Start-up
Page EN-16
Space requirement
D
E
F
G
G
H
I
C
A
B
A:
550 mm
B:
835 mm
C:
100 mm
D:
555 mm
E:
1045 mm
F:
100 mm
G:
50 mm
H:
180 °
I:
1085 mm
■
Always ensure that the ambient tem-
perature remains within the specifi ed
range (see product data sheet at the
end of this user manual)
– To prevent the formation of a flammable
gas-air mixture in the event of a leakage
in the refrigeration circuit, the installa-
tion space must have a minimum size of
2.2 m³.
– The appliance must only be placed on a
level and firm surface. The surface must be
strong enough to support the appliance’s
weight when fully laden.
– Suitable locations are dry, well-ventilated
areas that are cool if possible.
– Unsuitable locations are ones with direct
sunlight or which are directly next to an ov-
en, hob or radiator.
The following minimum distances must be
maintained:
– from electrical hobs
50 mm
– from oil and coal-fired stoves
300 mm
– from other refrigerating appli-
ances
50 mm
– from washing machines/
dishwashers
50 mm
If you would like to reduce the distance to
oil or coal-fired stoves, you can fit an insu-
lation plate between the appliances.
– If underfloor heating is installed at the set-up
location, place the refrigerating appliance on