Assembly see page 60
Protected area
(see page 60)
Exchange battery
(see page 64)
Safety Function
(see page 61)
The desired maximum temperature for example max. 38ºC can be pre-
set thanks to the safety function.
Cleaning
(see page 65) and enclosed brochure
Never use high pressure cleaners or steam cleaners to clean the fittings.
Cleaning washbasin
(see page 64)
After setting the parameters for the hygiene rinse or making a net reset,
wait for approx. 90 s before you can enable the "Clean wash basin"
function.
Spare parts
(see page 66)
Flow diagram
(see page 62)
with EcoSmart
®
without EcoSmart
®
Dimensions
(see page 62)
Do not use silicone containing acetic acid!
Symbol description
English
Technical Data
This mixer series-produced with EcoSmart
®
(flow limiter)
Operating pressure:
max. 0,8 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Maximum flowing-out temperature at 50 K temperature difference and 0,3 MPa
flow pressure:
approx. 42°C
Follow-on time:
1 - 2 sec.
Automatic switching-off:
after 10 sek.
battery:
CR-P2 / 6 V Lithium
transformer:
230 V AC ± 10 % / 50 – 60 Hz / 20 mA
Protection class:
IPX5
installation site of type plate:
see page 66
The product is exclusively designed for drinking water!
Test certificate
(see page 62)
Operation
(see page 63)
Hansgrohe recommends not to use as drinking water the first half litre
flowing from the tap in the morning, after the hygiene rinse is enabled,
or after prolonged non-use. The hygiene rinse opens the tap for 10
seconds every 24 hours following the last operation.
Hygiene rinse
To enable or disable the hygiene rinse, proceed as follows:
• Interrupt voltage supply of the fittings for approx. 10 s (disconnect
electrical plug connection between fittings and battery housing or
power pack and reconnect after 10 s)
• The LED blinks to indicate the software version (e.g. blinking once =
software version 1)
• permanent light from the LED indicates that calibration of the infrared
proximity electronics is in progress
• wait for LED to go out
• cover sensor window completely with your hand or a white piece of
paper
• Remove your hand or the paper after 10 s
• the currently enabled mode is indicated by the flashing of the LED: 1
x = enabled, 2 x = disabled
Permanent rinse
After setting the parameters for the hygiene rinse or making a net reset,
wait for approx. 90 s before you can enable the "Permanent rinse"
function.
• cover sensor window completely with your hand or a white piece of
paper
• The tap opens briefly and then closes immediately. When the tap
opens again after approx. 5 s, remove the hand or the paper from
the sight glass.
• Permanent rinse is enabled for 180 s and can be interrupted at any
time by a movement in the field of vision.
Thermal disinfection
• Thermal disinfection pursuant to process sheet DVGW W 551(≥
70°C / > 3 min) must only be carried out by qualified personnel.
• Risk of scalding with thermal disinfection!
• The cold water feed must be locked during thermal disinfection.
Afterwards, "Permanent rinse" can be enabled.
Net reset
A net reset causes the fittings to re-adjust
• Interrupt the voltage supply to the fittings
• Briefly reach into the field of vision of the fittings to cause the capaci-
tor to discharge
• Wait for approx. 10 s, then plug the connectors in again
• The fittings will re-adjust during the next 30 s. Do not reach into the
field of vision during this period of time.
Maintenance
(see page 65)
The check valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least once
a year).