background image

4

i

Assembly see page 34

Fault

Cause

Remedy

Insufficient water

 

-

Supply pressure inadequate

 

-

Check water pressure (If a pump has been installed 
check to see if the pump is working).

 

-

Regulator filter dirty

 

-

Clean filter in front of the mixer and on the MTC-
thermo cartridge

 

-

Shower filter seal dirty

 

-

Clean filter seal between shower and hose

Crossflow, hot water being forced into cold water pipe, 
or vice versa, when mixer is closed

 

-

Backflow preventers dirty or leaking

 

-

Clean backflow preventers, exchange if necessary

Spout temperature does not correspond with tempera-
ture set

 

-

Thermostat has not been adjusted

 

-

Adjust thermostat

 

-

Hot water temperature too low

 

-

Increase hot water temperature to 42 ºC to 65 ºC

Temperature regulation not possible

 

-

Temperature regulator dirty or calcified

 

-

Clean temperature regulator, exchange if necessary

Safety stop button not operating

 

-

Spring defective

 

-

Clean spring and/or button, exchange if necessary

 

-

Button calcified

Valve stiff

 

-

Select stop valve DN9 damaged

 

-

Exchange Select stop valve DN9

Shower or spout dripping

 

-

Select stop valve DN9 damaged

 

-

Exchange Select stop valve DN9

Pushbutton cannot be actuated or is without function

 

-

Safety guard of isolating valve has not been removed  

-

Remove safety guard from isolating valve

Pushbutton is jammed or stiff

 

-

Seal needs greasing

 

-

Grease the seal

Pushbutton does not snap in

 

-

Select Adapter incorrectly trimmed

 

-

Trim and mount Select Adapter according to Fig. 7 
(see page 34)

 

-

First, fully press the pushbutton down into the rosette; 
then, mount the rosette

Test certificate 

(see page 44)

Cleaning 

(see enclosed brochure)

Dimensions 

(see page 31)

Spare parts 

(see page 42)

Colors

000 = chrome plated

610 = black

Maintenance 

(see page 40)

• The mixer is equipped with check valves. The check valves must be 

checked regularly according to DIN EN 1717 in accordance with 
national or regional regulations (at least once a year).

• To guarantee the smooth running of the thermostat, it is necessary 

from time to time to turn the thermostat from total hot to total cold.

Operation 

(see page 39)

Minor leaking may occur briefly during initial commissioning and inter-
ruption/restart of the water supply.

Adjustment 

(see page 38)

After the installation, the output temperature of the thermostat must be 
checked. A correction is necessary if the temperature measured at the 
output differs from the temperature set on the thermostat.

Safety Function 

(see page 38)

The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.

Installation example 

(see page 32)

Do not use silicone containing acetic acid!

Symbol description

English

 

Safety Notes

 

Gloves should be worn during installation to prevent crushing and cutting 
injuries.

 

The product may only be used for bathing, hygienic and body cleaning pur-
poses.

 

Children as well as adults with physical, mental and/or sensoric impairments 
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.

 

The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport damages. After it has been 

installed, no transport or surface damage will be honoured.

• The pipes and the fixture must be installed, flushed and tested as per the applica-

ble standards.

• The plumbing codes applicable in the respective countries must be observed.

Special information for UK 

If installing this product with a pump, please be aware that it has to have negative 
head switching. This product will not function with a positive head pump..

Technical Data

Operating pressure: 

max. 1 MPa

Recommended operating pressure: 

0,1 - 0,5 MPa

Test pressure: 

1,6 MPa

(1 MPa = 10 bar = 147 PSI)
Hot water temperature: 

max. 70°C

Recommended hot water temp.: 

65°C

Thermal disinfection: 

max. 70°C / 4 min

Safety against backflow

The product is exclusively designed for drinking water!

Flow diagram 

(see page 31)

  Outlet 1

  Shower outlet

Содержание Axor Shower Select 36712000

Страница 1: ...itie Mont ny n vod 12 ZH 13 RU 14 HU Haszn lati tmutat Szerel si tmutat 15 FI K ytt ohje Asennusohje 16 SV Bruksanvisning Monteringsanvisning 17 LT Vartotojo instrukcija Montavimo instrukcijos 18 HR...

Страница 2: ...immung mit nationalen oder regionalen Bestimmungen DIN 1988 einmal j hrlich auf ihre Funktion gepr ft werden Um die Leichtg ngigkeit der Regeleinheit zu gew hrleisten sollte der Thermostat von Zeit zu...

Страница 3: ...ent la norme EN 1717 ou conform ment aux dispositions nationales ou r gionales quant leur fonction au moins une fois par an Pour assurer le mouvement facile de l l ment thermostatique le thermostat de...

Страница 4: ...once a year To guarantee the smooth running of the thermostat it is necessary from time to time to turn the thermostat from total hot to total cold Operation see page 39 Minor leaking may occur briefl...

Страница 5: ...eno una volta all anno Per garantire la scorrevolezza dell elemento di regolazione di tanto in tanto si dovrebbe regolare il termostatico passando da tutto caldo a tutto freddo Procedura vedi pagg 39...

Страница 6: ...ra garantizar el funcionamiento duradero del termostato el mando del mismo deber a girarse de vez en cuando del extremo fr o al extremo caliente Manejo ver p gina 39 Se pueden producir ligeras salidas...

Страница 7: ...enminste een keer per jaar Om het soepel lopen van de regeleenheid te garanderen moet de thermostaat van tijd tot tijd op heel koud en heel warm worden ingesteld Bediening zie blz 39 Bij het eerste ge...

Страница 8: ...renstemmelse med nationale regler afpr ves regelm ssigt mindst en gang om ret For at sikre optimal funktion af termostaten b r termostaten fra tid til anden motioneres stilles skiftevis helt varm og h...

Страница 9: ...nti retorno As v lvulas anti retorno devem ser verificadas regularmente de acordo com a DIN EN 1717 segundo os regulamentos nacionais ou regionais pelo menos uma vez por ano Para garantir um funcionam...

Страница 10: ...abezpieczenia przed przep ywem zwrotnym Dzia anie zabezpiecze przed przep ywem zwrotnym zgodnie z norm DIN EN 1717 i miejscowymi przepisami musi by kontrolowane DIN 1988 raz w roku Aby zachowa atwo ob...

Страница 11: ...vybaven omezova em zp tn ho toku U zp tn ch ventil se mus podle DIN EN 1717 v souladu s n rodn mi nebo regi on ln mi p edpisy testovat jejich funk nost alespo jednou ro n Aby byl zaji t n lehk chod re...

Страница 12: ...loch sa mus pod a DIN EN 1717 v s lade s n rodn mi alebo region lnymi predpismi testova ich funk nos aspo raz ro ne Aby bol zaisten ahk chod regula nej jednotky mal by sa termostat z asu as nastavi na...

Страница 13: ...13 i 34 42 C 65 C Select DN9 Select DN9 Select DN9 Select DN9 7 34 44 31 42 000 610 40 DIN EN 1717 39 38 38 42 32 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 70 C 65 C 70 C 4 31 1...

Страница 14: ...Select DN9 Select DN9 Select DN9 Select DN9 Select Adapter Select Adapter 7 34 44 31 42 000 610 40 DIN EN 1717 39 38 Safety Function 38 Safety Function 42 C 32 1 0 1 0 5 1 6 1 10 bar 147 PSI 70 C 65...

Страница 15: ...tl val van felszerelve A visszafoly sg tl k m k d se a DIN EN 1717 szabv nynak megfele l en a nemzeti vagy ter leti rendelkez sekkel sszhangban vente egyszer ellen rizend Ahhoz hogy a szab lyoz egys...

Страница 16: ...staatti on varustettu vastaventtiileill Vastaventtiilien toiminta on tarkastettava s nn llisesti paikallisten ja kansallisten m r ysten mukaisesti DIN 1988 kerran vuodessa S t yksik n kevytk ytt isyyd...

Страница 17: ...regionala best mmelser DIN 1988 en g ng per r i enlighet med DIN EN 1717 F r att garantera att termostaten ej kalkar igen ska den regelbundet en g ng per vecka konditioneras Det sker genom att man n g...

Страница 18: ...reguliariai ma iausiai kart per metus pagal DIN 1988 pagal DIN EN1717 arba pagal galiojan ias nacionalines arba regionines normas Tam kad b t garantuotas tolygus temperat ros reguliavimas ir ilgas nau...

Страница 19: ...vati prema standardu DIN EN 1717 i u skladu sa va e im propisima najmanje jednom godi nje Kako bi se olak ala prohodnost i produljio vijek trajanja regulacijske jedinice potrebno je s vremena na vrije...

Страница 20: ...r d zenli olarak kontrol edilmelidir en az y lda bir kez Ayar nitesinin kolay hareket etmesini sa lamak i in termostat belirli aral klarla tamamen s cak ve so uk konuma getirilmelidir Kullan m bak n z...

Страница 21: ...tre inere vezi pag 40 Termostatul este dotat cu supape antiretur Supapele de re inere trebuie verificate regulat conform DIN EN 1717 i standardele na io nale sau regionale anual conform DIN 1988 Pentr...

Страница 22: ...9 Select DN9 Select DN9 Select DN9 To Select Adapter Select 7 34 44 31 42 000 610 40 DIN EN 1717 DIN 1988 39 38 Safety Function 38 Safety Function 42 C 32 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PS...

Страница 23: ...kladu z DIN EN 1717 in skladno z dr avnimi in regionalnimi dolo ili DIN 1988 enkrat letno redno testirati Da bi zagotovili gladko delovanje enote za uravnavanje je potreb no termostat ob asno nastavit...

Страница 24: ...giklappidega Tagasil giklap pide toimimist tuleb koosk las riiklike ja regionaalsete m rustega regulaarselt kontrollida vastavalt standardile DIN EN 1717 DIN 1988 kord aastas Termostaadi hea toimimis...

Страница 25: ...r nacion lajiem vai viet jiem noteikumiem DIN 1988 vienreiz gad Lai nodro in tu regulatora nevainojamu darb bu termostatu laiku pa laikam j iestata uz maksim li aukstu un maksim li karstu deni Lieto a...

Страница 26: ...atnog ventila se mora redovno proveravati prema standardu DIN EN 1717 i u skladu s va e im nacionalnim ili regionalnim propisima DIN 1988 jednom godi nje Kako bi se olak ala prohodnost i produ io vek...

Страница 27: ...rre Funksjonen til returl ps sperren skal iht DIN EN 1717 og i samsvar med de nasjonale og lokale forskrifter sjekkes regelmessig DIN 1988 en gang i ret For holde regulerings enheten bevegelig skal te...

Страница 28: ...65 C Select DN9 Select DN9 Select DN9 Select DN9 Select Select 7 34 44 31 42 000 610 40 DIN EN 1717 DIN 1988 39 38 Safety Function 38 Safety Function 42 C 32 1 0 1 0 5 1 6 1 10 bar 147 PSI 70 C 65 C...

Страница 29: ...drejtim t kund rt Penguesit e rrjedhjes n drejtim t kund rt duhen kontrolluar rregullisht n baz t normave DIN EN 1717 konform normave nacionale dhe regjionale DIN 1988 nj her n vit P r t leht suar p...

Страница 30: ...30 i 34 42 65 DN9 Select DN9 Select DN9 Select DN9 Select Select Adapter Select Adapter 34 7 44 31 42 000 610 40 DIN EN 1717 DIN 1988 39 38 38 42 32 1 0 5 0 1 1 6 PSI 147 10 1 70 C 65 C 4 70 C 31 1...

Страница 31: ...5 5 54 82 4 4 4 6 188 167 15 5 7 7 94 bar 0 6 12 18 24 30 36 42 48 MPa 0 0 2 0 4 0 6 0 8 Q l min Q l sec 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0...

Страница 32: ...1 2 DN 20 3 4 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q...

Страница 33: ...5 1 2 DN 15 1 2 DN 15 1 2 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0...

Страница 34: ...34 2 3 1 2 3 4 5 SW 4 mm 5 Nm SW 10 mm 6 7 8 9 10 SW 10 mm 1 2 0 mm 0 mm 1 2 2 1 2 01800180 1 1 3 SW 10 mm...

Страница 35: ...35 2 1 21 16 max 5 SW 4 mm SW 4 mm 5 Nm 7 mm 0 12 13 14 15 16 17 19 20 11 18 22 X 21...

Страница 36: ...36 2 2 1 1 X 11 X 2 mm 1 2 mm X 0 1 Nm 23 24 25 26 27 28 29 30 31 60 mm 6 mm 32 0 1 Nm 33 34 1 2 3...

Страница 37: ...37 40 C 40 C 40 C 40 C 40 C 40 C 40 C 40 C 40 C 1 2 2 1 3 SW 10 mm 6 Nm 35 38 37 39 40 42 43 44 45 SW 8 mm 4 Nm 1 2 N r 1 0 4 7 6 2 2 0 A r m a t u r e n f e t t G r e a s e 1 Nm 2 1 2 1 41 36...

Страница 38: ...38 40 C 40 C 40 C 1 2 40 C 1 2 40 C SW 3 mm 1 Nm 40 C z B 42 C for example 42 C 40 C 40 C 40 C 1 2 3 2 2 1 1 40 C 1 2 40 C 40 C 1 2 3 4 SW 3 mm 5 6 7 8 9 z B 42 C for example 42 C...

Страница 39: ...lo kuum karsts topla varm i ngroht Bedienung ffnen Schlie en Warm Kalt Reinigung kalt froid cold freddo fr o koud koldt fria zimna studen studen hideg kylm kallt altas Hladno so uk rece mrzlo k lm auk...

Страница 40: ...SW 4 mm 40 C 2 1 40 C SW 8 mm 40 C 40 C 40 C 2 1 1 2 3 4 5 6 SW 10 mm 7 40 C 2 1 3 SW 4 mm 5 Nm SW 10 mm 6 Nm 8 9 10 11 12 1 2 SW 27 mm SW 27 mm 8 Nm 0 1 Nm 13 40...

Страница 41: ...40 C 40 C SW 8 mm 4 Nm 1 Nm 2 1 40 C 40 C 1 2 40 C 40 C 1 2 14 15 16 17 1 19 20 40 C 18 41...

Страница 42: ...8156000 36x2 94073000 98197000 20x1 5 98123000 10x1 5 98282000 98146000 25x1 5 92146000 25x2 5 92298000 92299000 92544610 92544610 95531000 96454000 M5x55 95521000 1 98133000 16x2 98385000 11x1 5 1358...

Страница 43: ...43...

Страница 44: ...9 04763 03 Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 44 PA IX DVGW SVGW ACS WRAS KIWA ETA 3671...

Отзывы: