17
WARNING:
Before beginning work, shut off the power supply to avoid electrical shock.
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Fan does not
move.
1. Reverse switch not engaged.
2. Power is off or fuse is blown.
3. Faulty wire connection.
4. Wires in light kit fitter not wired
correctly.
1. Push switch firmly either up or
down.
2. Turn power on or check fuse.
3. Turn power off. Loosen canopy
and check all connections.
4. Check that molex connections in
light kit fitter are connected
properly according to instructions
on page 12.
Noisy operation.
1. Blades are loose.
2. Cracked blade.
3. Fan is new.
1. Tighten all motor screws/washers.
2. Replace blade.
3. Allow fan a “break in” period of a
few days, especially when running
the fan at Medium and High
speeds.
Excessive
wobbling.
1. Blades are loose.
2. Unbalanced blades.
3. Fan not securely mounted.
4. Fan too close to vaulted ceiling.
5. Set screw(s) on motor housing yoke
is (are) not tightened properly.
6. Set screw on hanging ball is not
tightened properly.
1. Tighten all motor screws/washers.
2. Switch one blade with a blade
from the opposite side.
3. Turn power off. Carefully loosen
canopy and verify that mounting
bracket is secure.
4. Use a longer downrod or move fan
to another location.
5. Tighten yoke set screw(s)
securely.
6. Carefully loosen and lower canopy
and verify that set screw on
hanging ball is tightened securely.
TROUBLESHOOTING
Fan operates but
lights fail (if
applicable).
1. Wires in canopy not wired properly.
2. Wall switch to fan is off.
3. Wires from light kit fitter not wired
correctly.
1. Check wires in canopy and, if
necessary, re-wire according to
instructions on pages 9 and 10.
2. Make sure wall switch to fan is on.
3. Check wires on light kit fitter and,
if necessary, re-wire according to
instructions on page 12.