Harbor Breeze 80202 Скачать руководство пользователя страница 3

42940-01  02/06/2008

E

F

G

H

I

L

M

N

95047-03-000

75864-02-000

03242-07-133

95261-02-000

74508-03-133

96397-01-214

75184-01-133

86812-01-000

O

75733-01-214

x4

*

*

*

NOTE:

Strain relief cable 

connector must be 

installed. Not Included.

A

B

C

Extra Screws

x2

D

3/8 in. Cable Connector

x2

J

77522-01

Strain Relief Bracket

K

65219

Strain Relief Bracket Screw

Motor/Blower

Screws

Light Fixture

Thumbscrews

Glass Dome

Finial

Housing

Wiring Cover

Wiring Cover Screw

1

Turn off the power source.

Tools Needed. (Not supplied.)

Estimated assembly time: 30 to 60 minutes

 

Before Installation

Check all the parts. 

If damaged, call 

1-866-405-3814 

for replacements.

Included.

2

E

I

Loosen screws.

NOTE: Remove all packing materials before installation.

42940-01_2.6.08_Arial.indd   3

2/6/08   2:30:32 PM

Содержание 80202

Страница 1: ...8 I n s t a l l a t i o n G u i d e 80202 Bath Ventilator with Light READ and SAVE THESE INSTRUCTIONS ENGLISH See page 2 Espa ol Vea la p gina 29 francais Voir la page 15 42940 01_2 6 08_Arial indd 1...

Страница 2: ...time C A U T I O N W arning 1 Use this unit only in a manner intended by the manufacturer If you have questions contact the manufacturer 2 Before servicing or cleaning the unit switch power off at se...

Страница 3: ...2 01 Strain Relief Bracket K 65219 Strain Relief Bracket Screw Motor Blower Screws Light Fixture Thumbscrews Glass Dome Finial Housing Wiring Cover Wiring Cover Screw 1 Turn off the power source Tools...

Страница 4: ...the housing H E 3 Remove the pre loaded screw tip covers Remove the wiring cover screw 6 Back out the pre loaded screw tips until flush with the side of the housing Remove the wiring cover Remove pac...

Страница 5: ...osition the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock New Construction 10 B C Choose Installation Option For New Construction go to step A1 page 5 For...

Страница 6: ...as shown A3 Route wires through the strain relief For supply connection use wires suitable for at least 90 C 194 F A6 A5 E F G Install the wiring cover plate Make sure all wiring connections are insi...

Страница 7: ...ecure the motor blower by tightening the 2 screws Turn on the power source Connect wiring harness DO NOT ALLOW THE MOTOR BLOWER TO HANG FROM THE WIRING HARNESS 0 0 0 0 0 0 0 0 A7 0 0 0 0 0 0 0 0 H A8...

Страница 8: ...the opening is large enough to accommodate the new motor blower housing 7 1 4 in x 7 3 4 in Move the housing into position above the ceiling Attach existing ducting to duct connector Tape joints If du...

Страница 9: ...arness DO NOT ALLOW THE MOTOR BLOWER TO HANG FROM THE WIRING HARNESS Secure the motor blower by tightening the 2 screws A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White Wh...

Страница 10: ...ge 10 to attach grille B11 Turn on the power source L O C2 N M C1 Attaching the Grille Remove the thumbscrews Remove glass dome Test the motor blower If the motor blower does not run check the plug co...

Страница 11: ...stall the strain relief bracket screw L C3 Connect wiring harness DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS C7 L L C8 M Align posts 1 2 and 3 stamped into motor blower housing with post...

Страница 12: ...42940 01 02 06 2008 12 C9 C10 N O C11 Align glass dome and push up Install 2 Max 60 Watt A15 bulbs Not Included Screw glass dome into position 42940 01_2 6 08_Arial indd 12 2 6 08 2 30 57 PM...

Страница 13: ...ke sure it matches the wiring diagram Problem Light does not come on Solution Replace the light bulb with a new bulb Turn power on replace fuse or reset breaker Check all plug connections to be sure t...

Страница 14: ...Y IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO ANY HARBOR BREEZE BATH EXHAUST FAN MOTOR BLOWER OR OTHER FAN P...