CLOSEMOUNT INSTRUCTIONS

1.  Remove and discard the canopy cover (F) from the 

bottom of the canopy (E).

Note:

 The downrod (A), yoke cover (J) and canopy 

cover (F) are not used in this type of installation.

1

2.  Remove three Phillips-head closemount screws (O) 

from the top of the motor assembly (G). Align the 

canopy (E) with the holes in the top of the motor 

assembly (G), then re-install the Phillips-head 

closemount screws (O) to secure the canopy (E) to 

the top of the motor assembly (G).

3.  Raise the fan and place the canopy (E) on the 

hook on the mounting bracket (D). Then, place the 

receiver from remote pack (N) inside the mounting 

bracket (D) with flat side facing the ceiling. 

 

E

E

G

E

D

F

3

Hook

Receiver

2

O

Содержание 0888516

Страница 1: ...Purchase Date _________________________ ITEM 1607162 43105016 0888516 43105022 BELLEISLE BAY CEILING FAN MODEL 41169 41172 Fran ais p 23 RR20002 Questions problems missing parts Before returning to yo...

Страница 2: ...ration 6 Initial Installation 7 Standard or Angle Mounting Instructions 9 Closemount Instructions 12 Secondary Hanging System 13 Wiring 14 Final Installation 15 Operating Instructions 18 Care and Main...

Страница 3: ...Canopy E 1 G Motor Assembly 1 H Fitter Plate preassembled to the Motor Assembly G 1 I Light Kit 1 J Yoke Cover 1 K Blade 3 L Bulb 2 M Glass Bowl 1 N Remote Pack 1 O Phillips Head Closemount Screw prea...

Страница 4: ...E CONTENTS Wire Connector Qty 6 1 extra Blade Screw Qty 9 1 extra Blade Washer Qty 9 1 extra Secondary Support Screw Qty 1 Support Washer Qty 1 Secondary Spring Washer Qty 1 shown actual size AA BB CC...

Страница 5: ...dimmer switch to control the fan speed WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked ACCEPTABLE FOR FAN SUPPORT and use the mounting screws...

Страница 6: ...ng two conditions 1 This device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device if applicable PREPARAT...

Страница 7: ...ing is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensure proper blade clearance Important If using the angle mount check to ensure the ceiling angle is not s...

Страница 8: ...opy E Set aside for later use Detach mounting bracket D from canopy E 5 Attach mounting bracket D to outlet box not included using screws and washers provided with the outlet box CAUTION It is very im...

Страница 9: ...a longer downrod if required through the canopy E and yoke cover J Feed the wires and braided cable from the fan through the downrod A 3 Slide the downrod A into the yoke of the motor assembly G align...

Страница 10: ...rip 1 2 in of insulation from the end of the white wire Twist the stripped ends of each strand of wire within the insulation with pliers not included Repeat the step for black and blue wires Note If y...

Страница 11: ...ANDARD OR ANGLE MOUNTING INSTRUCTIONS 7 Insert the receiver from remote pack N into the mounting bracket D with the flat side facing the ceiling Proceed to Secondary Hanging System on page 13 D 7 Rece...

Страница 12: ...ws O from the top of the motor assembly G Align the canopy E with the holes in the top of the motor assembly G then re install the Phillips head closemount screws O to secure the canopy E to the top o...

Страница 13: ...ary support screw JJ Note The ceiling support brace may not be accessible from below If not it must be accessed from above Important The braided cable must make a complete circle around the support br...

Страница 14: ...from the receiver from remote pack N to the Black fan wire Connect the Red wire with red label from the receiver from remote pack N to the Black hot power supply wire Connect the White wire with red l...

Страница 15: ...eyholes of the canopy E onto the mounting bracket screws P and rotate the canopy E clockwise 2 Secure the canopy E with the mounting bracket screws P previously removed Step 4 page 8 Tighten all mount...

Страница 16: ...to the fitter plate H and loosen the other two but do not remove Connect the single pin connector from the fitter plate H to the single pin connector from the light kit I blue to blue and white to whi...

Страница 17: ...tion until it is secure 7 If desired the clip in remote pack N can be installed to a wall using the provided clip screws The remote from remote pack N can hang from the clip for easy access 8 Turn on...

Страница 18: ...off Press and hold this button to dim or brighten the lights if applicable 3 The reverse switch is located on the top of the motor assembly G Using a ceiling fan will allow you to raise your thermosta...

Страница 19: ...RECTIVE ACTION The fan does not move 1 The power is off or the fuse is blown 2 There is a faulty wire connection 3 The plugs are not connected properly 4 The reverse switch is not completely engaged 1...

Страница 20: ...the yoke until secure The fan operates correctly but the lights are not working 1 The bulbs are not installed correctly 2 The light kit wire plugs are not connected properly 3 There is a faulty wire...

Страница 21: ...varying climate conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life...

Страница 22: ...Downrod 4L000010220 4L000010240 D Mounting Bracket 4L000006280 4L000004480 E Canopy 4L000004350 4L000004470 F Canopy Cover 4L000002900 4L000004500 I Light Kit 4L000012710 4L000012720 J Yoke Cover 4L00...

Отзывы: