0 4
EN
A S S E M B L Y (see page 31)
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
Children as well as adults with physical, mental and⁄or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ The product is not designed to be used with steam baths!
T H E R M O S T A T I C M I X E R I N C O N J U N C T I O N W I T H C O M -
B I N A T I O N B O I L E R S
⁄ If the continuous water heater causes any problems, or you have different water
pressures you must install a water limiter to the cold supply, (ordered separately,arti-
cle number 97510000).
⁄ If fitting a hand shower remove the water limiter from the shower.
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Centre distance:
150±12 mm
Connections G 1⁄2:
cold right - hot left
Thermal disinfection:
max. 70°C ⁄ 4 min
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 32)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
S A F E T Y F U N C T I O N (see page 32)
The desired maximum temperature for example max. 42º C can be pre-set
thanks to the safety function.
M A I N T E N A N C E (see page 33)
⁄ The check valves must be checked regularly according to DIN EN 1717
in accordance with national or regional regulations (at least once a year).
⁄ To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
D I M E N S I O N S (see page 34)
F L O W D I A G R A M (see page 34)
Shower outlet
Tub outlet
S P A R E P A R T S (see page 35)
XXX = Colors
000 = Chrome Plated
140 = Brushed Bronze
250 = Brushed Gold-Optic
300 = Polished Redgold
310 = Brushed Redgold
330 = Polished Black Chrome
340 = Brushed Black Chrome
800 = Stainless Steel Optic
820 = Brushed Nickel
930 = Polished Brass
950 = Brushed Brass
990 = Polished Gold-Optic
T E S T C E R T I F I C A T E (see page 35)
C L E A N I N G (see page 36)
O P E R A T I O N (see page 33)
F A U L T
C A U S E
R E M E D Y
⁄ Insufficient water
⁄ Supply pressure inadequate
⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Regulator filter dirty
⁄ Clean filter in front of the mixer and on the MTC-thermo car-
tridge
⁄ Shower filter seal dirty
⁄ filter insert shower dirty
⁄ Clean filter seal between shower and hose
⁄ Clean filter insert between shower and hose
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Backflow preventers dirty or leaking
⁄ Clean backflow preventers, exchange if necessary
⁄ Spout temperature does not correspond with temperature
set
⁄ Thermostat has not been adjusted
⁄ Adjust thermostat
⁄ Hot water temperature too low
⁄ Increase hot water temperature to 42 ºC to 65 ºC
⁄ Temperature regulation not possible
⁄ thermo cartridge calcified
⁄ Exchange thermo cartridge
⁄ Instantaneous heater didn't work with thermostat
⁄ Filters are dirty
⁄ Clean the filter ⁄ exchange filter
⁄ check valve hasn't moved back
⁄ Exchange check valves
⁄ Flow limiter in handshower isn’t removed
⁄ Remove flow limiter
⁄ Shower or spout dripping
⁄ Dirt or sedimentation on valve seat.
⁄ Clean or exchange shut-off unit