English
Attention!
The fitting must be installed, flushed
and tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and
cold water supply should be balanced.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water, swivel to the right =
cold water.
33144000/33143000: The flow is changed from
bath to shower function by pulling the knop at the
upper side of the spout. After shutting off the water
flow, the mixer returns automatically to the bath
function.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure: 0.1 - 0.5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
max. 80° C
Recommended hot water temp.:
65° C
Centre distance:
150 ± 16 mm
Connections G ½":
cold right -
hot left
Rate of flow 0.3 MPa:
approx. 20 l/min
Back flow and vacuum breaker
Hansgrohe single lever mixers can be used tog-
ether with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0.15 MPa.
To adjust the hot water limiter on single lever
mixers, please see page 15.
No adjustment is necessary when using a conti-
nuous flow water heater.
Attention!
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).
Spare parts
(see page 3)
1
handle
33092000
1.1 screw cover
96338000
2
flange
96656000
3
nut
96690000
4
cartridge, assy
92730000
5
locking screw
96059000
6
escutcheon Ø 68 mm
96467000
7
ball S - unions (2)
94140000
8
noise reduction (2)
96429000
9
aerator cpl. (10)
13956000
10 selector assy
94077000
11 diverter knob
96466000
12 non return valve DW 15 (10) 94074000
13 hose connection
96044000
Fault
Cause
Remedy
Insufficient water
- Shower filter seal dirty
- Filters dirty
- Non return ralve didn't move
back
- Clean filter seal between sho-
wer and hose
- Clean the filter/exchange filter
- Exchange non return valves
Mixer stiff
- Cartridge defective
- Exchange cartridge
Mixer dripping
- Cartridge defectiveSedimentati-
on
- Exchange cartridge
Hot water temperature too low
- Hot water limiter incor-rectly set - Set hot water limiter
Instantaneous heater didn't work - Flow limiter in handshower isn't
removed
- Filter are dirty
- Non return valve didn't move
back
- Remove flow limiter
- Clean the filter/exchange filter
- Exchange non return valves
6