Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pressu-
res.
Installation Instructions
The fitting must be installed, flushed and tested after
the valid norms.
If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
®
(flow limiter) located behind the aerator can be
removed.
Technical Data
This mixer series-produced with EcoSmart
®
(flow
limiter)
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
•
•
English
Cleaning
(see page 37) enclosed
brochure
Operation
(see page 36)
Spare parts
(see page 38)
Assembly see page 31 + 32
Dimensions
(see page 34 + 35)
Do not use silicone containing acetic acid!
Special accessories
special tool (58085000) order as an extra
Installation kit order as an extra
To adjust the hot water limiter on single lever
mixers, please see page 33. No adjustment
is necessary when using a continuous flow
water heater.
Symbol description
Flow diagram
(see page 34 + 35)
with EcoSmart
®
without EcoSmart
®
Test certificate
(see page 39)
Содержание Citterio M 34010000
Страница 31: ...31 1 4 5a SW 11 mm SW 19 mm 2 3 5b SW 19 mm...
Страница 32: ...32 58085000 10 11 12 11 9 6 7 58085000 8 9 11...
Страница 33: ...33 60 C 10 C 0 3 MPa 0 3 0 3 1 3 2 5 6 7 SW 3 mm SW 3 mm 2 x SW 3 mm 4...
Страница 35: ...35 Citterio M 34210000 Citterio M 34014000 Citterio M 34210000...
Страница 37: ...37 1 2...