3
English
Assembly
(see page 4)
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The product may only be used for bathing, hygienic and body cleaning
purposes.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• The product is not designed to be used with steam baths!
ECOSTAT in conjunction with flow heaters
• If fitting a hand shower remove the water limiter from the shower.
• If the continuous water heater causes any problems, or you have different
• When using the Ecostat with combination boilers, the Ecostop safety set
(#95042000) has to be removed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Centre distance:
150±12 mm
Connections G 1/2:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function
(see page 5)
The desired maximum temperature for example max. 42º C can be pre-set thanks
to the safety function.
Adjustment
(see page 5)
After the installation, the output temperature of the thermostat must be checked. A
correction is necessary if the temperature measured at the output differs from the
temperature set on the thermostat.
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
ECOSTOP
(see page 6)
Maintenance
(see page 6)
• The check valves must be checked regularly according to DIN EN 1717 in
accordance with national or regional regulations (at least once a year).
• To guarantee the smooth running of the thermostat, it is necessary from time to
time to turn the thermostat from total hot to total cold.
Dimensions
(see page 8)
Flow diagram
(see page 8)
Shower outlet
Tub outlet
Spare parts
(see page 10)
Cleaning
(see page 9)
Operation
(see page 7)
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Regulator filter dirty (#96922000)
- Clean filter in front of the mixer and on the MTC-ther-
mo cartridge (#96922000)
- Shower filter seal dirty
- Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water
pipe, or vice versa, when mixer is closed
- Backflow preventers dirty or leaking
- Clean backflow preventers, exchange if necessary
Spout temperature does not correspond with
temperature set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to 42 ºC to 65 ºC
Temperature regulation not possible
- thermo cartridge calcified
- Exchange thermo cartridge
Instantaneous heater didn't work with thermostat
- Filters are dirty
- Clean the filter / exchange filter
- check valve hasn't moved back
- Exchange check valves
- Flow limiter in handshower isn’t removed
- Remove flow limiter
Shower or spout dripping
- Dirt or sedimentation on valve seat, shut-off unit dam-
aged
- Clean the filter / exchange filter
Содержание Ecostat 13201007
Страница 1: ...ZH 2 EN Instructions for use assembly instructions 3 Ecostat 13201007 Ecostat 13211007...
Страница 4: ...4 Silicone X 36 mm X 36 X max 39 mm max 5 mm 7 1 1 2 2 1 2 5 4 6 8 3b 3a 36 mm SW 24 mm SW 30 mm 17 Nm...
Страница 5: ...5 1 4 6 5 1 2 1 3 4 2 5 6 SW 3 mm SW 3 mm SW 3 mm 2 Nm 2 3 1 2 SW 3 mm 2 Nm 42 C for example 42 C...
Страница 7: ...7 1 1 2 2 1 2 1 2 40 C 40 C cold open close hot open cold open close hot open...
Страница 11: ...11...