2
English
Assembly
(see page 4)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Centre distance:
150±12 mm
Connections G 1/2:
cold right - hot left
Thermal disinfection:
70°C / 4 min
• The product is exclusively designed for drinking
water!
• Safety against backflow
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 6)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Maintenance
(see page 12)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions
(see page 8)
Flow diagram
(see page 8)
Spare parts
(see page 10)
XX = Colors
00 = Chrome Plated
14 = Brushed Bronze
Cleaning
(see page 7)
Operation
(see page 7)
Fault
Cause
Remedy
Insufficient water
- Aerator calcified, dirty
- Clean aerator, replace as necessary
- check valve hasn't moved back
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
- Hot water limiter incorrectly set
- Set hot water limiter
Instantaneous heater didn’t work
- Regulator filter dirty
- Clean the filter / exchange filter
- check valve hasn't moved back
- Exchange check valves
- Flow limiter in handshower isn’t
removed
- Remove flow limiter