120
Machine Test Machine movement
4-4-2
Below operation will be moved solely. In some operations, actuator of motor will be moved, Keep hands and face away during
movement for your own safety.
#1 Needle Adjust : Input of Needle bar detect Potentiometer
(Not used in HCH)
#2 Cutter Adjust : Action test of moving knife Open-Close
Use this function to adjust stop position of Moving knife.
#3 Catcher Adjust : Action test of Thread catch hook
This test is used to adjust stop position of Thread catch
hook.
#4 Keeper Test : Action test of Keeper solenoid ON-OFF
This test is used to check action of Keeper.
#5 Jump Solenoid Test : Movement test of jump device
ON-OFF
This test is used to check movement of Jump device.
#6 Catcher Test : Movement test of thread catch hook
IN-OUT
Use this test to check movement of Thread catch hook.
#7 Cutter Test : Action test of moving knife Open-Close
Use this function to check opening-closing action of
Moving knife.
#8 Clip Solenoid : Action test of clip type thread holder
(Not used in HCH)
This test is used to check movement of clip type thread
holder.
#9 Pointer Test : Action test of laser pointer
This test is used to check action of Laser pointer.
#10 Fan Drive Test : Action test of cooling fan ON-OFF
(Not used in HCH)
Use this function to check movement of cooling fan.
#11 Encoder Check : Input test of L point / C point timing
(Not used in HCH)
With turning main shaft, you can use this function to
check if L point signal, C point signal, and timing signal
are correct or not.
#12 Position Data Entry : Position Data Entry Confirm frame
moving sensor
This test is used to check action of Frame moving
sensor.
From Main program Ver.*1.34~, the Pulse motor will be
un-locked when you activate the test, then you can
move the embroidery frame to your desire position.
#13 Position Data Entry : Confirm registration of frame
position data (Not used in HCH)
You can use this function to check if Frame position data
are entered correctly.
#14 Shaft Drive Test : Main shaft control test
You can turn main shaft with pushing “Start” or “Jump”
key of Needle bar section.
This function can be used for test run after maintenance
work.
#15 Sequin test (Not used in HCH)
This test is used to check or adjust of Sequin device.
#16 Rotary Hook Adjust
(
Main program Ver.*1.37~
)
This function can be used for [Adjustment of
needle height] or [Adjustment of rotary hook
timing].
40, 220 degrees
160, 340 degrees 100, 280 degrees
[01]–[15]: Needle change
[L point]: Main shaft will turn and set Needle bar
position for [Adjustment of needle height] (L+5
degree).
[Rotary hook]: Rotary hook will turn and stop every
120 degrees to access 3 fixing screws easier.
[Ndl +1],[Ndl -1]: Needle bar moves to the left or
right, then sets Needle bar position for
[Adjustment of needle height] (L+5 degree).
#17 Needle Posi. Adjust
(Not used in HCH)
Содержание HCH-701-30
Страница 1: ...Maintenance Manual for Embroidery Machine HCH 701 30 Version 2 4 HappyJapan Inc ...
Страница 132: ...128 Electrical connection diagram 5 ...
Страница 133: ...129 Electrical connection diagrams 5 ...
Страница 134: ...130 List of electrical connection diagrams 5 ...
Страница 137: ...130c HCD81222 LCD CE MX 基板組 ...
Страница 138: ...130d HCD8116 TP switch board ass y 3 82 7 32 7 387487 2487 ...
Страница 170: ...156 Use TAJIMA made tubular frame 7 4 2 ...
Страница 171: ...2019 12 HappyJapan Inc 9 5 TAITO 2 CHOME TAITO KU TOKYO JAPAN TEL 81 3 3834 0711 FAX 81 3 3835 8917 ...