  Warranty

Harbor Breeze

Bath Exhaust Fan

LIMITED WARRANTY

The manufacturer makes the following limited warranty to the original user or consumer purchaser of this Harbor Breeze bath 

exhaust fan:

If any part of your Harbor Breeze bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year 

after the date of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part 

free of charge. After this one-year period, you will be responsible for all parts and labor costs for repairs on the bath exhaust fan 

except for motor/blower repairs as provided below.

If your Harbor Breeze bath exhaust fan motor/blower fails at any time within five years after the date of sale to you due to a 

defect in material or workmanship, labor and materials to repair the defect will be provided free of charge. If no replacement part 

can be provided, we will, at our option, either refund the actual purchase price of your bath exhaust fan or provide a replacement 

free of charge. After this five-year period, you will be responsible for all parts and labor costs for repairs on all parts of the bath 

exhaust fan.  

IF THE ORIGINAL USER OR CONSUMER PURCHASER CEASES TO OWN THE FAN, THIS WARRANTY AND ANY IM-

PLIED WARRANTY WHICH THEN REMAINS IN EFFECT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE VOIDED. NO WARRANTY, EXPRESS OR IMPLIED, 

INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS MADE IN RESPECT 

OF GLASS FIXTURES OR LIGHT BULBS OR THE FINISH ON ANY METAL PORTION OF THE BATH EXHAUST FAN.

THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, 

INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 

PURPOSE, IN RESPECT TO ANY HARBOR BREEZE BATH EXHAUST FAN MOTOR/BLOWER OR OTHER FAN PART, IS 

EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH MOTOR/BLOW-

ERS OR OTHER PARTS.

This warranty is voided if your Harbor Breeze bath exhaust fan is not purchased and installed in the U.S.A. This warranty 

excludes and does not cover defects, malfunctions or failures of any Harbor Breeze bath exhaust fan which were caused by 

repairs by persons not authorized by us, use of parts or accessories not authorized by us, mishandling, improper installation, 

modifications or damage to the Harbor Breeze bath exhaust fan while in your possession, or unreasonable use, including failure 

to provide reasonable and necessary maintenance.

To obtain servicing, contact the Harbor Breeze Service Department at 1-866-405-814. Please contact us before shipping your 

bath exhaust fan to us. If we authorize you to ship it to us, you will be responsible for all insurance and freight or other transpor-

tation charges to our factory or service center. We will return your Harbor Breeze bath exhaust fan freight prepaid. Your Harbor 

Breeze bath exhaust fan should be properly packed to avoid damage in transit since we will not be responsible for any such 

damage. Proof of purchase is required when requesting warranty service. The purchaser must present the sales receipt or other 

document that establishes proof of purchase.

IN NO EVENT SHALL THE MANUFACTURER BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES.

SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR 

LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT 

APPLY TO YOU.

THE WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM 

STATE TO STATE. 

42940-01_2.6.08_Arial.indd   14

2/6/08   2:30:58 PM

Содержание 80202

Страница 1: ...8 I n s t a l l a t i o n G u i d e 80202 Bath Ventilator with Light READ and SAVE THESE INSTRUCTIONS ENGLISH See page 2 Espa ol Vea la p gina 29 francais Voir la page 15 42940 01_2 6 08_Arial indd 1...

Страница 2: ...time C A U T I O N W arning 1 Use this unit only in a manner intended by the manufacturer If you have questions contact the manufacturer 2 Before servicing or cleaning the unit switch power off at se...

Страница 3: ...2 01 Strain Relief Bracket K 65219 Strain Relief Bracket Screw Motor Blower Screws Light Fixture Thumbscrews Glass Dome Finial Housing Wiring Cover Wiring Cover Screw 1 Turn off the power source Tools...

Страница 4: ...the housing H E 3 Remove the pre loaded screw tip covers Remove the wiring cover screw 6 Back out the pre loaded screw tips until flush with the side of the housing Remove the wiring cover Remove pac...

Страница 5: ...osition the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock New Construction 10 B C Choose Installation Option For New Construction go to step A1 page 5 For...

Страница 6: ...as shown A3 Route wires through the strain relief For supply connection use wires suitable for at least 90 C 194 F A6 A5 E F G Install the wiring cover plate Make sure all wiring connections are insi...

Страница 7: ...ecure the motor blower by tightening the 2 screws Turn on the power source Connect wiring harness DO NOT ALLOW THE MOTOR BLOWER TO HANG FROM THE WIRING HARNESS 0 0 0 0 0 0 0 0 A7 0 0 0 0 0 0 0 0 H A8...

Страница 8: ...the opening is large enough to accommodate the new motor blower housing 7 1 4 in x 7 3 4 in Move the housing into position above the ceiling Attach existing ducting to duct connector Tape joints If du...

Страница 9: ...arness DO NOT ALLOW THE MOTOR BLOWER TO HANG FROM THE WIRING HARNESS Secure the motor blower by tightening the 2 screws A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White Wh...

Страница 10: ...ge 10 to attach grille B11 Turn on the power source L O C2 N M C1 Attaching the Grille Remove the thumbscrews Remove glass dome Test the motor blower If the motor blower does not run check the plug co...

Страница 11: ...stall the strain relief bracket screw L C3 Connect wiring harness DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS C7 L L C8 M Align posts 1 2 and 3 stamped into motor blower housing with post...

Страница 12: ...42940 01 02 06 2008 12 C9 C10 N O C11 Align glass dome and push up Install 2 Max 60 Watt A15 bulbs Not Included Screw glass dome into position 42940 01_2 6 08_Arial indd 12 2 6 08 2 30 57 PM...

Страница 13: ...ke sure it matches the wiring diagram Problem Light does not come on Solution Replace the light bulb with a new bulb Turn power on replace fuse or reset breaker Check all plug connections to be sure t...

Страница 14: ...Y IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO ANY HARBOR BREEZE BATH EXHAUST FAN MOTOR BLOWER OR OTHER FAN P...

Отзывы: