There  is  a  danger  of  occurring  electric  shock  in  the  input/output  terminals  so  please  never  let  your  body  or 
conductive substance is touched.

•This product does not contain an electric switch or fuse, so the user needs to install a separate electric switch 
   or fuse externally. (Fuse rating : 250 V 0.5 A)
•To prevent defection or malfunction of this product, apply a proper power voltage in accordance with the rating.
•To prevent electric shock or malfunction of product, do not supply the power until the wiring is completed.
•Since this product is not designed with explosion-protective structure, do not use it any place with flammable or explosive gas.
•Do not decompose, modify, revise or repair this product. This may be a cause of malfunction, electric shock or fire.
•Reassemble this product while the power is OFF. Otherwise, it may be a cause of malfunction or electric shock.
•If you use the product with methods other than specified by the manufacturer, there may be  bodily injuries or property damages.
•There is a possibility of occurring electric shock so please use this product after installing it onto a panel while it is operating.

•The contents of this manual may be changed without prior notification.
•Do not use this product at any place with occurring corrosive (especially noxious gas or ammonia) or flammable gas.
•Do not use this product at any place with direct vibration or impact.
•Do not use this product at any place with liquid, oil, medical substances, dust, salt or iron contents.(Use at Pollution level 1 or 2)
•Do not polish this product with substances such as alcohol or benzene. (Use neutral detergent.)
•Do not use this product at any place with a large inductive difficulty or occurring static electricity or magnetic noise.
•Do not use this product at any place with possible thermal accumulation due to direct sunlight or heat radiation.
•Install this product at place under 2,000 m in altitude.
•When the product gets wet, the inspection is essential because there is danger of an electric leakage or fire.
•If there is excessive noise from the power supply, using insulating transformer and noise filter is 
   recommended. The noise filter must be attached to a panel which is already connected to a ground 
   and the wire between the filter output side and power supply terminal must be short as possible.
•If twisting the power cables closely together then it is effective against noise.
•Do not connect anything to the unused terminals.
•After checking the polarity of terminal, connect wires at the correct position.
•When this product is connected onto a panel, use a circuit breaker or switch approved with IEC60947-1 or IEC60947-3.
•Install a circuit breaker or switch at near place for convenient use.
•For the continuous and safe use of this product, the periodical maintenance is recommended.
•Some parts of this product have limited life span, and others are changed by their usage.
•The warranty period for this product including parts is one year if this product is properly used.

Danger

Warning

Caution

Connection diagram

Power supply voltage

100 - 240 V a.c, 50 - 60 Hz (dual usage), allowable voltage fluctuation : ±10 %

Power consumption

Approx. 6 VA

Display method

7 segments LED display

Measurement method

Cycle measuring method, Cos φ = LEAD 0.1 ~ 1 ~ LAG 0.1

Display cycle

0.5 ~ 2sec (Operation may not be accurate or display cycle may 
become slow when the load is less than 5% of rated current)

Display range

±0.10 - 1.00 

Measurement list

Power factor (Cos φ)

Input voltage

0 - 220 V a.c  50 - 60 Hz

Input current

5 A, 1 A (external current transformer secondary current)

Accuracy

2 % (display range)

Hold function

Hold and externally hold the max measurement value and min 
measurement value by detect them automatically.  

Control

Hold the displayed value

Other functions

•Comparative output •Max value / min value indication by the front key 
•Protect the set value from changing •Average the value and delay the display cycle

Output (Optional)

·Relay contact output(HI, GO, LO) ·Retransmission(4 - 20 ㎃)             

Insulation resistance

100 min ㏁(500 V d.c mega standard) between the external terminal and case

Dielectric strength

2000 V a.c for 1 min (between the external terminal and case)

Noise immunity

Square wave noise by the noise simulator pulse width 1 ㎲, ±1000 V

Vibration 

resistance

Malfunction 10 -55 Hz peack amplitude 0.5mm X/Y/Z each direction for 1 hour
Resistance 10 -55 Hz peack amplitude 0.5mm X/Y/Z each direction for 2 hours

Shock resistance

Malfunction 100 ㎨  X·Y·Z each direction for 3 times
Resistance 300 ㎨  X·Y·Z each direction for 3 times

Ambient temperature

-10 ~ 55 ℃ (icing or dew condensation not allowed)

Ambient humidity

35 ~ 85 % RH (without dew condensation)

Storage temperature

-20 ~ 65 ℃ (icing or dew condensation not allowed)

Relay Life span

Phisical : 20,000,000 ㎰ Min ,  Electrical : 100,000 ㎰ Min
Capacity of Contact : 250 V a.c 5 A, 30 V d.c 5 A ,  Structure of Contact : N.O (1a)

Weight

Approx. 300 g

Specification

Suffix code

Model

Code

Information

PF3-

Digital power factor meter (96X48X102.6 ㎜)

Displayable 
digit

1

Single phase 0 - 220 V a.c

Measuring input 
signal

01

XXX : 5 A (Use the all-purpose current transformer)

02

XXX : 1 A (Use the all-purpose current transformer)

Output (Optional)

N

Display only

0

Relay output (HI, GO, LO) + current output (4-20 ㎃)

1

Relay output (HI, GO, LO)

※ “-” is displayed when it is leading power factor

(Heater, motor, general load)

(Heater, motor, general load)

● PF3-1-0 (Relay output, 4 - 20 ㎃ current output)

● PF3-1-1 (Relay output)

Caution) Relay output is not related to leading current and lagging current.

Dimension and panel cutout

102.6

102.6

102.6

Safety information

Before using the product, please read the safety information thoroughly and use it properly.Alerts 
declared in the manual are classified to Danger, Warning and Caution by their criticality

DANGER

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury

WARNING

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury

CAUTION

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury

   Digital power factor meter

  

PF3

 

     
      

Thank you for purchasing HANYOUNG product.

      Please check whether the product is the exactly same as you ordered. 
      Before using the product, please read this instruction manual carefully.
      Please keep this manual where you can view at any time

 INSTRUCTION MANUAL

1381-3, Juan-Dong, Nam-Gu Incheon, Korea.  
TEL:(82-32)876-4697 FAX:(82-32)876-4696 
http://www.hynux.net

HANYOUNGNUX CO.,LTD

HEAD OFFICE

INDONESIA

FACTORY

JL.CEMPAKA BLOK F 16 NO.02 DELTA SILICON II 
INDUSTRIAL PARK
LIPPO CIKARANG CICAU, CIKARANG PUSAT BEKASI 
17550 INDONESIA
TEL : 62-21-8911-8120~4  FAX : 62-21-8911-8126 

PT. HANYOUNG ELECTRONIC INDONESIA

[Unit:mm]

Содержание PF3

Страница 1: ... 스위치나 차단기는 운전자가 조작이 용이하도록 가까운 거리에 설치하십시오 본 기기를 계속적으로 안전하게 사용하기 위하여 정기적인 보수를 권장합니다 본 기기의 탑재부품에는 수명이 있는 것과 경년 변화 하는 것이 있습니다 부속품을 포함한 본기기의 보증기간은 정상적으로 사용한 경우에 1년입니다 위 험 경 고 주 의 접속도 전 원 전 압 100 240 V a c 50 60 공용 허용 전압변동 범위 10 소 비 전 력 약6 VA 표 시 방 식 7 세그먼트 LED 표시 측 정 방 식 주기측정방식 COS Ø LEAD 0 1 1 LAG 0 1 표 시 주 기 0 5 2초 정격전류의 5 이하의 부하에서는 동작이 부정확하거나 표시주기가 느려질 수 있습니다 표 시 0 10 1 00 측 정 항 목 역률 COS φ 입 력 전 압 0...

Страница 2: ...ey 로 설정 자릿수 이동 SHIFT KEY Key 로 설정 Key 로 설정 자릿수 이동 SHIFT KEY Key 로 설정 자릿수 이동 SHIFT KEY 9 999 비교출력 상한설정 최대값 1 999 비교출력 상한설정 최저값 9 999 비교출력 상한설정 최대값 1 999 비교출력 상한설정 최저값 LL ot 99 최대값 00 최저값 HH ot LH ot HL ot IL ot Key 설정완료 Key 설정완료 Key 설정완료 Key 설정완료 Key 설정완료 Key 설정완료 입력최대값 표시 입력최저값 표시 비교출력 상한값 설정 비교출력 하한값 설정 비교출력 모드 설정 초기설정값 01 RUN MODE에서 KEY를 짧게 2초이상 누르면 LOCK 설정모드로 진입합니다 Key Key 설정완료 Key 설정시작 Key 설정시...

Страница 3: ...1 LAG 0 1 Display cycle 0 5 2sec Operation may not be accurate or display cycle may become slow when the load is less than 5 of rated current Display range 0 10 1 00 Measurement list Power factor Cos φ Input voltage 0 220 V a c 50 60 Hz Input current 5 A 1 A external current transformer secondary current Accuracy 2 display range Hold function Hold and externally hold the max measurement value and ...

Страница 4: ...the mix comparative output value LL ot 99 max value 00 min value HH ot LH ot HL ot IL ot Display of the max input value Display of the min input value set up the max comparative output value set up the min comparative output value Set the comparative output mode Default value 01 Key set up completed Key set up completed Key set up completed Key set up completed Key set up completed Key set up comp...

Отзывы: