Define the installation space
WARNING
Risk of injury!
Improper installation of the appliance
can lead to injury.
■
At the point where the exhaust hood
is installed, the ceiling or wall must
have a load-bearing capacity of at
least 40 kg and must be at least 30
mm thick to provide suffi cient sup-
port for wall plugs or heavy-duty an-
chors.
■
Before drilling the holes, ensure that
no wires or cables (power, gas, water
etc.) will be damaged (check with a
line locator).
■
Only use mounting materials that are
suitable for the characteristics of the
ceiling and walls. If you are not sure
of your selection, ask a professional
for guidance.
CAUTION
Fire hazard!
■
The distance between the cooking
surfaces and the lower edge of the
Exhaust hood must be at least 65 cm
for gas cookers.
■
For gas stovetops, you must read the
user manual for the stovetop! If the
manual stipulates a larger distance,
this must be observed.
(a)
1. To place the appliance exactly over the
centre of the cooker, use a straight line
(a) to determine the point on the ceiling
above the centre of the cooker.
6
2. Place the centre of the base plate 6 on
this point and mark the twelve drill holes.
3. If the exhaust hood is to be used for ex-
haust air operation, also mark the open-
ing for the exhaust air hose on the ceiling.
4. Drill holes into the marked spots with a di-
ameter that corresponds to the wall plugs.
5. Insert twelve wall plugs into the drilled
holes.
Assembly
Assembly
Page GB-14