Start-up
Page EN-22
Choosing a suitable location
CAUTION
Health hazard!
The appliance may not operate proper-
ly if exposed to low ambient tempera-
tures for extended periods of time. This
can then lead to an increase in temper-
ature in the fridge and freezer.
■
Always ensure the prescribed am-
bient temperature is maintained
(see "Intended use" on page EN-4).
Dangers from the refrigerant!
■
Do not damage the refrigeration cir-
cuit, for example by piercing the re-
frigerant channels of the condensate
vaporiser with sharp objects, cutting
off the tubing, etc.
■
To prevent a fl ammable gas-air mix-
ture from forming following a leak-
age in the refrigeration circuit, the
installation space must have a min-
imum size of 1 m
3
per 8 g of refrig-
erant in compliance with the EN 378
standard. The amount of refrigerant
contained in your appliance can be
found on the data sheet (see "Techni-
cal specifi cations" on page EN-31).
■
Refrigerant is fl ammable when spurt-
ing out and can damage the eyes. In
this case, rinse your eyes in clean wa-
ter and seek medical assistance im-
mediately.
• Choose a suitable position with a mini-
mum capacity of: 11.2 m
3
• Place the appliance on as flat and as firm
a base as possible. Adhere to the pre-
scribed
minimum distances
(see next
page).
• Make sure that the ambient temperatures
match the climate category of the appli-
ance (see "Intended use" on page EN-4).
– Suitable locations are dry, well-ventilated
areas that are cool if possible.
– Unsuitable locations are ones with direct
sunlight or which are directly next to an
oven, hob or radiator.
About climate categories
• Always ensure the prescribed ambient temperature is maintained (see "Intended use" on
page EN-4).
Climate category means that the appliance is intended for operation at the specified ambient
temperature.
Zone description
Code Definition
Extended temperate zone
SN
This refrigerator is designed for use at ambient temper-
atures of +10 °C to +32 °C.
Temperate zone
N
This refrigerator is designed for use at ambient temper-
atures of +16 °C to +32 °C.
Subtropical zone
ST
This refrigerator is designed for use at ambient temper-
atures of +16 °C to +38 °C.
Tropical zone
T
This refrigerator is designed for use at ambient temper-
atures of +16 °C to +43 °C.
If the room temperature drops significantly below this, the unit will not switch on as often. This
indicates that an unwelcome increase in temperature may occur.