Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Regulator filter dirty
- Clean filter in front of the mixer
and on the MTC-thermo cartridge
- Shower filter seal dirty
- Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
- Backflow preventers dirty or
leaking
- Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
- thermo cartridge calcified
- Exchange thermo cartridge
- For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
- Install function block turned
through 180º
Safety stop button not operating
- Spring defective
- Clean spring and/or button,
exchange if necessary
- Button calcified
Assembly
(see page 62)
7
Содержание ShowerSelect 15760 0 Series
Страница 25: ...42 C 65 C 180 180 62 25...
Страница 27: ...42 65 180 62 27...
Страница 41: ...42 C 65 C 180 180 62 41...
Страница 53: ...42 C 65 C 180 180 62 53...
Страница 56: ...42 65 180 180 62 56...
Страница 61: ...1 42 C 65 C 180 Safety Stop 62 61...
Страница 62: ...3 62 5 2 1 4 1 S 3 W 4 mm 5 Nm 4 2 2 2 1 SW 5 mm 1 2 1 0180018X...
Страница 64: ...64 11 CLICK 10 2 1...
Страница 66: ...66 5 2 1 4 z B 42 C for example 42 C 3 1 2 2 1 2 1...
Страница 68: ...68 5 1 2 3 4 3 mm SW 4 2 1 1 2...