background image

Operating  Data  Logger 

USER’S      MANUAL                                                                                                                                                            33

 

Connect the thermocouple sensor of the metal parts with the tested device. Then, the following 
figure will be displayed on the screen. 

 

Figure 2-23 Temperature Measurement

 

 

Click C key to switch to Fahrenheit. And Click F key to switch to Celsius.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 365A

Страница 1: ...Bluetooth USB Data Logger USER S MANUAL Hantek 365A B C D E F V 1 0 3 www hantek com...

Страница 2: ...16 Chapter 2 Operating Data Logger 21 2 1 Making Voltage Measurement 22 2 2 Making Current Measurement 24 2 3 Measuring Resistance Values 27 2 4 Making a Diode Measurement 28 2 5 Making a Capacitance...

Страница 3: ...source please do not plug in or pull out Check All Terminal Ratings To avoid fire or shock hazard observe all ratings and markings on the product Consult the product manual for further ratings informa...

Страница 4: ...properties DANGER Refer to Protective Chassis grand Earth grand High Voltage the manual Condutor Terminal Terminal System Terms The following terms may appear on the Data Logger Danger The term Dange...

Страница 5: ...Getting Start USER S MANUAL 3 Chapter 1 Getting Start General Check The User interface Install Software Install Driver...

Страница 6: ...ipment have been checked for completeness and the instrument has been checked mechanically and electrically Check the accessories Accessories supplied with the instrument are listed in Accessories in...

Страница 7: ...user interface will be showed as follows Description 1 Data List 2 Description DC DC voltage DC current measurement AC AC voltage AC current measurement Diode measurement On Off test Capacitance meas...

Страница 8: ...acitance button 12 Temperature measurement 13 DC click DC to switch to AC 14 Auto Click Auto to switch to Manual mode 15 Relative Measurement 16 Stop Run Stop or start acquire data 17 Help menu 18 Dat...

Страница 9: ...re before using the Data Logger 1 While in Windows insert the installation CD into the CD ROM drive 2 The installation should start up automatically Otherwise in Windows Explorer switch to the CD ROM...

Страница 10: ...Getting Start USER S MANUAL 8 4 Choose a Setup Type directory Click Next to continue...

Страница 11: ...Getting Start USER S MANUAL 9 5 Check the setup information Click Next to start copying of Files 6 Updating System Configuration 7 The installation is complete...

Страница 12: ...iver 1 Connect the A Type Plug of USB cable to your PC S USB port 2 Connect the B Type Plug of USB cable to Hantek365 s USB port 3 New hardware is found 4 New hardware search wizard starts 5 New hardw...

Страница 13: ...Getting Start USER S MANUAL 11...

Страница 14: ...Getting Start USER S MANUAL 12 6 New hardware wizard installs DRIVER 7 The wizard has finished installing for DRIVER...

Страница 15: ...ting for several seconds install the bluetooth driver automatically Open the computer control panel you will see the bluetooth icon on the lower right corner of the computer 2 Press the switch and the...

Страница 16: ...Getting Start USER S MANUAL 14 3 Next and input the pairing code 1234 the device will be successfully added to the computer...

Страница 17: ...ou will check and remember the COM port number what the bluetooth device uses 5 Run Hantek365 USB there will have a prompt No usb device was found and please click OK Now please click Stop and select...

Страница 18: ...k365E F 1 Inset the Bluetooth adapter to PC USB port After waiting for several seconds right click the unknown device in the device manager to install the Bluetooth driver manually Download the Blueto...

Страница 19: ...Getting Start USER S MANUAL 17...

Страница 20: ...etooth when the indicator stops flashing the connection between Hantek365 and Bluetooth adapter is successful 3 Open the Hantek365 software there will have a prompt No usb device was found and please...

Страница 21: ...Getting Start USER S MANUAL 19 5 Then click open the communication is successful...

Страница 22: ...y has enough power otherwise the communication is unstable 2 Computer built in Bluetooth can not communicate with Hantek365E F And the Bluetooth adapter must be purchased from us to use Bluetooth adap...

Страница 23: ...of a Data Logger This chapter will give guides to show how to use the menus and perform basic measurements Making Voltage Measurement Making Current Measurement Measuring Resistance Values Making a Di...

Страница 24: ...ead into the COM banana jack input and the red lead into the V C banana jack input 3 Connect the red and black leads to the measured points and the voltage value of measured points is displayed on the...

Страница 25: ...key and AC appears on the screen 3 Connect the black lead into the COM banana jack input and the red lead into the V C banana jack input 4 Connect the red and black leads to the measured points and th...

Страница 26: ...Click A key to switch the measurement between mA and A The default is 600mA Click Auto key to switch the measurement range from 60mA to 600mA 2 Connect the black lead into the COM banana jack input a...

Страница 27: ...to the measured points and the DC current value of the measured points will be displayed on the screen 5 Click A to return to 600mA measurement Connect Data Logger probes HT325 with Hantek365 as illu...

Страница 28: ...lowing figure Figure 2 9 Then the following figure will be displayed on the screen Figure 2 10 AC current Measurement for 600mA To measure an AC current which is larger than 600mA follow these steps 1...

Страница 29: ...igure will be displayed on the screen Figure 2 12 AC current Measurement for 10A 2 3 Measuring Resistance Values To measure a resistance follow these steps 1 Click the OHM key and then resistance meas...

Страница 30: ...14 Resistance Measurement 2 4 Making a Diode Measurement To make a measurement on the diode follow these steps 1 Click the Diode key and a diode symbol appears at the top of the screen 2 Connect the b...

Страница 31: ...ow these steps 1 Click the CONTI key and then On Off indictor appears on the top of the screen 2 Connect the black lead into the COM banana jack input and the red lead into the V C banana jack input 3...

Страница 32: ...e steps 1 Click the CAP key and a capacitor symbol appears on the top of the screen 2 Connect the black lead into the COM banana jack input and the red lead into the V C banana jack input 3 Connect th...

Страница 33: ...anual is displayed on the top of the screen 2 Under the manual range mode the measuring range is increased by a stage Click Auto to switch manual 3 Click Manual key to switch back to the automatic ran...

Страница 34: ...played on the top of the screen The saved reference value is displayed beside Then the following figure will be displayed on the screen Figure 2 21 Relative Measurement 2 8 Temperature Measurement The...

Страница 35: ...onnect the thermocouple sensor of the metal parts with the tested device Then the following figure will be displayed on the screen Figure 2 23 Temperature Measurement Click C key to switch to Fahrenhe...

Страница 36: ...Appendix USER S MANUAL 34 Chapter 3 Appendix Appendix A Specifications Appendix B Accessories Appendix C General maintenance...

Страница 37: ...60 00V 10mV 600 0V 100mV 800V 1V AC Voltage 60 00mV 1 3 digit 10uV 600 0mV 100uV 6 000V 1mV 60 00V 10mV 600 0V 100mV DC Current 60 00mA 1 5 1 digit 10uA 600 0mA 1 1 digit 100uA 6 000A 1 5 3digit 1mA 1...

Страница 38: ...365C Yes Yes Hantek365D Yes Yes Yes Hantek365E Yes Yes USB Bluetooth Adapter Hantek365F Yes Yes Yes Connect the device with windows PC via Bluetooth with Bluetooth adapter Connect with iPad via Blueto...

Страница 39: ...7 Appendix B Accessories Standard accessories Data Logger Probes x 2 A USB Cable A PC software CD of the Data Logger A Thermocouple Sensor Optional accessory Bluetooth adapter Optional accessory for H...

Страница 40: ...id damages to the surface of the device or probes not use any abrasive or chemical cleaning agents Cleaning Inspect the device and probes as often as operating conditions require Make sure the device...

Отзывы: