canopy Mounting Screw 2 preassemb...

Страница 5: ...e contents list If any part is missing or damaged do not attempt to install operate or assemble the product Estimated Assembly Time 120 minutes Tools Required for Assembly not included Electrical Tape...

Страница 6: ...eiling angle is not steeper than 19 Helpful Hint Downrod style mounting is best suited for ceilings 8 ft high or higher For taller ceilings you may want to use a longer downrod not included Angle styl...

Страница 7: ...en thread wires from motor housing D through downrod A 6 B E A H 4 Open End 4 C C ANGLE MOUNT STANDARD MOUNT Secure mounting bracket C to outlet box not included using screws spring washers and flat w...

Страница 8: ...E If you do not cut back the lead wires Steps 8 and 9 are not necessary and you may proceed to Step 10 instead 8 7 Slip downrod A into motor housing yoke align holes and re install pin L and clip M Ti...

Страница 9: ...s to use CAUTION Be sure outlet box is properly grounded and that a ground green or bare wire is present WARNING If house wires are different colors than referred to in the following steps stop immedi...

Страница 10: ...ose to use a different remote control with this fan it must also meet these same requirements 3 Antenna A R C 1 Connect all GROUND GREEN wires from fan on downrod A if applicable and mounting bracket...

Страница 11: ...proceeding 11 FINAL INSTALLATION 2 2 G J D BB Hardware Used Blade Screw Washer x 6 BB Locate two canopy mounting screws K on underside of mounting bracket C and remove canopy mounting screw K closest...

Страница 12: ...te screw O Align slotted holes in fitter plate N with loosened motor plate screws O allowing molex connections from motor housing D to come through hole in fitter plate N Twist fitter plate N to lock...

Страница 13: ...o ensure wires do not get pinched when attaching the light kit fitter F Align slotted holes in light kit fitter F with loosened fitter plate screws P on fitter plate N Twist light kit fitter F to lock...

Страница 14: ...ser is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Conn...

Страница 15: ...utton for fan MEDIUM speed 1 button for fan LOW speed 0 button to turn fan OFF button to turn light ON or OFF Tap button quickly to turn lights off or on Hold the button down to increase or decrease l...

Страница 16: ...osition will result in upward airflow that can help move stagnant hot air off the ceiling area At least twice each year lower canopy B to check downrod A assembly and tighten all screws on fan Clean m...

Страница 17: ...e 2 Unbalanced blades 3 Fan not securely mounted 4 Fan too close to vaulted ceiling 5 Set screw s on motor housing yoke is are not tightened properly 6 Set screw on hanging ball is not tightened prope...

Страница 18: ...anty does not cover changes in brass finish rusting pitting tarnishing corroding or peeling Brass finish fans maintain their beauty when protected from varying weather conditions Any glass provided wi...