3
Hot tub performance specifications
1 Hot tub performance specifications
Performance specifications
nominal voltage:
three-phase connect 230/400 V 50 Hz*
maximum work current:
3× 16 A
current surge:
up to 3× 25 A
voltage resistance:
1 250 V/min without puncturing
insulation resistance:
>= 1 M Ω
water resistance:
IPX5
electrical shock protection:
first level
* The product does not use 400 V phase to phase voltage. It is possible to adjust it to
1× 230 V; however, this is not recommended due to limitation of the functions.
(For more information on this connection, please refer to the Supplements, p. 22)
Stress load
heating:
1× 230 V/3 kW/13 6 A
ozone:
1× 230 V/50 Hz /80 mA
blower:
1× 230 V/0 66 kW/2 9 A
circulation pump 1/1 + 1/1:
2 2 kW + 2 2 kW + 0 4 kW
overall wattage (depends on the hot tub type): 8 5 kW / h
protection class:
I
lighting:
LED 12 V/10 W
maximum output:
20 W
humidity resistant speakers:
yes
Preparation and electrical connection options – AC three-phase
current 3× 230/400 V/16 A/20 A
Ensure that the hot tub is always connected to a circuit protected by a Residual Current
protective Device with a rated tripping current of 0,03 A. It is necessary to use
For your own safety and the safety of your product, please observe the
following instructions Read the following information carefully and follow
the user manual exactly when using the hot tub to avoid damaging the product
or the risk of injury This appliance is intended for use by children 8 years of
age or older with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, provided they are under supervision or have been
instructed on the use of the product and understand the risks Children must
not play with the product Cleaning and maintenance must not be performed by
children without supervision