Wagenbouw HAPERT
30
Figure 13
Hydraulic pump oil level:
Check the hydraulic oil level and, if necessary, top it up.
For an electric pump: when the cylinders are in the highest position, the level must
be up to 10 cm below the edge of the cover.
For a hand pump: when the cargo bed is down, the level must be up to 1 cm below
the edge of the cover.
Battery, charge it if necessary:
A disconnected battery should be stored in a dry, frost-free location in your
warehouse (this is vital to reduce self-discharge to a minimum).
After a few months, the battery will have discharged itself and its condition should,
therefore, be checked. At 12.2 V (this is 80% of its capacity), the battery needs to be
recharged with a charger that has a capacity equal to at least 10% of the battery’s
capacity (e.g. a 90 Ah battery must be recharged with a charger of at least 8 A and
no more than10 A in order to obtain the best results).
This also applies to batteries that are installed in products in your showroom, so
please check their condition regularly and, if needed, recharge to 12.7 V (100%
battery charge).
If you neglect to do this, battery sulphation will irrevocably occur (lead sulphate that
attaches itself to the plates) and recharging will no longer be possible.
Sulphated batteries are not covered by warranty.
Attention!
You should
never
charge the battery with a quick charger.
Always use a trickle charger.
Depending on the type of trailer, it may have a plug socket for a battery charger.
Содержание COBALT HB
Страница 4: ...Wagenbouw HAPERT 4...