Hanshow ESL Controller HS_C09978 Product Manual
24 Hanshow Copyright Reserved ©
Hanshow Technology Co., Ltd.
Item
Description
Installation distance
⚫
If the shelf height is
≤
3m, recommended the installation distance
of two Hanshow APs is about 22m, and at least 5m.
⚫
If the shelf height is 3m ~ 5m, it is recommended that the
installation distance of two Hanshow APs is about 18m and at least
5m.
⚫
If shelf height exceeds 5m, the installation height of AP is
determined according to the actual situation.
⚫
The installation height of AP should be higher than shelf height to
avoid signal occlusion.
⚫
For Horizontal hanging suspension from the ceiling, recommended
the installation distance is more than 6cm away from the ceiling.
Network settings
⚫
Wi-Fi AP 5GHz frequency band is suggested to replace 2.4GHz
frequency band for Wi-Fi coverage.
⚫
If Wi-Fi AP is 2.4GHz, recommended to set Wi-Fi channel to 1, 6
or 11.
⚫
If Wi-Fi AP is 2.4GHz, recommended to stagger the update time
with ESLs to achieve optimal performance.
⚫
Hanshow AP may be limited or affected by other IoT devices that
share the 2.4GHz frequency-band such as Wi-Fi, BT or Zigbee.
Post-installation check
⚫
Install the AP firmly on the ceiling to avoid AP falling off and
damaged.
⚫
The power cable or network cable is intact and not spliced.
⚫
The AP runs properly.