4
Ceiling mount see page 38
Wall mount see page 36
Test certificate
(see page 44)
Spare parts
(see page 39)
Cleaning
(see page 40)
and
enclosed brochure
Flow diagram
(see page 31)
Dimensions
(see page 31)
Do not use silicone containing acetic acid!
Symbol description
Technical Data
Operating pressure:
max. 0,6 MPa
Recommended operating pressure:
0,1 - 0,4 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
Do not allow the streams of the shower touch
sensitive body parts (such as your eyes). An
adequate distance must be kept between the shower
and you.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms!
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels
are only suitable for concrete. For another wall
constructions the manufacturer‘s indications of the
dowel manufacturer have to be taken into account.
• The filter insert must be use to protect the shower
against incoming dirt by pipework. Incoming dirt leads
to defects or/and can damage parts of the shower;
such caused faults voids all liability and guarantee
claims.
English
Содержание Raindance AIR 27493000
Страница 13: ...13 38 36 44 39 40 31 31 0 6 MPa 0 1 0 4 MPa 1 MPa 10 bar 147 PSI 60 C 70 C 4...
Страница 14: ...14 38 36 44 39 40 31 31 Hansgrohe 0 6 0 1 0 4 1 10 bar 147 PSI 60 C 70 C 4...
Страница 22: ...22 38 36 44 39 40 31 31 Hansgrohe 0 6 MPa 0 1 0 4 MPa 1 MPa 10 bar 147 PSI 60 C 70 C 4 min O...
Страница 28: ...28 38 36 44 39 40 31 31 Hansgrohe 0 6 0 1 0 4 1 10 bar 147 PSI 60 C 70 C 4...
Страница 30: ...30 38 36 44 39 40 31 31 0 6 0 4 0 1 PSI 147 10 1 60 C 4 70 C...
Страница 31: ...31 Raindance 27471000 Raindance 27471000 Raindance AIR 27476000 Raindance AIR 27476000...
Страница 32: ...32 Raindance AIR 2746800 Raindance AIR 27468000 Raindance AIR 27474000 Raindance AIR 27474000...
Страница 33: ...33 Raindance AIR 27493000 Raindance AIR 27493000 27492000 Raindance AIR 27492000...
Страница 34: ...34 Raindance AIR 27478000 Raindance 27472000 Raindance 27472000 Raindance AIR 27478000...
Страница 35: ...35 Raindance AIR 27477000 Raindance AIR 27494000 Raindance AIR 27494000 Raindance AIR 27477000...
Страница 37: ...37 1 2 SW 2 mm 1 Nm 27471000 27474000 27476000 27468000 27492000 27493000 6 8 9 7 SW 10 mm 10 Nm...
Страница 40: ...40 4 5 6 1 min SW 17 mm SW 2 mm 1 2 3...
Страница 41: ...41 1 2 4 3 SW 5 mm SW 5 mm 2 Nm SW 17 mm 10 Nm 7 SW 2 mm 1 Nm 8...
Страница 42: ...42...
Страница 43: ...43...