background image

 

© Galvin Engineering Pty Ltd 

 

Product Installation Guidelines 

Document No.: 001.00.10.18 

 

Version 1, 4 November 2022, Page 

1

 of 

4

 

 
 
CliniLever

®

 CP-BS Hospital Wall Top Assembly 

 

PRODUCT CODES: 

 

 

TCWTC150CC    

TCWTC150HC 

TCWTC80CC      

TCWTC80HC 

TCWTJ150CC     

TCWTJ150HC 

TCWTJ80CC       

TCWTJ80HC 

 

SPECIFICATIONS

 

 

The Galvin Specialised CliniLever

®

 product range is primarily used for hand washing applications in 

hospitals, aged care facilities, schools and in-home care. 

 

CliniLever

®

 products provide state of the art features to comply with the latest healthcare guidelines.  

 

The dual levers for on/off, hot and cold temperature have a straight forward operation which simplifies 
hand washing. 

 

Our highly sought after lever handle design can easily be operated with wrists or elbows. 

 

The main body is made of solid dezincification resistant (DR) brass rod, with a DR brass fixed outlet. 

 

Quick action SBA’s include brass jumper valve / ceramic cartridge components, with red and blue 
indicator buttons on 80mm/150mm lever action handles.

 

IMPORTANT:  All  CliniLever

®

  healthcare  taps  are  tested  in  accordance  with  AS/NZS  3718  and  leave  our 

premises in good working order.

 

 

TECHNICAL DATA

 

Inlet 

 

G 5/8

” BSP- Male 

Outlet  

N/A 

Headwork 

TCWTJ150CC, TCWTJ80CC, TCWTJ150HC, TCWTJ80HC 

Jumper Valve 

TCWTC150CC, TCWTC80CC, TCWTC150HC, TCWTC80HC 

Ceramic Disc 

Working Pressure Range (kPa)  

Min 

50 

Max 

500 

Working Temperature (°C) 

Min 

Max 

65 

Nominal Flow Rate (LPM) 

N/A 

Finish 

Chrome 

NOTE: Galvin Specialised continually strive to improve their products.  Specifications may change without notice.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for CliniLever TCWTC150CC

Page 1: ...Our highly sought after lever handle design can easily be operated with wrists or elbows The main body is made of solid dezincification resistant DR brass rod with a DR brass fixed outlet Quick action SBA s include brass jumper valve ceramic cartridge components with red and blue indicator buttons on 80mm 150mm lever action handles IMPORTANT All CliniLever healthcare taps are tested in accordance ...

Page 2: ...dance with AS NZS 3500 the PCA and your local regulatory requirements Water and or electrical supply conditions must also comply to the applicable national and or state standards Failing to comply with these provisions shall void the product warranty and may affect the performance of the product 1 Fit spindle assembly Remove handle and flange from spindle assembly Ensure jumper valve and fibre was...

Page 3: ... operation of the unit and inspect for any leaks TROUBLESHOOTING PROBLEM CAUSE RECTIFICATION Taps are dripping water Jumper valves are worn or damaged Replace jumper valve Tap seat is damaged Refurbish tap seat using a reseating tool Water is leaking from spindle O ring on jumper valve spindle is damaged or worn Replace o ring Water is not flowing from tap Water is turned off Turn on water Aerator...

Page 4: ...pect to the product Galvin Engineering Pty Ltd makes no other warranties express or implied Galvin Engineering Pty Ltd hereby specifically disclaims all other warranties express or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Galvin Engineering Pty Ltd products are covered under our manufacturer s warranty available for downloa...

Reviews: