> 50 l/min
Quattro
Trio
Raindrain
X
Center shower tub
English
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Children as well as adults with physical, mental
and/or sensoric impairments must not use this
shower system without proper supervision. Persons
under the influence of alcohol or drugs are prohibi-
ted from using this shower system.
Do not allow the streams of the shower touch sen-
sitive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
Installation Instructions
The fitting must be installed, flushed and tested after
the valid norms!
Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer’s indications of the dowel
manufacturer have to be taken into account.
This mixer cannot be used in conjunction with
hydraulically, electronically or thermally controlled
instantaneous heaters.
Technical Data
Operating pressure:
max. 0,6 MPa
Recommended operating pressure:
0,1 – 0,4 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
•
•
•
Assembly see page 31
Warm water
Cold water
Do not use silicone containing acetic acid!
The wall must be reinforced in this area.
Shut off valve
Quattro 4-Way Diverter Valve
Trio 2-Way Diverter Valve with integrated
Shut-off valve
Plug the unused outlet.
The waste drain performance must be more
than 50 l/min.
Waste
Dimensions
(see page 31)
Flow diagram
(see page 33 + 35)
Spare parts
(see page 38)
Cleaning
(see page 39)
Содержание Raindance E
Страница 31: ...31 Rainflow Rain Rainflow ...
Страница 32: ...32 High Flow Rain Flow DN 70 Raindrain 60067000 50 l min iBox universal 01800180 Rain Trio ...
Страница 33: ...33 Raindance E 150 3 Rain 1 Rain 2 Rainflow ...
Страница 34: ...34 High Flow Rain Flow DN 70 Raindrain 60067000 50 l min iControl iBox universal 01800180 Rain ...
Страница 35: ...35 Raindance S 150 3 Rain 1 Rain 2 Rainflow ...
Страница 36: ...36 Silikon 1 2 1 2 2 A B C 1 2 3 4 ...
Страница 37: ...37 1 2 3 5 6 8 7 ...
Страница 38: ...38 16x2 18x2 11x2 98513000 96525000 M5x6 96762000 95474000 95475000 96454000 98793000 13595000 ...
Страница 39: ...39 1 2 3 SW 5 mm 2 Nm SW 5 mm 1 2 2 1 ...
Страница 40: ...40 4 5 3 6 ...
Страница 42: ...42 ...
Страница 43: ...43 ...