Table 2-1 AP interface and function description 

Interface 

Name 

Functional description 

Power source 

adaptor interface 

12V-1A  standard  adapter  access,  Hanshow  provide  standard 

12V adapter 

Reset button 

Restore factory settings button

Press this button for more than 

5  seconds,  the  configuration  can  be  reset.  After  reset,  the 

system  automatically  loads  the  default  settings;  do  not  need  to 

restart  the  ESL  Access  Point.  Factory  parameter  see 

"Configuration Guide"  

USB Interface 

Type A USB interface, standard USB device is adapted. 

 

Ethernet interface 

Standard 100M Ethernet interface, connected to customer 

system via wire. POE powered supported. 

Two digits Nixie 

light 

Green,  and  displays  Access  Point  ID.  (The  direction  of  Nixie 

light  is aligned  to  interface  direction.  The Nixie  light  is  correctly 

displaying when interfaces is facing up) 

 

5 LED lights 

5 LED indicators for working status 

One digit Nixie 

light 

Red indicates the Access Point condition. (The direction of Nixie 

light  is aligned  to  interface  direction.  The Nixie  light  is  correctly 

displaying when interfaces is facing up) 

 

ESL Access Point 

antenna 

Four antennas for 2.4GHz wireless communication.  

Can support synchronous transceiver mode, this mode is 

completely controlled by the system, do not need artificial 

configuration 

Содержание HS_C09851

Страница 1: ...Document Symbol Number HS AP PR001 ESL ACCESS POINT HS_C09851 PRODUCT MANUAL Document Version 01 Release Date 2016 09 30 ALL RIGHTS RESERVED...

Страница 2: ...is manual is applicable for the below engineers Test Engineer Technical Support Engineer After Sale Technical Support Engineer Symbolic Description Icon Description Reader should pay better attention...

Страница 3: ...5 2 1 Overview 5 2 2 Configuration and Appearance 6 2 2 1 Basic Configuration 6 2 2 2 Physical interface 7 2 2 3 AP Appearance Parameters 10 3 ESL ACCESS POINT INSTALLATION 11 3 1 1 Installation requ...

Страница 4: ...Main processing system Embedded Linux operating system responsible for data interaction with ESL Working system including ESL Access Point system s registration heartbeat reception data transmission R...

Страница 5: ...specification based on the ESL radio protocol standard to ESL Working platform to forward ESL heartbeat and other information 1 3 HS C09851 Characteristics Linux OS Embedded Linux operating system su...

Страница 6: ...MHz ARMprocessor Storage 512M FLASH 512M RAM OS Embedded Linux system RF 2 4G Module Working Freq 2 402 2 480GHz Channel bandwidth 500KHz Modulation GFSK Transmission rate Uplink 500K bps Downlink 100...

Страница 7: ...interface Figure 2 1 Appearance of second generation ESL Access Point Note ESL Access Point antenna different batches will be different without affecting the transmission performance 1 2 4 5 7 6 8 3 F...

Страница 8: ...ce is adapted 4 Ethernet interface Standard 100M Ethernet interface connected to customer system via wire POE powered supported 5 Two digits Nixie light Green and displays Access Point ID The directio...

Страница 9: ...ess Point range 1 99 Off The ESL Access Point is not connected 2 3 4 5 RF module indicator On The corresponding radio module is in the receive data state Off The corresponding radio module is in the i...

Страница 10: ...g IP address can be modified on configuration page 2 2 3 AP Appearance Parameters Table 2 4 ESL Access Point appearance parameters Materials Face shell and bottom shell ABS plastic material Indicator...

Страница 11: ...d coverage as shown in Figure 3 1 Figure 3 1 ESL Access Point installation diagram Note the H in the diagram is suggested to be between 3 to 3 5 meters to cover a area of raduis of 15 meters 3 1 2 Acc...

Страница 12: ...RF sub system embedded processing unit individual RF module 2 Display Nixie light and LED display for Access Point ID working condition and error code display 3 Interface power source reset button US...

Страница 13: ...gin coorespoding webpage via IP address to modify the settings of Access Point For example login http 192 168 51 100 for the Access Point IP address is 192 168 51 100 Figure 5 1 ESL Access Point confi...

Страница 14: ...Please plug in the power source and network wire 2 The system is working when the Access Point is powered by either 12V DC or POW adaptor and green light is on 3 The starting up time is approximately...

Страница 15: ...d 5 screws 8 NOTICE OF PERATION 8 1 Installation Caution Please use the standard power adapter Installation height of 3 to 3 5 meters ESL Access Point covers a radius of 15 meters ESL Access Point to...

Страница 16: ...reasonable protection against harmful interference in a residential installation This equipment generates uses instructions may cause harmful interference to radio communications However there is no...

Отзывы: