background image

English

Attention! 

The fitting must be installed, flushed 

and tested after the valid norms.

Assembly

1.  Flush through the supply pipes.

2.  Mount the S - unions and align them.

3.  Fasten the mixer with the washers.

Large differences in pressure between the hot and 

cold water supply should be balanced.

Operation

The mixer is actuated by lifting the lever head.

Swivel to the left = hot water, swivel to the right = 

cold water.

33144000/33143000: The flow is changed from 

bath to shower function by pulling the knop at the 

upper side of the spout. After shutting off the water 

flow,  the  mixer  returns  automatically  to  the  bath 

function.

Technical Data

Operating pressure: 

max. 1 MPa

Recommended operating pressure:  0.1 - 0.5 MPa

Test pressure: 

1,6 MPa

(1 MPa = 10 bars = 147 PSI)

Hot water temperature: 

max. 80° C

Recommended hot water temp.: 

65° C

Centre distance: 

150 ± 16 mm

Connections G ½": 

cold right - 

 

hot left

Rate of flow 0.3 MPa: 

approx. 20 l/min

Back flow and vacuum breaker

Hansgrohe  single  lever  mixers  can  be  used  tog-

ether with hydraulically and thermically controlled 

continuous  flow  heaters  if  the  flow  pressure  is  at 

least 0.15 MPa.

To  adjust  the  hot  water  limiter  on  single  lever 

mixers, please see page 15.

No  adjustment  is  necessary  when  using  a  conti-

nuous flow water heater.

Attention!

The  non  return  valves  must  be  checked  regularly 

according  to  DIN  EN  1717  in  accordance  with 

national  or  regional  regulations  (at  least  once  a 

year).

Spare parts 

(see page 3)

handle 

33092000

1.1  screw cover 

96338000

flange 

96656000

nut 

96690000

cartridge, assy 

92730000

locking screw 

96059000

escutcheon Ø 68 mm 

96467000

ball S - unions (2) 

94140000

noise reduction (2) 

96429000

aerator cpl. (10) 

13956000

10  selector assy 

94077000 

11  diverter knob 

96466000

12  non return valve DW 15 (10)  94074000

13  hose connection 

96044000

Fault

Cause

Remedy

Insufficient water

-  Shower filter seal dirty

-  Filters dirty 

-  Non return ralve didn't move 

back

-  Clean filter seal between sho-

wer and hose

-  Clean the filter/exchange filter

-  Exchange non return valves

Mixer stiff

-  Cartridge defective

-  Exchange cartridge

Mixer dripping

-  Cartridge defectiveSedimentati-

on

-  Exchange cartridge

Hot water temperature too low

-  Hot water limiter incor-rectly set -  Set hot water limiter

Instantaneous heater didn't work  -  Flow limiter in handshower isn't 

removed

-  Filter are dirty

-  Non return valve didn't move 

back

-  Remove flow limiter 

-  Clean the filter/exchange filter

-  Exchange non return valves

6

Содержание Talis C 33144000

Страница 1: ...Telefon 04621 30 60 89 0 Mail info unidomo com ffnungszeiten Mo Fr 8 00 17 00 Uhr a member of DAIKIN group Individuelle Beratung Komplettpakete Kostenloser Versand ber 15 Jahre Erfahrung Hochwertige...

Страница 2: ...Talis C 33144000 Talis C 33161000 Talis C 33163000 Talis C 33143000 Montageanleitung...

Страница 3: ...33144000 33161000 33143000 33163000 DIN 4109 PA IX 9362 IBB 33144000 DIN 4109 PA IX 9361 IB 33161000...

Страница 4: ...Aanslutningen Eksenteranslutningen Exc ntrico Przy cze S S 10 12 12 13 8 8 36 Silikon essigs urefrei Silicone sans acide ac ti que Silicone free from acetic acid Silicone esente da acido acetico Sili...

Страница 5: ...ause durch Ziehen am runden Knopf auf der Oberseite des Auslaufs Die R ckstellung erfolgt nach Schlie en des Griffes automatisch Technische Daten Betriebsdruck max 1 MPa Empfohlener Betriebsdruck 0 1...

Страница 6: ...emp rature pour le r glrage voir page 15 Une limitation de la temp rature n est pas n ces saire quand le mitigeur est aliment par un chauf fe eau instantan Attention Les clapets anti retour doivent tr...

Страница 7: ...adjust the hot water limiter on single lever mixers please see page 15 No adjustment is necessary when using a conti nuous flow water heater Attention The non return valves must be checked regularly a...

Страница 8: ...ore duro Cartuccia difettosa Sostituire la cartuccia Miscelatore gocciola Cartuccia difettosa Sostituire la cartuccia Temperatura dell acqua calda Limitazione dell acqua calda regolata male Regolare l...

Страница 9: ...con limitaci n del caudal de agua caliente ajuste ver pagina 15 En combianci n con calentadores instant neos no es necesario una limitaci n del caudal de agua caliente Atenci n Las v lvulas anti retor...

Страница 10: ...gslagklep uitwisselen bediening zwaar Kardoes defect of verkalkt Kardoes uitwisselen mengkraan lekt Kardoes defect Kardoes uitwisselen Temperatuur van warm water te laag Heetwaterbegrenzer verkeerd in...

Страница 11: ...ring se side 15 I forbindelse med gennemstr mningsvandvarmer er en varmtvandsbegr nsning ikke n dvendig Bem rk If lge DIN EN 1717 skal gennmestr mningsbe gr nsere i overenstemmelse med nationale regle...

Страница 12: ...de 0 15 MPa Misturadora momocomando equipada com limita dor de temperatura vide p g 15 Importante As v lvulas anti retorno devem ser verificadas regularmente de acordo com a DIN EN 1717 segundo os reg...

Страница 13: ...65 C Pod czenia 150 16 mm Przy cza Zimna prawo ciep a lewo Przep yw 0 3 MPa o 20 l min Zabezpieczenie przed przep ywem zwrotnym Mieszacz jednouchwytowy z ograniczeniem wody gor cej justowanie patrz s...

Страница 14: ...ekt wk adu osady kamienia wapiennego wymiana wk adu armatura cieknie defekt wk adu wymiana wk adu za niska temperatura ciep ej wody z e ustawienie ograniczenia ciep ej wody ustawi poprawnie ograniczen...

Страница 15: ...a 1 6MPa 1 MPa 10 147 PSI 80 C 65 C 150 16 G 20 0 3 MPa 15 0 15MPa DIN EN 1717 3 1 33092000 1 1 96338000 2 96656000 3 96690000 4 92730000 5 96059000 6 96467000 7 S 94140000 8 96429000 9 13956000 10 94...

Страница 16: ...eratura dell acqua fredda 10 C pressione 0 3 MPa limitaci n del agua caliente temperature del agua caliente 60 C temperatura del agua fria 10 C presi n dinamica 0 3 MPa Warmwaterbegrenzing Warmwaterte...

Страница 17: ...da calcare con un semplice strofinamento E QuickClean la funci n de limpieza manual permite quitar la cal simplemente frotando los ejectores NL Met QuickClean de handmatige reinigings funktie kunnen...

Отзывы: