![Hanseatic HKS17660VGA2G Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/hanseatic/hks17660vga2g/hks17660vga2g_user-manual_4058586055.webp)
Space required according to the appliance
dimensions
A:
1769 mm
B:
605 mm
C:
---
D: 635 mm
E:
1150 mm
F:
N:24 T:38
G:
---
H: 115 °
I:
852 mm
– To prevent the formation of a flammable
gas-air mixture in the event of a leakage
in the refrigeration circuit, the installation
space must have a minimum size of 1 m
3
per 8 g of refrigerant in compliance with
the EN 378 standard. The amount of re-
frigerant contained in your appliance can
be found on the data sheet at the end of
this user manual.
– The appliance must only be placed on a
level and firm surface. The surface must be
strong enough to support the appliance’s
weight when fully laden.
– Suitable locations are dry, well-ventilated
areas that are cool if possible.
– Unsuitable locations are ones with direct
sunlight or which are directly next to an
oven, hob or radiator.
–
WARNING!
Your appliance should be at
least 50 cm away from stoves, gas ovens,
and heater cores, and at least 5 cm away
from electrical ovens.
When your fridge is placed next to a deep
freezer, there should be at least 2 cm bet-
ween them to prevent humidity forming on
the outer surface.
– If you would like to reduce these distances,
you can fit an insulation plate between the
appliances.
Space requirement diagram (when the door is open and when the door is closed)
Start-up
Page GB-23