Hanwei JL269LED Скачать руководство пользователя страница 9

- 4 - 

 

 

 

4.5 Open / close audible alarm 

In detecting status, the initial setting of audible alarm is on. The more 

gas leaks, the higher the audible alarm frequency will be. If the detecting 

spot is too noisy, operator can use the earphone purchased by himself.   

Press 

  button can open or close the audible alarm function. 

4.6 Set present level as reference basis 

The gas concentration of the detection field is in gradient distribution. 

In order to find the gas leakage source precisely, during detecting, the user 

can set the present level as reference basis by pressing 

  button. 

4.7 Turn off the detector 

Press both 

  and 

  buttons, the detector will be turned off.   

5. Calibration 

In  order  to  assure  the  accuracy,  it’s  suggested  to  re-calibrate  the 

detector once every 6 months. 

Calibration procedure:   

Hold both 

  and 

  buttons to turn on the detector and the   

detector  will  enters  into  calibration  warm-up  period.  LED  lights  flash  in 

turns showing the warm-up period which will be about 3 minutes. 

After warm-up finish, one green LED light will be lighted on, which 

means the detector enters into zero calibration status. If  the detector is in 

clean  air,  press 

  button  to  save  the  zero  point  information.  Then, 

Power”  light  is  in  green  color  and  3  green  LED  lights  flash.  Zero 

Color 

Voltage 

Green 

Enough 

Yellow 

Not enough 

Red 

Low voltage, need charge 

Содержание JL269LED

Страница 1: ...JL269LED Portable gas leak detector Operation manual Please read this manual carefully before operation Ver HWWM161229CG...

Страница 2: ......

Страница 3: ...g range gas for long time Otherwise it will seriously affect the performance or even damage the device If exposed to the environment consisting of leaded compound sulfur compound organic phosphorus co...

Страница 4: ...s if they have been used for 2 years or charged for 300 times It s forbidden to disassemble adjust or repair the device without permission Please avoid the device falling down from high place or serio...

Страница 5: ...NCTIONS 2 4 OPERATION 2 4 1 Power on 2 4 2 Impact Test 3 4 3 Detecting 3 4 4 Battery voltage check 3 4 5 Open close audible alarm 4 4 6 Set present level as reference basis 4 4 7 Turn off the detector...

Страница 6: ...Automatic zero point adjustment 2 Main technical Specifications Target gas Sensor type Detecting range CH4 semiconductor 0 30000ppm 0 60 LEL 0 3 0 VOL C3H8 semiconductor 0 20000ppm 0 95 LEL 0 2 0 VOL...

Страница 7: ...1 Power on Press and hold for more than 2 seconds the detector will power on and enters into self testing status All LED lights will be lighted on and then off alternately At the same time the buzzer...

Страница 8: ...ble test bar into the gas environment The quantity of LED lights and sound frequency will show the gas concentration With gas concentration increasing first more and more green LED lights will be turn...

Страница 9: ...button 4 7 Turn off the detector Press both and buttons the detector will be turned off 5 Calibration In order to assure the accuracy it s suggested to re calibrate the detector once every 6 months Ca...

Страница 10: ...lor and then turns off The detector will turns off then Note There are more than two calibration points Please carry out calibration in order first zero point calibration and then the second point the...

Страница 11: ...se don t charge them 7 Sensor using and replacement In normal working status the sensor life is 2 years When the sensor is overdue or defective please contact the seller for correct replacement instru...

Страница 12: ......

Отзывы: