Start instructions (force-feed lubrication, integrated pump)
Procedure
1. Delay the alarm signal, to stop the motor that operates the gear unit when the oil flow
is low, with 5 s. If not, unwanted alarms occur during startup.
2. For more instructions, refer to the service manual of the lubrication and cooling
system.
Start instructions (drive group with a 2-speed motor)
Procedure
1. Before you change from the higher to the lower speed, decrease the speed below
the lower speed.
Then, the motor must increase the speed to the lower speed. This condition prevents
that the torque to the gear unit becomes too high.
Instructions after commissioning
Warning: Do not disassemble an "OIL-LOCK
TM
" or the "OIL-GUARD
TM
"
system on the HSS. If you see leaks at this location, speak to H.I.T.
Procedure
1. Do a check on the gear oil level. Refer to section
40.
2. While the gear unit operates, listen for unexpected noise and vibrations.
3. If you hear unexpected noise and vibrations, remove the source of the unexpected
noise and vibrations.
Warning: Do not remove the safety covers.
4. Examine the surface of the gear unit and the adjacent parts.
5. If you see leakage: find and remove the cause of the leakage.
6. Clean all parts that have gear oil or grease on the surface.
7. Make sure that the gear unit operates until the temperature is constant (ΔT < 1 °C / 1
h)
8. Make sure that the gear unit is aligned correctly. Refer to section
on page 31.
Warning: Do not touch the gear unit. It is hot. Use protective clothing
9.6
9.7
9.8
Commissioning
IM_405_002_EN
45