Hans Grohe Ecostat 1001 SL Care 13284000 Скачать руководство пользователя страница 5

4

5

Technical Data

Ecostat 1001 SL Care

This thermostatic valve will suit supplies of:

HIGH PRESSURE (HP-S)

Operating pressure:                         max. 10 bar 

Recommended operating pressure:      0.2 - 5 bar 

Test pressure:                                          16 bar 

Hot water temperature:                       max. 80°C 

Recommended hot water temp.:                  65°C 

Rate of flow from bath spout:    20 l/min. @ 3 bar 

Rate of flow from shower outlet:18 l/min. @ 3 bar 

Maximum outlet temperature:               43°C +/-*

Safety check:                                            40°C 

Hot water connection:                           Left hand 

Cold water connection:                       Right hand 

Minimum difference between hot 

water and mixed water temperature:               6 K

Hot and cold supply pressure should be balanced

Operating pressure range                          High pressure                       Low pressure

Maximum static pressure - bar                               10                                             10

Flow pressure, hot and cold - bar                           1 to 5                                        0.2 to 1

Hot supply temperature - °C                                  52 to 65                                    52 to 65

Cold supply temperature - °C                                5 to 20                                      5 to 20

Mixed water temperature

Application                   Mixed water temperature

                                        (at point of discharge)

Bidet                                                38°C max.

Shower                                            41°C max.

Washbasin                                       41°C max.

Bath (44°C fill)                                  44°C max.

Bath (46°C fill)                                  46°C max.

*  For  preset  outlet  temperature  adjustment  –  See 

page 9 „Commisioning“.

NB. 

If  a  water  supply  is  fed  by  gravity  then  the 

supply  pressure  should  be  verified  to  ensure  the 

conditions  of  use  are  appropriate  for  the  valve. 

Valves operating outside of these supply conditions 

cannot  be  guaranteed  to  operate  as  a  TMV2  or 

TMV3 valve.

Supply Conditions TMV2

Supply Conditions TMV3

Operating pressure range                          High pressure                       Low pressure

Maximum static pressure - bar                               10                                             10

Flow pressure, hot and cold - bar                           1 to 5                                        0.2 to 1

Hot supply temperature - °C                                  55 to 65                                    55 to 65

Cold supply temperature - °C                                5 to 25                                      5 to 25

The following models are TMV3 approved for high 

pressure shower (HP-S) application: 13282000 

Содержание Ecostat 1001 SL Care 13284000

Страница 1: ...Installation Instructions Ecostat 1001 SL Care 13282000 Ecostat 1001 SL Care 13284000...

Страница 2: ...e tests 10 Frequency of in service tests 10 Thermostatic Adjustement Temperature Limitation 11 Operating your Shower 12 Cleaning 13 Spare Parts 14 15 Trouble Shooting 16 The Ecostat 1001 SL Care 13284...

Страница 3: ...ustry Approved Plumber Scheme WIAPS Dispose of plastic bags carefully Keep children well away from the work area Check for hidden pipes and cables in the wall before drilling holes The unit must be mo...

Страница 4: ...ith the following Ecostat 1001 SL Care 13282000 1 Ecostat 1001 SL 3 Escutcheons 2 Mesh washers 4 S unions 1 2 3 4 Ecostat 1001 SL Care 13282000 Ecostat 1001 SL Care 13284000 1 Ecostat 1001 SL 3 Escutc...

Страница 5: ...emperature C 52 to 65 52 to 65 Cold supply temperature C 5 to 20 5 to 20 Mixed water temperature Application Mixed water temperature at point of discharge Bidet 38 C max Shower 41 C max Washbasin 41 C...

Страница 6: ...int 1 0 10 bar Unvented System pressure balanced 1 0 10 bar Pumped System 1 0 10 bar IMPORTANT If you install this mixer with a gravity fed system there must be a minimum head vertical distance from t...

Страница 7: ...7 Unvented System pressure balanced Pumped System...

Страница 8: ...tape round the S unions and screw into the backplate elbows The S unions must protrude beyond the tiled surface between 32 and 41mm figs 2 3 4 Seal the gap between the S unions and the tiles fig 3 5...

Страница 9: ...e mixed water in accordance with the manufacturer s instructions and the requirement of the application and then carry out the following sequence a record the temperature of the hot and cold water sup...

Страница 10: ...nce of any other instruction or guidance on the means of determining the appropriate frequency of in service testing the following procedure may be used 1 6 to 8 weeks after commissioning carry out th...

Страница 11: ...he spindle and slide off the locking ring fig 1 2 Turn the spindle until the required maximum temperature is reached 43 C You will need to use a thermometer fig 2 3 Replace the locking ring back onto...

Страница 12: ...1001 SL Care Flow ON OFF Control Shower Turn the flow control handle fig 2a anti clockwise to turn the water on and to increase the flow for the shower outlet Turn it clockwise to decrease the flow a...

Страница 13: ...ing Instructions for Mixers and Showers Please follow the cleaning materials manufacturer s inistructions In addition pay attention to tlie following points Clean the mixers and showers as and when re...

Страница 14: ...ement 94282000 2 Shut off and diverter unit 96509000 3 Handle for shut off and diverter unit and temperature control 98664000 4 Check valve NV15 DN15 96737000 5 S unions 94140000 6 Escutcheon 96467000...

Страница 15: ...DN15 1 Thermostatic element 94282000 2 Shut off unit 94149000 3 Handle for shut off unit and temperature control 98664000 4 Check valve NV15 DN15 96737000 5 S unions 94140000 6 Escutcheon 96467000 7...

Страница 16: ...r or spout dripping Dirt in the flow valve or shut off Clean or replace shut off unit unit damaged Warranty You have purchased a quality product from Hansgrohe All parts which show any kind of fault a...

Отзывы: