background image

 

5.9.5 QPSK Rate 

When internal modulation source is selected, press 

[Mod] > Rate

 softkey to set the rate at which 

the output phase shifts between "carrier phase" and three "modulation phases". 

  Use the numeric keypad or direction keys and knob to input the desired rate value.   

  The rate range is from 2mHz to 1MHz and the default is 100Hz.   

5.9.6 Modulation Phase 

Press 

[Mod]> Phase1

 or 

Phase2/Phase3

 softkeys to set the parameter. 

  Use the numeric keypad or direction keys and knob to input the desired amplitude value.   

  The phase range is from 0º to 360º.The default is 180°. The default values for phases 1, 2, 

and 3 are 45°, 135°, and 225°, respectively. 

 

5.10 3FSK Modulation 

Users  can configure the instrument to "shift" its output frequency between three preset values 

using 3FSK modulation. The rate at which the output shifts between the three frequencies (called 

the "carrier frequency" and two "hop frequencies") is determined by the internal signal level of the 

instrument. 

5.10.1 Select 3FSK Modulation 

Press 

[Mod] >Type > 3FSK

softkey to enable 3FSK function. 

 When 

Mod 

is enabled, 

Sweep 

or 

Burst 

will be disabled automatically. 

 After 3FSK is enabled, the instrument will generate 3FSK waveform with the currently specified 

carrier and modulating waveforms. To avoid multiple waveform changes, enable modulation 

after configuring the other modulation parameters. 

5.10.2 Carrier Waveform Shape 

3FSK carrier shape: Sine (default), Square, Ramp, Pulse, Arbitrary (except DC) or Harmonic 

waveform. 

  Press

[Wave]

 button on the front panel to select the desired carrier waveform. 

  Noise and DC could not be used as carrier waveform. 

5.10.3 Carrier Waveform Frequency 

For different carrier waveforms, the settable range of carrier frequency is different. please refer to 

"Frequency Characteristics" in "

Specifications

".The default value is 1kHz. 

User Manual      48 

Содержание HDG3000BC Series

Страница 1: ...HDG3000B C Series Functions and Arbitrary Waveform Generator User Manual V1 0 1...

Страница 2: ...meter 16 2 2 1 Select the Basic Waveform 16 2 2 2 Set the Frequency 16 2 2 3 Set the Amplitude 17 2 2 4 Set the DC Offset Voltage 17 2 2 5 Set the Start Phase 18 2 2 6 Set the Duty Cycle 19 2 2 7 Set...

Страница 3: ...5 3 5 Modulation Frequency 39 5 3 6 Frequency Deviation 39 5 4 PM Modulation 39 5 4 1 Select PM Modulation 40 5 4 2 Carrier Waveform Shape 40 5 4 3 Carrier Waveform Frequency 40 5 4 4 Modulation Sourc...

Страница 4: ...ct 3FSK Modulation 48 5 10 2 Carrier Waveform Shape 48 5 10 3 Carrier Waveform Frequency 48 5 10 4 Modulation Source 49 5 10 5 3FSK Rate 49 5 10 6 Hopping Frequency 49 5 11 4FSK Modulation 49 5 11 1 S...

Страница 5: ...rst Period 63 7 5 Burst Phase 63 7 6 Trigger Source 63 7 7 Gate Polarity 64 7 8 Trigger Output Edge 64 Chapter 8 Counter 65 Chapter 9 Store 66 9 1 Store System 66 9 2 File Operation 66 Chapter 10 Util...

Страница 6: ...reserves all rights to modify this document without prior notice Please contact Hantek for the latest version of this document before placing an order Hantek has made every effort to ensure the accur...

Страница 7: ...uctor must be connected to earth ground Before making connections to the input or output terminals of the product ensure that the product is properly grounded Connect the probe in a right way The prob...

Страница 8: ...following characters may appear on the product Product Scrapping Device Recycling We need extract and utilize natural resources to produce this device If you do not reclaim the device in a proper way...

Страница 9: ...AM FM PM ASK FSK PSK BPSK QPSK 3FSK 4FSK OSK and PWM modulations Support frequency sweep and Burst output Dual channels can perform internal external another channel modulation and internal external m...

Страница 10: ...G3102B 2 100MHz 300MS s HDG3013C 3 15MHz 300MS s 150MSa s HDG3023C 3 25MHz 300MS s 150MSa s HDG3043C 3 40MHz 300MS s 150MSa s HDG3063C 3 60MHz 300MS s 150MSa s HDG3083C 3 80MHz 300MS s 150MSa s HDG308...

Страница 11: ...nel rear panel user interface and parameter setting method as well as precautions when using the instrument for the first time General Inspection Front Panel Rear Panel Prepare Instrument for Use The...

Страница 12: ...k the instrument In case there is any mechanical damage or defect or the instrument does not operate properly or fails performance tests please notify the franchiser 1 2 Front Panel The content below...

Страница 13: ...his connector output waveform according to the current configuration of the channel 5 Channel ON OFF Enable or disable the output of CH1 or CH2 6 Direction Keys When using the knob and direction keys...

Страница 14: ...utputis enabled this connector outputs the sync signal corresponding to the current settings of CH1 refer to the introduction in Sync ExtMod If modulation mode is enabled for CH1 and external modulati...

Страница 15: ...nternal or external clock refer to the introduction in Clock Source When internal clock source is used the connector used as 10MHz Out can output 10MHz clock signal generated by the internal crystal o...

Страница 16: ...an accept the power supply of 100 120VAC 10 45 440 Hz or 120 240VAC 10 45 66Hz Please use the power cord supplied with the accessories to connect the instrument to the power supply Press the power swi...

Страница 17: ...modified will be highlighted and the red background of the number indicates the current cursor position 3 Waveform Display the selected waveform type of the current channel 4 Channel Configuration Di...

Страница 18: ...irectly input the desired parameter value Decimal point Press this key to insert a decimal point at the current position of the cursor Operator Key The operator key is used to modify the operator of t...

Страница 19: ...ect arbitrary waveform In store and recall use the knob to select the storage location of the file or to select the file to be recalled 1 7 Help To get help information for any front panel keys or men...

Страница 20: ...s separately or from the two channels at the same time At start up the channel is configured as a sine waveform with 1KHz frequency and 200mVpp amplitude by default This chapter introduces how to conf...

Страница 21: ...rrent channel 2 2 2 Set the Frequency Frequency is one of the most important parameters of the basic waveforms For different models and different waveforms the setting ranges of the frequency are diff...

Страница 22: ...it softkey and press Amplitude High Level softkey to switch the Amplitude and Offset in the parameter to High Level and Low level Press Setting High Level or Low Levelsoftkey to modify high level or l...

Страница 23: ...menu that pops up or use the direction keys and the knob to modify the current value 1 For the input method of phase value refer to the introduction in Parameter Setting Method 2 The starting phase ca...

Страница 24: ...square waveformfunction and press Duty softkey to highlight it At this point use the numeric keypad to input the value and select the unit from the unit menu that pops up or use the direction keys and...

Страница 25: ...to the basic parameters such as the frequency amplitude DC offset voltage high level low level and align phase introduced above Pulse width duty cycle Pulse width is defined as the time from the 50 th...

Страница 26: ...the pulse amplitude to fall from 90 threshold to 10 threshold as shown in the figure above The range of the leading trailing edge time is limited by the pulse width currently specified as shown in th...

Страница 27: ...to highlight it Use the numeric keypad to input the offset value 5 and then select the desired unit mV in the pop up menu 6 Press Width softkey to highlight it Use the numeric keypad to input the wid...

Страница 28: ...User Manual 23...

Страница 29: ...of built in waveforms are stored in the internal non volatile memory The user defined arbitrary waveforms can contain 64 to 2M data points Users can edit the arbitrary waveforms via the PC software a...

Страница 30: ...ss Wave Arb Typesoftkeyto select the built in waveform Select more than 160 kinds of arbitrary waveform built in HDG3000B C as shown in the following table Press the softkey and select a type Math Pro...

Страница 31: ...l LFMPulse Linear FM pulse MCNoise Mechanical construction noise Discharge Discharge curve of Ni MH battery Pahcur Current waveform of DC brushless motor Quake Analog quake waveform Radar Analog radar...

Страница 32: ...y profile during starting ISO7637 2 TP5A Automotive transients due to battery disconnect ISO7637 2 TP5B Automotive transients due to battery disconnect SCR SCR firing profile Surge Surge signal Math A...

Страница 33: ...t Square root Tan Tangent TanH Hyperbolic tangent Anti Trigonome ACos Arc cosine ACosH Arc hyperbolic cosine ACotCon Concave arc cotangent ACotPro Protuberant arc cotangen ACotHCon Concave arc hyperbo...

Страница 34: ...en window TaylorWin Taylor window Triang Triangle window Fejer window TukeyWin Tukey tapered cosine window User definedWaveforms Select the user defined arbitrary waveform stored in external storage U...

Страница 35: ...is usually used in the test of harmonic detector device or harmonic filter device This chapter introduces how to configure the generator to output harmonics Subjects in this chapter Overview Set the...

Страница 36: ...ic After finishing harmonic parameter setting press Output1 button or and Output2 button on the front paneland the backlight of the button turns on the instrument outputs the specified harmonic from t...

Страница 37: ...he index number of the harmonic to be selected 2 Amplitude Press thissoftkey to set the amplitude of the selected subharmonic Use the numeric keypad to input the amplitude value and then select the de...

Страница 38: ...carrier waveform and modulating waveform The carrier waveform can be Sine Square Ramp Pulse Arbitrary waveform except DC or Harmonic The modulating waveform can be from internal default other channel...

Страница 39: ...d carrier waveform shape Noise and DC could not be used as carrier waveform 5 1 3 Carrier Waveform Frequency For different carrier waveforms the settable range of carrier frequency is different Please...

Страница 40: ...desired frequency values The modulating waveform frequency range is 2mHz to 1MHz and the default value is 100Hz Note This menu will be grayed out and disabled when other modulation sources except the...

Страница 41: ...z Press Setting Frequency softkey on the front panel and then use the numeric keypad or direction keys and knob to input the desired frequency value 5 2 4 Modulation Source Press Mod Signal Source sof...

Страница 42: ...th The modulation depth represents the degree of amplitude variation expressed as a percentage The modulation depth of DSB AM can be set from 0 to 120 Press Mod Depth softkey to set DSB AM modulation...

Страница 43: ...1kHz Press Setting Frequency softkey on the front panel and then use the numeric keypad or direction keys and knob to input the desired frequency value 5 3 4 Modulation Source Press Mod Signal Source...

Страница 44: ...on must be lower than or equal to the carrier frequency Attempting to set a deviation greater than the carrier frequency will cause the instrument to set the deviation equal to the carrier frequency T...

Страница 45: ...is 1kHz Press Setting Frequency softkey on the front panel and then use the numeric keypad or direction keys and knob to input the desired frequency value 5 4 4 Modulation Source Press Mod Signal Sour...

Страница 46: ...se the numeric keypad or direction keys and knob to input the desired phase values The phase deviation is set to 0 to 360 When external modulation source is selected the phase deviation is controlled...

Страница 47: ...ation Source Internal Source When internal modulation source is selected the modulating waveform is set as a Square with 50 duty cycle and the rate at which the output amplitude shifts between carrier...

Страница 48: ...be disabled automatically After FSK is enabled the instrument will generate FSK waveform with the currently specified carrier and modulating waveforms To avoid multiple waveform changes enable modula...

Страница 49: ...and disabled when the external modulation source is selected 5 6 6 HoppingFrequency The range of hopping frequency depends on the carrier waveform currently selected Refer to Frequency Characteristic...

Страница 50: ...ulation phase is determined by PSK Rate External source When external modulation source is selected the generator receives the external modulating signal from the FSK Trig Sync Extmod connector on the...

Страница 51: ...trary except DC or Harmonic waveform Press Wave button on the front panel to select the desired carrier waveform Noise and DC could not be used as carrier waveform 5 8 3 Carrier Waveform Phase Press S...

Страница 52: ...ment will generate QPSK waveform with the currently specified carrier and modulating waveforms To avoid multiple waveform changes enable modulation after configuring the other modulation parameters 5...

Страница 53: ...ts between the three frequencies called the carrier frequency and two hop frequencies is determined by the internal signal level of the instrument 5 10 1 Select 3FSK Modulation Press Mod Type 3FSKsoft...

Страница 54: ...and knob to input the desired frequency value 5 11 4FSK Modulation Users can configure the instrument to shift its output frequency between four preset values using 4FSK modulation The rate at which...

Страница 55: ...2mHz to 1MHz and the default is 100Hz 5 11 6 HoppingFrequency The range of hopping frequency depends on the carrier waveform currently selected Refer to Frequency Characteristics in Specifications Pr...

Страница 56: ...5 12 3 Carrier WaveformFrequency For different carrier waveforms the settable range of carrier frequency is different Please refer to Frequency Characteristics in Specifications The default value is...

Страница 57: ...y and use the numeric keypad or direction keys and knob to input the desired time The default range is from 8ns to 4 99975ms 5 13 PWM Modulation A modulated waveform consists of a carrier waveform and...

Страница 58: ...he modulation menu is grayed out and disabled The instrument receives the external modulation signal from the FSK Trig Sync Extmod connector on the rear panel The Duty Deviation is controlled by 4V si...

Страница 59: ...ed waveform Duty relative to the original pulse Duty Duty deviation range 0 1 to 49 9 The Duty deviation cannot exceed the current pulse Duty Duty deviation is limited by the minimum Duty and current...

Страница 60: ...e the instrument to output one sweep from start frequency to stop frequency by applying an external or manual trigger The instrument can sweep sine square pulse ramp Harmonic or arbitrary waveforms ex...

Страница 61: ...irection keys and knob to input the desired frequencies By default the start frequency is 100Hz and the stop frequency is 1KHz Different sweep waveform corresponds to different start frequency and sto...

Страница 62: ...tor will restart to output the frequency sweep signal with the specified frequency Note In large scale sweep the amplitude characteristic of the output signal might change 6 4 Linear Sweep HDG3000B C...

Страница 63: ...he next trigger signal When Sweep is enabled pressTrigger Sourcesoftkey to select Internal External or Manual The default is internal Internal The generator outputs continuous sweep waveformat a rate...

Страница 64: ...y is at or greater than the specified mark frequency the signal outputs on the FSK Trig Sync Extmod connector will change from low level to high level External Trigger The FSK Trig Sync Extmod connect...

Страница 65: ...l or manual trigger source supports three kinds of burst types including N cycle Infinite cycle and Gated Burst is allowed with sine square ramp pulse Harmonic noise allowed only in gated burst mode o...

Страница 66: ...e Harmonic Arbitrary waveform except DC Infinite External Manual Sine Square Ramp Pulse Harmonic Arbitrary waveform except DC Gated Ext Sine Square Ramp Pulse Noise Harmonic Arbitrary waveform except...

Страница 67: ...ls the waveform output according to the external signal level from the FSK Trig Sync Extmod connector on the rear panel Press Burst Type softkey to select Gate and then press Polarity to set the gated...

Страница 68: ...all the generator will increase this period automatically to allow the output of the specified number of cycles Press Burst Typesoftkey to select N Cycle PressTrig Srcsoftkeyand select Internal thenpr...

Страница 69: ...not turned on the trigger will be ignored 7 7 GatePolarity Gate polarity is only available in gated burst mode The generator will output burst when the gated signalfrom the FSK Trig Sync Extmod conne...

Страница 70: ...l input signal Press Utility Countersoftkey on the front panel to enablecounter function Input the singal to the Counter connector on the rear panel measure Press Exit softkey or any other key toexit...

Страница 71: ...ormat The state files pho and arbitrary waveform files hwf in the external memory can be recalled The instrument settings state file includes waveform basic parameters Mod Sweep Burst parameters and c...

Страница 72: ...down the knob to input the character In the virtual keyboard rotate the knob to select Capsand press down to switch between uppercase and lowercase rotate the knob to select Shift and press down to sw...

Страница 73: ...tion method of creating a new file After the completion of the denominate press Confirm softkey to confirm the change Delete Use the knob to select the specified file or directory and press Delete sof...

Страница 74: ...r 10 Utility The signal generator allows the user to configure channel parameters configure remote interfaces and set system parameters Sync Impedance Settings System Settings Firmware Update User Man...

Страница 75: ...e first wave point is output the sync is TTL high level The frequency of the sync signal is the frequency of arbitrary waveform For harmonics the sync signal is a square with 50 duty cycle When the fi...

Страница 76: ...ting is HighZ Impedance settings will be displayed on the screen As shown in the figure below the impedance of CH1 is set to HighZ The generator will adjust the output amplitude and offset voltage aut...

Страница 77: ...the clock source would be switched to Internal Users can also synchronize two or more instruments by setting the clock source When two instruments are synchronized the SYNC of phase cannot be used The...

Страница 78: ...y System Informationsoftkey to view the information of the device such as model serial number version number etc 10 3 6 Unit Press Utility Unitsoftkey to select units of waveform parameters Frequency...

Страница 79: ...ick Note The screenshot cached is always the screen at the last time the Utility button was pressed 10 4FirmwareUpdate Copy the firmware to a USB stick FAT32 format storage space is less than or equal...

Страница 80: ...programming Users can program and control the instrument by using the SCPI Standard Commands for Programmable Instruments commands For more information about the commands and programming refer to the...

Страница 81: ...k http hantek com products detail 17187 Or click the following website to download latest one http www keysight com main software jspx ckey 2175637 id 2175637 nid 11143 0 00 l c eng cc GB Double click...

Страница 82: ...Select a Typical and click Next to continue Or select a Custom and click Next to continue User Manual 77...

Страница 83: ...Select Install Keysight VISA as primary VISA and click Next to continue Click Install to start copying files User Manual 78...

Страница 84: ...The installation is completed automatically You will see the running IO program in the lower right corner of the screen User Manual 79...

Страница 85: ...formation of the instrument will also be displayed For example HDG3102C USB0 0x0483 0x5740 0 INSTR 4 Control the instrument remotely 1 Use PC software Users can download the application software packa...

Страница 86: ...earch for the instrument resource currently connected to the PC Click Send Commands To This Instrument to open Keysight interactive IO interface You can send commands and read data For more informatio...

Страница 87: ...Ramp Pulse Noise Harmonic DC Arbitrary Waveforms More than 160 kinds including Sinc Exponential Rise Exponential Fall ECG Gauss Haver Sine Lorentz Dual Tone etc Frequency Characteristics Sine 1uHz 10...

Страница 88: ...g Rate 1uSa s 75MSa s 1uSa s resolution Rise Fall time 9ns Overshoot Typical 1Vpp 5 Harmonic Characteristics Harmonic order 16 Harmonic type Even Odd All The harmonic amplitude can be set for all harm...

Страница 89: ...ise Sinc Exp Fall Haver Sine Lorentz Gause Dual Tone ECG Modulation Frequency 2mHz 1MHz Modulation Depth 0 120 DSB AM Carrier Waveforms Sine Square Ramp Pluse Harmonic Arb except DC Modulation Source...

Страница 90: ...ulation Source Internal External Modulation Waveforms Square with 50 duty cycle Rate 2mHz 1MHz FSK Carrier Waveforms Sine Square Ramp Pluse Harmonic Arb except DC Modulation Source Internal External M...

Страница 91: ...ne Square Ramp Pluse Harmonic Arb except DC Modulation Source Internal Modulation Waveforms 50 duty cycle square wave Rate 2mHz 1MHz OSK Carrier Waveform Sine Modulation Source Internal external OSC T...

Страница 92: ...rst Characteristics Carrier Waveform Sine Square Ramp Pluse Harmonic Arb except DC Carrier Frequency 1uHz 100MHz 1uHz 80MHz 1uHz 60MHz 1uHz 40MHz 1uHz 25MHz 1uHz 15MHz Burst Count 1 2000 000 000 Start...

Страница 93: ...DC coupling Sync Output Level TTL compatible Impedance 50 nominal value CH3 Output HDG3000C series only Standard Waveforms Sine Square Ramp Noise Harmonic DC Arbitrary Waveforms More than 160 kinds in...

Страница 94: ...ty Range 104 40 C 90 relative humidity 106 122 41 C 50 C 60 relative humidity Altitude Operating 3 000 meters No operating 15000 meters Mechanical Dimension 310 x 265 x 110mm L x W x H Weight 2 5 KG A...

Отзывы: