![Hans Grohe Talis Classic 14140 Series Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/hans-grohe/talis-classic-14140-series/talis-classic-14140-series_quick-start-manual_2102464007.webp)
English
Assembly
Attention!
The fitting must be installed, flushed and
tested after the valid norms.
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
The hot and cold water supply’s should be of equal
pressures.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure: 0.1 - 0.5 MPa
Test pressure:
1.6 MPa
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
max. 80° C
Recommended hot water temp.: 65° C
Centre distance:
150 ± 12 mm
Connections G ½”:
cold right - hot left
Rate of flow:
approx. 18 l/min
Anti-pollution function
To adjust the hot water limiter on single lever
mixers, please see page 14.
No adjustment is necessary when using a continuous
flow water heater.
Hansgrohe single lever mixers can be used toge-
ther with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0.15 MPa.
Attention!
The non return valves must be checked regularly ac-
cording to DIN EN 1717 in accordance with national
or regional regulations (at least once a year).
Spare parts
(see page 4)
1 handle
14193XXX
1.1 screw cover
96338000
2 flange
97406XXX
3 nut
97209000
4 cartridge cpl.
92730000
5 flange
96346XXX
6 S-unions
94140000
7 aerator cpl.
13914XXX
8 selector assy
97978000
9 diverter knob
97981XXX
10 non return valve DW 15
94074000
11 noise reduction
96429000
12 sleeve
97979XXX
13 seal
95008000
14 non return valve
97980000
XXX
= Colors
000 chrome plated
820 brushed nickel
Fault
Cause
Remedy
Insufficient water
- Shower filter seal dirty
- Non return valve hasn’t moved
back
- Clean filter seal between shower
and hose
- Exchange non return valves
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Hot water temperature too low
- Hot water limiter incorrectly set - Set hot water limiter
Instantaneous heater didn’t work - Flow limiter in handshower isn’t
removed
- Filter are dirty
- Non return valve didn’t move back
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange non return valves