background image

3

English

Assembly 

(see page 4)

 

Safety Notes

 

Gloves should be worn during installation to prevent crushing and cutting 

injuries.

 

The product may only be used for bathing, hygienic and body cleaning 

purposes.

 

Children as well as adults with physical, mental and/or sensoric impairments 

must not use this product without proper supervision. Persons under the 

influence of alcohol or drugs are prohibited from using this product.

 

The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport damages. After it has been 

installed, no transport or surface damage will be honoured.

• The pipes and the fixture must be installed, flushed and tested as per the 

applicable standards.

• The plumbing codes applicable in the respective countries must be observed.
• The product is not designed to be used with steam baths!

ECOSTAT in conjunction with flow heaters

• If fitting a hand shower remove the water limiter from the shower.
• If the continuous water heater causes any problems, or you have different
• When using the Ecostat with combination boilers, the Ecostop safety set 

(#95042000) has to be removed.

Technical Data

Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 70°C 

Recommended hot water temp.: 

65°C 

Centre distance: 

150±12 mm 

Connections G 1/2: 

cold right - hot left 

Thermal disinfection: 

max. 70°C / 4 min

• Safety against backflow
• The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!

Safety Function 

(see page 5)

The desired maximum temperature for example max. 42º C can be pre-set thanks 

to the safety function.

Adjustment 

(see page 5)

After the installation, the output temperature of the thermostat must be checked. A 

correction is necessary if the temperature measured at the output differs from the 

temperature set on the thermostat.
To adjust the hot water limiter. Using a hot water limiter in combination with a 

continuous flow water heater is not recommended.

ECOSTOP 

(see page 6)

Maintenance 

(see page 6)

• The check valves must be checked regularly according to DIN EN 1717 in 

accordance with national or regional regulations (at least once a year).

• To guarantee the smooth running of the thermostat, it is necessary from time to 

time to turn the thermostat from total hot to total cold.

Dimensions 

(see page 8)

Flow diagram 

(see page 8)

  Shower outlet

  Tub outlet

Spare parts 

(see page 10)

Cleaning 

(see page 9)

Operation 

(see page 7)

Fault

Cause

Remedy

Insufficient water

- Supply pressure inadequate

- Check water pressure (If a pump has been installed 

check to see if the pump is working).

- Regulator filter dirty (#96922000)

- Clean filter in front of the mixer and on the MTC-ther-

mo cartridge (#96922000)

- Shower filter seal dirty

- Clean filter seal between shower and hose

Crossflow, hot water being forced into cold water 

pipe, or vice versa, when mixer is closed

- Backflow preventers dirty or leaking

- Clean backflow preventers, exchange if necessary

Spout temperature does not correspond with 

temperature set

- Thermostat has not been adjusted

- Adjust thermostat

- Hot water temperature too low

- Increase hot water temperature to 42 ºC to 65 ºC

Temperature regulation not possible

- thermo cartridge calcified

- Exchange thermo cartridge

Instantaneous heater didn't work with thermostat

- Filters are dirty

- Clean the filter / exchange filter

- check valve hasn't moved back

- Exchange check valves

- Flow limiter in handshower isn’t removed

- Remove flow limiter

Shower or spout dripping

- Dirt or sedimentation on valve seat, shut-off unit dam-

aged

- Clean the filter / exchange filter

Содержание Ecostat 13201007

Страница 1: ...ZH 2 EN Instructions for use assembly instructions 3 Ecostat 13201007 Ecostat 13211007...

Страница 2: ...ous water heater causes any problems or you have different ECOSTOP 95042000 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 70 C 65 C 150 12 mm G 1 2 70 C 4 5 42 5 ECOSTOP 6 6 DIN EN 1717 8 8 10 9 7 96...

Страница 3: ...tment see page 5 After the installation the output temperature of the thermostat must be checked A correction is necessary if the temperature measured at the output differs from the temperature set on...

Страница 4: ...4 Silicone X 36 mm X 36 X max 39 mm max 5 mm 7 1 1 2 2 1 2 5 4 6 8 3b 3a 36 mm SW 24 mm SW 30 mm 17 Nm...

Страница 5: ...5 1 4 6 5 1 2 1 3 4 2 5 6 SW 3 mm SW 3 mm SW 3 mm 2 Nm 2 3 1 2 SW 3 mm 2 Nm 42 C for example 42 C...

Страница 6: ...6 1 2 4 3 5 6 SW 3 mm 10 l min for example 10 l min SW 3 mm 2 Nm 1 SW 30 mm 1 2 2 SW 10 mm 5 6 1 SW 30 mm 17 Nm 3 red SW 10 mm 20 Nm 4...

Страница 7: ...7 1 1 2 2 1 2 1 2 40 C 40 C cold open close hot open cold open close hot open...

Страница 8: ...6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 1 2 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9...

Страница 9: ...enter openings and gaps in the Hansgrohe products and cause damage After cleaning rinse thoroughly with clean water to remove any cleaner residue The use of steam cleaners is not permitted The high te...

Страница 10: ...467000 92836000 98674000 95433000 M4x14 SW 3 mm 96509000 98129000 16x2 92511000 M24x1 25 l min SW 22 mm 92836000 95433000 M4x14 SW 3 mm 94282000 95041000 94140007 SW 24 mm 96157000 SW 30 mm 96922000 9...

Страница 11: ...11...

Страница 12: ...Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 09 2019 9 04185 53...

Отзывы: