background image

6

7

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

1.   Determine mounting method to use. 

A - Downrod Mount 

B - Angle Mount 

Important:

 If using the angle mount, check to 

make sure the ceiling angle is not steeper than 20˚ 

4.  Remove the preassembled pin and clip from 

downrod (E). Insert downrod (E) through canopy 

(B) and yoke cover (D). Thread wires from fan 

motor assembly (F) through downrod (E).

2.  Remove the mounting bracket (A) from the canopy 

(B) by loosening the four screws on the top of the 

canopy (B). Remove the two non-slotted screws and 

save.

3.  Install mounting bracket (A) to outlet box (not 

included) by sliding mounting bracket (A) 

over the two outlet box screws (not included). 

Securely tighten two outlet box screws.

  IMPORTANT:

 If angle mounting, make sure 

open end of mounting bracket (A) is installed 

facing the ceiling.

5.  Loosen the two set screws from the yoke. Slip 

downrod (E) into the yoke, then re-insert pin 

and clip. Tighten set screws to secure.

E

B

D

Clip

Pin

4

Loosen but

do not remove

Remove

and save

A

B

2

1

Pin

Yoke

Clip

Set screw

E

F

5

3

6

 

Outlet box

A

6.  Carefully lift the motor assembly (F) up to the 

mounting bracket (A). Install hanger ball on the 

top of downrod (E) into opening of mounting 

bracket (A). Rotate fan until slot on hanger ball 

engages  the  tab  on  the  mounting  bracket  (A).                               

 DANGER:

 Be careful when aligning the tab to 

the slot! If not fully engaged, there is a possibility 

of fan falling, which may result in serious injury 

or death.

Lowes.com/harborbreeze

Lowes.com/harborbreeze

Page 6

Page 7

Tab

Slot

A

E

Содержание 00878

Страница 1: ...emark of LF LLC All Rights Reserved Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p...

Страница 2: ...he risk of fire electric shock or personal injury mount to an outlet box marked ACCEPTABLE FOR FAN SUPPORT OF 35 1 lbs OR LESS and use the mounting screws provided with the outlet box Most outlet boxe...

Страница 3: ...not included Phillips screwdriver step ladder electrical tape pliers wire cutters wire strippers Helpful Tools not included Electrical Circuit tester PACKAGE CONTENTS PART DESCRIPTION QUANTITY A Mount...

Страница 4: ...ncluded Securely tighten two outlet box screws IMPORTANT If angle mounting make sure open end of mounting bracket A is installed facing the ceiling 5 Loosen the two set screws from the yoke Slip downr...

Страница 5: ...plate G clockwise until it locks Re install the previously removed screw then tighten all screws securely 7 Insert receiver from the remote pack L into mounting bracket A with the flat side toward the...

Страница 6: ...turn the light fitter assembly I clockwise until it locks Re install the previously removed screw then tighten all screws securely Screw 2 I ASSEMBLY INSTRUCTIONS 16 Install bulbs K to sockets on ligh...

Страница 7: ...s and hold the Learn button on the remote control for 1 second Once the receiver has detected the set frequency the light of the fan will blink twice Replace the battery cover To confirm the remote co...

Страница 8: ...y of the purchaser There is no further expressed warranty The manufacturer disclaims any and all implied warranties The duration of any implied warranty which can not be disclaimed is limited to the l...

Страница 9: ...LLC Todos los derechos reservados Preguntas problemas piezas faltantes Antes de volver a la tienda llame a nuestro Departamento de Servicio al Cliente al 1 800 643 0067 de lunes a jueves de 8 a m a 6...

Страница 10: ...EL CTRICAS O LESIONES PERSONALES para reducir el riesgo de incendio descargas el ctricas o lesiones personales monte el ventilador en una caja de salida marcada como ACCEPTABLE FOR FAN SUPPORT OF 35 1...

Страница 11: ...lador Phillips escalera de tijera cinta aislante pinzas pinzas cortacables pinzas pelacables Herramientas tiles no se incluyen probador de circuito el ctrico CONTENIDO DEL PAQUETE PIEZA DESCRIPCI N CA...

Страница 12: ...s de la caja de salida IMPORTANTE Si realiza el montaje en ngulo aseg rese de que el extremo abierto del soporte de montaje A est instalado en direcci n hacia el techo 5 Afloje los dos tornillos de fi...

Страница 13: ...el tornillo que retir con anterioridad y luego apriete bien todos los tornillos 7 Inserte el receptor del paquete remoto L en el soporte de montaje A con el lado plano orientado hacia el techo Conect...

Страница 14: ...uee Vuelva a instalar el tornillo que retir con anterioridad y luego apriete bien todos los tornillos Tornillo 2 I INSTRUCCIONES DE ENSAMBLAJE 16 Instale las bombillas K en los portal mparas del ensam...

Страница 15: ...de los 30 segundos luego de encender la alimentaci n el ctrica del ventilador mantenga presionado el bot n Learn Aprender del control remoto durante 1 segundo Una vez que el receptor detecta la frecue...

Страница 16: ...cita El fabricante rechaza cualquiera y todas las garant as impl citas La duraci n de cualquier garant a impl cita que no pueda rechazarse se limita al per odo limitado de por vida especificado en nue...

Отзывы: