Hanshen TIG200P Скачать руководство пользователя страница 11

10

current”, it is always selected in a lesser value which can protect arc not breaking).

c.

Open up the valve of argon bottle and adjust the flowmeter to the needed value.

d.

Set post flow gas time:

A

djusting post flow gas time means that argon gas can be turned off later for a proper time after

welding being finished and arc being broken. It can more really protect the workpiece and guarantee
the quality of welding. The detail operation is: adjust the “post flow gas time” knob and select
needed value among 1-10 seconds according to the value of welding current (summit current).

Generally speaking,

the bigger welding current or the higher welding quality is, the longer post

flow gas is; otherwise, the smaller or the lower is, the shorter is for saving gas.
The more the “post flow gas time” knob is rotated in clock-wise direction, the more post flow gas
time is increased.

6. WELDER OPERATING

MMA welding:

After all switches and knobs are checked in correct situation on the base of item 5.4, adjust “current
adjusting” knob according to thickness of workpiece, select the proper welding current and rods,
then begin to formally weld.

AC TIG welding:

a. According to item 5.4 check whether all switches and knobs are in correct situation.
b. After rotating the knob “base current”

to the end

in clock-wise direction, select the proper

welding current by adjusting knob “current adjust”.

c. Press the switch on torch and ignite arc by HF. The arc is automatically extinguished after

loosening the torch switch. The post-flow time can be adjusted among 1-10 seconds. Close
the argon bottle and turn off the welder after welding.

Содержание TIG200P

Страница 1: ...hat all installation operation maintenance and repair procedures are preformed only by qualified individuals Read this operators manual completely before attempt to use this equipment Save this manual...

Страница 2: ...cteristics applications 2 2 Safety attention 2 3 Range of welding parameters 4 4 Installing and connecting 4 5 Prepare for welding 7 6 Weld operating 10 7 Daily maintain check 12 8 Trouble shoot 12 9...

Страница 3: ...with application of HF technique F Its protection is perfect with over current and over heat protection slow startup of current anti strike G The welder is much smaller lighter and with high efficienc...

Страница 4: ...Only after disconnection of power and safety ensuring the connection of welder can be operated 2 Don t touch the parts with electricity or wear the wet broken gloves 3 The cables should be selected a...

Страница 5: ...Hz 0 5 200 Pulse rate 0 1 0 9 Post flow time s 1 10 dimensions W D H mm 430 195 380 Weight Kg 18 4 INSTALLING CONNECTING 1 POSITION FOR USING place the welder on the dry clean and solid smooth ground...

Страница 6: ...g the lack of oxygen when weld is operated in close space 4 POWER SUPPLY EQUIPMENT CONNECTIONS table 2 power supply equipment connections mode TIG200P Input voltage V 1 phase 220 10 Capability KVA 7 5...

Страница 7: ...6 p i c t u r e 1 c o n n e c t i o n f o r T I G w e l d i n g p i c t u r e 2 c o n n e c t i o n f o r M M A w e l d i n g...

Страница 8: ...ECTION Connect the welder according to the pictures1 3 and the requirements in 4 6 for welding ATTENTION input voltage should be 1 phase 220V 2 TUNGSTEN PORCELAIN SPIGOT ARGON FLUX Select the proper t...

Страница 9: ...List4 welding parameter of stainless steel Workpiece thickness mm Tungsten dia mm Filling Wire dia mm Welding current A Argon flux L min groove condition Nozzle dia mm 0 4 1 0 1 6 1 0 8 20 3 4 A or B...

Страница 10: ...e power indicator turns light and the fan runs it means the machine has been normally started b Selection of welding mode MMA welding Turn the switch MMA TIG to position MMA and rotate the base curren...

Страница 11: ...ller or the lower is the shorter is for saving gas The more the post flow gas time knob is rotated in clock wise direction the more post flow gas time is increased 6 WELDER OPERATING MMA welding After...

Страница 12: ...p and cooled down quickly the possibility of producing cracks can be decreased It is suitable for welding workpieces which are of different heat conductivity and thickness and thin plates and ultra th...

Страница 13: ...reference for examination Item of circuitry examination Regular examination for 1 or 2 months 1 Function of power switch 2 If the running of cooling fun is in normal condition 3 If exists unwonted li...

Страница 14: ...r the circuitries are in correct connection In order to avoid troubles do not energize hard and change its position at will while connecting List7 overhauling items Trouble phenomena Trouble causes No...

Страница 15: ...itor Voice of HF discharging exists inside machine Overheat protection or overflow protection Turn off the mcahine for a few minutes and retry Tungsten electrode is far away from workpiece Keep the di...

Страница 16: ...not enough Ensure the capability of power supply more than the maximal power of machine in normal work condition Function pulsed TIG welding does not exist One of the base current summit current or pu...

Страница 17: ...16 9 CIRCUIT DIAGRAM...