6
6
6Safety6Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Installation6Instructions
• The fitting must be installed, flushed and tested after
the valid norms!
• Important!* With water heaters of 5 liters the flow rate
at the mixer should not exceed 5 l/min. In this case the
flow rate must be reduced at the isolation valve.
Technical6Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Rate of flow:
max. 5 l/min
anti-pollution function
English
Maintenance6
(see page 36)
• The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
• When changing the spray former, it is
imperative to use one made for this type
of mixer.
Cleaning6
(see enclosed brochure.)
Operation6
(see page 34)
When the storage tank is being heated, the
spout will drip.
Assembly6see6page631
Test6certificate6
(see page _1u)
Dimensions6
(see page 33)
Fault
Cause
Remedy
Insufficient water
-
Spray former calcified, dirty
-
Clean spray former, exchanging if
necessary
-
Filter at the isolation valves soils.
-
Clean the filter / exchange filter
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping constantly with water
heater switched off
-
Cartridge defective
-
Exchange cartridge
Water escaping in area of swivel
spout
-
O-ring defective
-
Exchange O-ring
Water escaping at the threaded base
-
Adapter floor leaks
-
Check the adapter floor, replace if
necessary
-
O-ring at the connection hose
defective.
-
Exchange O-ring
Water escaping bels ow handle
-
Cartridge defective
-
Exchange cartridge
Water run out below the skin
-
The connection of the hanspray is
not tighten
-
Tighten the connection
-
Hose have a defect
-
Exchange the hose
Do not use silicone containing acetic acid!
Symbol6description
Spare6parts6
(see page 35)
4
Содержание AXOR Steel 35813800
Страница 14: ...6 6 6 6 5 5 1 MPa 0 1 0 5MPa 1 MPa 10 bar 147 PSI 80 C 65 C 5 36 DIN EN 1717 34 31 _1u 33 O O O O 35 13...
Страница 15: ...6 6 6 6 5 5 1 0 1 0 5 1 10 bar 147 PSI 80 C 65 C 5 36 DINEN1717 34 31 _1u 33 35 14...
Страница 23: ...6 6 6 6 5 5 1 MPa 0 1 0 5MPa 1 MPa 10 bar 147 PSI 80 C 65 C 5 l min 36 DIN EN 1717 DIN 1988 34 31 _1u 33 35 22...
Страница 29: ...6 6 6 6 5 5 1 0 1 0 5 1 10 bar 147 PSI 80 C 65 C 5 36 DIN EN 1717 DIN 1988 34 31 _1u 33 O O O O 35 28...
Страница 31: ...31 U U 5 5 1 0 1 0 5 1 10 147 PSI 80 C 65 C 5 33 _ 1 u 35 34 36 DIN EN 1717 DIN 1988 30...
Страница 32: ...31 2 3 1a 1b SW 10 mm SW 19 mm 4 5 7 Nm...
Страница 34: ...33 Steel 35813800...