Pr
ogr
ammable T
emper
atur
e & Humidity Contr
oller
28
Digit
al Mold Contr
oller
◈
Operation control screen
Name
Display screen
Description
Display
Initial value
Ph
Ph, Ih,
Dh, Th
Heating Proportional Band
0.0 ~ 300.0 ℃
20.0 ℃
Ih
Heating Integral Time
0 ~3600 s
240 s
Dh
Heating Derivative Time
60 s
Th
Heating Control Cycle
0 ~ 100 s
2 s
Pc
Pc, Ic,
Dc, Tc
Cooling Proportional Band
0.0 ~ 300.0 ℃
20.0 ℃
Ic
Cooling Integral Time
0 ~ 3600 s
240 s
Dc
Cooling Derivative Time
60 s
Tc
Cooling Control Cycle
0 ~ 100 s
2 s
Auto/Manual
MODE
Output mode
AUTO / MAN
AUTO
◈
Output operation screen
Name
Display screen
Description
Display
Initial value
Cooling output
COOL OUT
Select whether to use
cooling output
USE / NOT USE
NOT USE
Heating output
HEAT OUT
Select power source for
heating output
SINGLE PHASE/
THREE PHASE
SINGLE
PHASE
TEMP.HI ALM
TEMP.HI
High temperature limit
alert
0.0 ~ 300.0 ℃
300 ℃
TEMP.LO ALM
TEMP.LO
Low temperature limit
alert
0.0 ℃
PRES.HI ALM
PRES.HI
High pressure limit alert
Within a range of
used pressure
150
PRES.LO ALM
PRES.LO
Low pressure limit alert
0.00
CUR.HI ALM
CUR.HI
High current limit alert
0.0 ~ 40.0 A
40.0 A
CUR.LO ALM
CUR.LO
Low current limit alert
0.0 A