6
6
6Safety6Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
6
The hot and cold supplies must be of equal pressu-
res.
6
14855000: Only dishwashers and washing
machines certified with the DVGW emblem may be
connected to the appliance connection valve without
an additional fuse. If no consumer is connected to
the appliance connection valve, it must be plugged.
Installation6Instructions
• The fitting must be installed, flushed and tested after
the valid norms!
Technical6Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
English
Operation6
(see page 34)
Spare6parts6
(see page 36)
XXX = Colors
000 = chrome plated
750 = alux
Flow6diagram6
(see page 33)
Dimensions6
(see page 32)
Assembly6see6page631
Do not use silicone containing acetic acid!
To adjust the hot water limiter on single lever
mixers, please see page 35. No adjustment
is necessary when using a continuous flow
water heater.
Symbol6description
Test6certificate6
(see page 33)
Cleaning
see enclosed brochure.
Fault
Cause
Remedy
Insufficient water
- Aerator calcified, dirty
- Clean aerator, replace as necessary
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping in area of swivel
spout
- O-ring defective
- Exchange O-ring
Water escaping at the threaded
base
- connection hoses not completely
screwed into basic body
- O-ring at the connection hose
defective.
- Tighten connection hoses by hand
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
4