Space required according to the appliance
dimensions
A:
1901 mm
B:
605 mm
C:
---
D: 681 mm
E:
1200 mm
F:
30 mm
G:
---
H: 120 °
I:
900 mm
– To prevent the formation of a flammable
gas-air mixture in the event of a leakage
in the refrigeration circuit, the installation
space must have a minimum size of 1 m
3
per 8 g of refrigerant in compliance with
the EN 378 standard. The amount of re-
frigerant contained in your appliance can
be found on the nameplate and in the data
sheet at the end of this user manual.
– The appliance must only be placed on a
level and firm surface. The surface must be
strong enough to support the appliance’s
weight when fully laden.
– Suitable locations are dry, well-ventilated
areas that are cool if possible.
– Unsuitable locations are ones with direct
sunlight or which are directly next to an
oven, hob or radiator.
–
WARNING!
Your appliance should be at
least 50 cm away from stoves, gas ovens,
and heater cores, and at least 5 cm away
from electrical ovens.
When your fridge is placed next to a deep
freezer, there should be at least 2 cm bet-
ween them to prevent humidity forming on
the outer surface.
– If you would like to reduce these distances,
you can fit an insulation plate between the
appliances.
– If underfloor heating is installed at the set-
up location, place the cooling appliance on
Space requirement graphic (when the door is open and when the door is closed)
Start-up
Page GB-24