installation & connection
14_
installation & connection
How to connect external cables for each model
Connect external cables by referring the table below.
J
`
Connect alarm input/output cables for each terminals one by one.
TNU-6322ER
Label print
COLOR
Description
Remarks
WAS_NO / PUP
Purple
A terminal to connect Washer Pump (NO)
WAS_NC / ORG
White
A terminal to connect Washer Pump (NC)
GND / GRN
Green
A common terminal to connect external Alarm signal
(GND)
ALARM_COM / BRN
Brown
A common terminal to connect Relay output signal
(COM)
WAS_COM / BLU
Blue
A common terminal to connect Washer Pump (COM)
ALARM_IN / ORG
Orange
A terminal to connect external Alarm signal
ALARM_OUT / YEL
Yellow
A terminal to connect Relay output signal (NC)
AC24V_A
Red
A terminal for 24Vac power supply input (A)
AC24V_B
Black
A terminal for 24Vac power supply input (A)
AC24V_A
Red
A terminal for 24Vac power supply input (A)
AC24V_B
Black
A terminal for 24Vac power supply input (A)
MIC IN
Red
Microphone input port
SPK-OUT
Yellow
Speaker output port
Re)
Gray
Reserved Port(+)
Reserved(–)
Black
Reserved Port(–)
TNU-6322E
Label print
COLOR
Description
Remarks
GND / GRN
Green
A common terminal to connect external Alarm signal
(GND)
ALARM_COM / BRN
Brown
A common terminal to connect Alarm output signal
(COM)
ALARM_OUT / YEL
Yellow
A terminal to connect Alarm output signal
ALARM_IN / ORG
Orange
A terminal to connect external Alarm signal
WAS_COM / BLU
Blue
A common terminal to connect Washer Pump (COM)
WAS_NO / PUP
Purple
A terminal to connect Washer Pump (NO)
WAS_NC / WHT
White
A terminal to connect Washer Pump (NC)
AC24V_A
Red
A terminal for 24Vac power supply input (A)
AC24V_B
Black
A terminal for 24Vac power supply input (B)
MIC IN
Red
Microphone input port
SPK-OUT
Yellow
Speaker output port
Re)
Gray
Reserved Port(+)
Reserved(–)
Black
Reserved Port(–)
Network Cable Specification
Item
Contents
Remark
Connector
RJ45
Ethernet
10/100Base-T
10/100 Mbps
Cable
UTP Category 5e
Max Distance
100M
Power Cable Specification
In case of AC24V Input:
Wire Type (AWG)
#16
#14
Cable Length (Max.)
15 m
24 m