Assembly see page 4

Spare parts 

(see page 10)

Cleaning 

(see page 9) and en-

closed brochure

Flow diagram  

(see page 8)

  Normal spray with EcoSmart

®

  Normal spray without EcoSmart

®

  Regular with EcoSmart

®

  Regular without EcoSmart

®

Dimensions 

(see page 8)

Operation 

(see page 7)

• Do not rotate the spout further than 360º 

or damage to the hose will result.

• Hansgrohe recommends not to use as 

drinking water the first half liter of water 
drawn in the morning or after a pro-
longed period of non-use.

Adjustment 

(see page 6)

To adjust the hot water limiter. Using a hot 
water limiter in combination with a continu-
ous flow water heater is not recommended.

Symbol description

 

Safety Notes

 

Gloves should be worn during installation to prevent 
crushing and cutting injuries.

 

The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 
surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be oberserved.

Technical Data

This mixer series-produced with EcoSmart

®

 

(flow 

limiter)
Operating pressure: 

max. 1 MPa

Recommended operating pressure: 

0,1 - 0,5 MPa

Test pressure: 

1,6 MPa

(1 MPa = 10 bar = 147 PSI)
Hot water temperature: 

max. 70°C

Recommended hot water temp.: 

65°C

Thermal disinfection: 

max. 70°C / 4 min

The product is exclusively designed for drinking water!

English

Do not use silicone containing acetic acid!

Maintenance 

(see page 9)

The check valves must be checked regularly 
according to DIN EN 1717 in accordance 
with national or regional regulations (at least 
once a year).

Содержание Cento XXL 14811000

Страница 1: ...EN Instructions for use assembly instructions 2 DE Gebrauchsanleitung Montageanleitung 3 Cento XXL 14811000 ...

Страница 2: ...The hot and cold supplies must be of equal pres sures Installation Instructions Prior to installation inspect the product for transport damages After it has been installed no transport or surface damage will be honoured The pipes and the fixture must be installed flushed and tested as per the applicable standards The plumbing codes applicable in the respective countries must be oberserved Technica...

Страница 3: ...e zwischen den Kalt und Warmwasseranschlüssen müssen ausgeglichen werden Montagehinweise Vor der Montage muss das Produkt auf Transportschä den untersucht werden Nach dem Einbau werden keine Transport oder Oberflächenschäden anerkannt Die Leitungen und die Armatur müssen nach den gülti gen Normen montiert gespült und geprüft werden Die in den Ländern jeweils gültigen Installationsrichtli nien sind...

Страница 4: ...4 1a 1b max 35 max 70 3 Nm SW 10 mm SW 24 mm 4 Nm 2 1 2 3 4 5 ...

Страница 5: ...5 1 Nm 2 min 6 7 8 9 10 ...

Страница 6: ...6 Justierung 2 1 3 4 5 6 7 60 C 10 C 0 3 MPa ...

Страница 7: ...7 1 2 click open öffnen open öffnen close schließen cold kalt hot warm ...

Страница 8: ...8 1 2 147 101 m a x 7 0 50 Ø 6 0 0 Ø 34 8 3 0 G 1 2 187 29 Ø 270 314 2 0 2 117 360 3 4 ...

Страница 9: ...9 Reinigung 1 1 2 2 Wartung ...

Страница 10: ...523000 95008000 98231000 18x1 5 97558000 98387000 17x2 5 92602000 20x2 5 98140000 20x1 98205000 21x2 97735000 95498000 97475000 95730000 95049000 98193000 32x2 98459000 97350000 97489000 900 mm SW 24 mm 97209000 M37x1 5 SW 30 mm 95140000 M4x20 SW 4 mm ...

Страница 11: ...11 ...

Страница 12: ...ichen Hansgrohe Auestraße 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 02 2017 9 02795 03 P IX DVGW SVGW ACS WRAS ETA 14811000 X ...

Отзывы: