Harbor Breeze C-TMH44CH5D1R Скачать руководство пользователя страница 3

3

SAFETY INFORMATION

When mounting fan to a ceiling outlet box, use a METAL octagonal outlet box; do NOT use a 
plastic outlet box. Secure the outlet box directly to the building structure. The outlet box and its 
support must be able to support the moving weight of the fan (at least 35 lbs.). 

  
 To avoid personal injury, the use of gloves may be necessary while handling fan parts with
 sharp edges.

  
To reduce the risk of fire, electrical shock or personal injury, wire connectors provided with this fan 
are designed to accept only one 12-gauge house wire and two lead wires from the fan. If your 
house wire is larger than 12-gauge or there is more than one house wire to connect to the  
corresponding fan lead wires, consult an electrician for the proper size wire connectors to use.

  

To reduce the risk of fire or electrical shock, do not use the fan with any solid-state speed control 
device or control fan speed with a full range dimmer switch.

  

To reduce the risk of fire, electrical shock or personal injury, do not bend the blade arms when 
installing them, balancing the blades or cleaning the fan. Do not insert objects between the rotating 
fan blades.

  

To reduce the risk of personal injury, use ONLY parts provided with this fan. The use of parts 
OTHER than those provided with this fan will void the warranty.

  

This fan MUST be installed with the safety cable provided with the fan. Failure to use the
safety cable provided may result in personal injury, damage to the fan or damage to other property.

  

Before installation, be sure to shut off electricity at main switch or circuit breaker in order to avoid 
electrical shock.

  

  

NOTE: 

This equipment has been tested and found to comply with the limits for a Class B digital 

  device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 

protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of 
the following measures:
        *      Reorient or relocate the receiving antenna.
        *      Increase the separation between the equipment and receiver.
        *      Connect the equipment into an outlet on a circuit different from that to which the 
              receiver is connected.

  
Consult the dealer or an experienced radio/TV technician for help.

WARNING

  

CAUTION

Be sure outlet box is properly grounded and that a ground wire (green or bare) is present.

  
Before beginning installation, carefully check all screws, bolts and nuts on fan motor assembly to 
ensure they are secure.

NOTE:

 

Dimmable to 10% with select dimmers.

Содержание C-TMH44CH5D1R

Страница 1: ...eserved MODEL C TMH44CH5D1R Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Fr...

Страница 2: ...l codes ordinances the Canadian Electrical Code and ANSI NFPA 70 1999 Hire a qualified electrician or consult a do it yourself wiring handbook if you are unfamiliar with installing electrical wiring M...

Страница 3: ...an Failure to use the safety cable provided may result in personal injury damage to the fan or damage to other property Before installation be sure to shut off electricity at main switch or circuit br...

Страница 4: ...to Motor Housing C PACKAGE CONTENTS 4 DESCRIPTION PART QUANTITY DESCRIPTION PART QUANTITY IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety H F B I A...

Страница 5: ...rewdriver Pliers Safety Glasses Stepladder and Wire Strippers Helpful Tools not included AC Tester Light Tape Measure Do It Yourself Wiring Handbook and Wire Cutters HARDWARE CONTENTS shown actual siz...

Страница 6: ...remove that mounting plate screw K Then remove mounting plate screw K on outer edge of mounting plate A directly opposite the mounting plate screw K that was just removed Partially loosen the other t...

Страница 7: ...g ring B with indentations at top of motor housing C Then push housing ring B down about 1 2 in past top edge of motor housing C 6 A Non slotted Hole J hook C 1 Find a secure attachment point wood cei...

Страница 8: ...trol fan speed WIRING 1 Make the necessary wiring connections for remote control operation as detailed below and in the figure For each wire connection use one of the wire connectors CC making sure to...

Страница 9: ...ws K in mounting plate A Twist motor housing C to lock Re insert the two mounting plate screws K previously removed Step 3 page 6 and then tighten all four mounting plate screws K to secure motor hous...

Страница 10: ...otor plate screws I allowing female plug from motor housing C to come through hole in middle of fitter plate D Twist fitter plate D to lock Re insert motor plate screw I that was removed and tighten a...

Страница 11: ...hock personal injury or death Align slotted holes in LED light kit E with loosened screws in fitter plate D Twist LED light kit E to lock Re insert fitter plate screw J previously removed step 5 page...

Страница 12: ...on fitter plate D as this could damage the wires which could cause the risk of fire electrical shock personal injury or death DANGER Make sure wires do not get pinched in between LED light kit E and p...

Страница 13: ...ling center by calling 1 800 8 BATTERY or 1 877 2 RECYCLE or visit www epa gov epawaste index htm or www earth911 org for more information WARNING Choking Hazard Small parts Keep battery away from chi...

Страница 14: ...ht BRIGHTNESS and to turn light OFF The light function is controlled by pressing the button Hold button down to increase or decrease light Tap button quickly to turn light off or on If you press the b...

Страница 15: ...power off Carefully loosen motor housing and verify that mounting plate is secure according to instructions on page 6 Excessive wobbling 1 Blades are loose 2 Unbalanced blades 3 Fan not securely mount...

Страница 16: ...performed by an unauthorized person will render the warranty invalid Due to varying climatic conditions this warranty does not cover changes in brass finish rusting pitting tarnishing corroding or pe...

Отзывы: